CARD NAME
PN-CP15
RUN lamp is not
(FP)
flashing
PN-PW00
RUN lamp is not
(EXTPWR)
on
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of FP card
–48 V power is not
being supplied
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the mounting slot of the FP
1
card. (PIM2, 4, 6: slot 12)
Check the setting of SENSE switch.
2
1: PIM2
2: PIM4
3: PIM6
0, 4-F: Not used
Reset the MB switch.
3
(Down Up Down)
Check to see if the BUS cable
4
between each PIM is properly
connected.
If the fault cannot be cleared,
5
replace the card.
Confirm the lamp indication of
1
PZ-PW121/PZ-PW126 all lamps.
If the fault cannot be cleared,
2
replace the PN-PW00 card.
If the PZ-PW121/PZ-PW126 lamp
3
has abnormal condition, replace the
PZ-PW121/PZ-PW126 card.