4. Diagnostics and error handling
CPX error
Description of possible causes
number
17
Incorrect I/O length
CPX system start with setting "Stored
parameters" and CTEL master module in
operating mode "Automatic configura-
tion"
24
Process variable range underflow
25
Process variable range overflow
Parameter error
29
Invalid parameters received from the
host
Parameter error
Missing parameters
Changed parameter
39
Maintenance required
Short circuit at I-port (PS/PL supply or
56
communication signal)
57
I-port device missing/failed
58
I-port configuration error
Tab. 4/3:
Diagnostics/error messages by CPX error numbers
Festo P.BE-CPX-CTEL-EN en 1205NH
Error handling
•
Use system setting "Standard para-
meter" at the start of the CPX terminal
•
Process data inconsistent, check
•
Process data inconsistent, check
•
Check parameterisation
•
Check data sheet and values
•
Check data sheet
•
Check configuration
•
Cleaning
•
Refill
•
Replace worn parts
•
Check installation
•
Check configuration
•
Check configuration
4-7