Additional Notes
All defined users are deleted and the admin password is reset to the factory default
when you reset the camera using Admin Menu > Reset. Use start option 3 as described
in Section 3.2.4, «Start Options of the Camera».

3.7.4 Activating Event Control and Motion Detection

In its default configuration, the camera's event control and video motion detection features
are not enabled. In order to activate event-controlled recording, open Setup Menu > General
Event Settings and activate the Arming switch. Another method is to click on the Arm &
Record softbutton in the browser's user interface. The camera displays the motion detection
window in the live image (dotted frame in the center) and the camera automatically stores
images as soon as the motion detection window detects movements.

3.7.5 Deactivating Text and Logo Options

As camera arming is deactivated in the camera's default configuration (see preceding sec-
tion), the MOBOTIX camera only displays the text www.mobotix.Com, the time stamp
and the MOBOTIX logo at the top of the image. Once the camera arming has been activated,
the text at the bottom of the live image (event, action, messaging and recording symbols)
will also appear.
You can deactivate the status bar at the bottom of the live image and the text bar in the
top left-hand corner by setting Text Display in the Setup Menu > Text & Display Settings
dialog box to Off. Setting Text Display to Date and Time will only display the time stamp in
the live image. To hide the logo in the live image, open Admin Menu > Logo Profiles and
set Logo Display to Deactivated.

3.7.6 Deactivating the Camera Reboot

By factory default, the MOBOTIX camera automatically reboots once a week between 3 a.m.
and 4 a.m. The reason for this is that in some rare cases, external influences (for example,
radiation at high altitudes) can sometimes lead to camera malfunctions. The automatic
reboot will refresh the camera's memory and will ensure proper operation without requiring
any interaction on the part of the user. If desired, you can deactivate the automatic reboot
of the camera in the Admin Menu > Time Tasks dialog box.

3.7.7 Browser

Current Internet browsers (Internet Explorer, Mozilla Firefox, Safari, Google Chrome, Opera,
etc.) with enabled JavaScript can display the camera's live images with their standard settings.