---- SAS/SATA DEVICE 3I:1:2:0x5000c500014aca69 [DISK] ------------------------
Connector Location............................... internal
Connector........................................ 3I
Enclosure........................................ 1
Bay.............................................. 2
WWID............................................. 0x5000c500014aca69
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0BCSS00009742GMA1
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. no
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 3I:1:1:0x5000c500014b6145 [DISK] ------------------------
Connector Location............................... internal
Connector........................................ 3I
Enclosure........................................ 1
Bay.............................................. 1
WWID............................................. 0x5000c500014b6145
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0AL1600009742GNNF
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. no
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no