HP Smart Array -UX 11i v2 Support Manual page 49

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

Example 3 Using saconfig to determine logical drive numbers
# saconfig /dev/ciss4
---------- LOGICAL DRIVE 0
Device File
= c4t0d0
RAID Level
= 0
Size
= 20479 MB
Stripe Size
= 128 KB
Status
= OK
Participating Physical Drive(s):
Ct
Enc
Bay
1E
1
9
0x500000e015141982
Participating Spare Drive(s):
None
---------- LOGICAL DRIVE 1 ----------
Device File
= c4t0d1
RAID Level
= 0
Size
= 20479 MB
Stripe Size
= 128 KB
Status
= OK
Participating Physical Drive(s):
Ct
Enc
Bay
1E
1
9
0x500000e015141982
Participating Spare Drive(s):
None
---------- LOGICAL DRIVE 2 ----------
Device File
= c4t0d2
RAID Level
= 0
Size
= 20479 MB
Stripe Size
= 128 KB
Status
= OK
Participating Physical Drive(s):
Ct
Enc
Bay
1E
1
9
0x500000e015141982
Participating Spare Drive(s):
None
Logical drive number.
1
In
Example
3, logical drives 0, 1, and 2 are located on the physical disk 0x500000e015141982.
To delete logical drive 1, you must delete logical drive 2. To delete logical drive 0, you must delete
logical drive 2, then delete logical drive 1.
If you delete a logical drive out of order, the command fails with an error:
1
----------
WWID
2
WWID
WWID
List of physical disks
2
participating in the logical
drive.
The saconfig configuration CLI
49

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart Array HP-UX 11i v2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smart array hp-ux 11i v3

Table of Contents