Quickstart Description
4.
Check whether the current IP address is set within the address range
192.168.1.1 to 192.168.1.254. If not, change it accordingly.
Do not use IP address 192.168.1.100!
Do not use the IP address 192.168.1.100, however, as this network address is
reserved for the SPS in this example.
Figure 15: Properties of the TCP/IP Internet protocol
3.2.2.2
Assigning an IP address to the SPS
The IP address must occur in the network only once!
To ensure error-free network communication the IP addresses assigned to the PC
and to the SPS must be unique within the network!
In the event of an error, the error message "IP address configuration error" (error
code 6 - error argument 6) is indicated by the I/O LED at the next SPS power-on.
You can also use the address selection switch (DIP switch), Web-based
Management, DHCP, BootP or WAGO ETHERNET-Settings to assign an IP
address to the SPS.
The option using the address selection switch is described in this QuickStart
Guide. The other options are not described here, as these are explained separately
in the respective manuals for the „750-880 ETHERNET Programmable Fieldbus
750-880, -881, -882 ETHERNET Programmable Fieldbus
WAGO-I/O-SYSTEM 750
Quickstart Reference
Version 1.0.0