Verifying The Firmware Update - HP Smart Array -UX 11i v2 Support Manual

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

1.
Prepare to run saupdate from the Offline Diagnostics CD or the EFI partition:
To run saupdate from the Offline Diagnostic CD:
a.
b.
c.
d.
e.
To run saupdate from the EFI partition:
a.
b.
c.
IMPORTANT:
directory. If they are not, copy them to the EFI partition and run the saupdate from there.
2.
To update the firmware on the controller, use saupdate UPDATE:
To update a single enclosure, use this command:
saupdate UPDATE <seg:bus:dev:func:encl_index> <firmware_file>
For example, to update the enclosure at segment 0, bus 8, device 0, function 0, index
2 with the firmware file VWG2_206.S3:
fs0:\EFI\TOOLS> saupdate UPDATE 0:8:0:0:2 VWG2_206.S3
************************************************************************
************************************************************************
Updating Enclosure in Seg: 0, Bus: 8, Dev: 0, Func: 0, Index: 2
Current Enclosure Firmware version is 2.06
To update all attached enclosures, use this command:
saupdate UPDATE <seg:bus:dev:func> all_encl <firmware_file>

Verifying the firmware update

1.
After updating the firmware, cycle the power on the system and on any external JBODS
connected to the system.
32
Installing the controller
Download the firmware and copy it to the EFI partition.
Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before
booting the system.
Boot the system to the EFI Shell prompt.
Locate the cdrom entry in the list of mapped devices, and change to the device by
entering its associated fs number (for example, fs0) under EFI Shell prompt.
If the EFI utility and firmware image files are not located in the root directory, move
to the directory where these files are located, for example:
fs0:\> cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
Download the Smart Array EFI update utility saupdate.efi and copy it to the EFI
partition.
Download the firmware and copy it to the EFI partition.
Boot the system to the EFI Shell and change directories to the EFI partition.
The firmware image file and saupdate.efi must be located in the same
Smart Array Offline Firmware Update Utility
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
Sending Image Chunk No: 117 of 117
Activating firmware now, this may take several minutes.
Retrieving firmware version, this may take several minutes.
Version 2.07.09.02