S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 2E:1:3:0x5000c50005961095 [DISK] ------------------------
Connector Location............................... external
Connector........................................ 2E
Enclosure........................................ 1
Bay.............................................. 3
WWID............................................. 0x5000c50005961095
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0KY280000980363WY
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 2E:1:4:0x5000c500052d0589 [DISK] ------------------------
Connector Location............................... external
Connector........................................ 2E
Enclosure........................................ 1
Bay.............................................. 4
WWID............................................. 0x5000c500052d0589
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0HEDC000097487BP2
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none