Table 20 Smart Array controller POST error codes (continued)
Error
code
1783
Slot z Drive Array Controller Failure (might be
followed by an exclamation point, and one or
more of the following:)
[Board ID not programmed (replace ROMs or
replace controller)]
[I2C read error]
[Image checksum error]
[Inconsistent volume count]
[Inconsistent volume count (B)]
[Unexpected hardware revision]
[Incorrect EEPROM type]
[Init failure (cmd=##h, err=##h)]
[Command failure (cmd=##h, err=##h)]
[Self-test failure (ErrCode=####h)]
[I2C NVRAM reconfiguration failure]
[PCI bridge missing]
[PCI bridge disabled; check System ROM
version]
[Board ID not programmed]
1784
Slot z Drive Array Drive Failure The following disk
drive(s) should be replaced:
Port 1I: Box 1: Bay 3
1785
Slot z Drive Array not Configured (followed by
one of the following:)
No drives detected.
Array Accelerator Memory Size Increased - Run
System Configuration Utility.
SAS Cable(s) Attached to Wrong SAS Port
Connector(s). Turn system power OFF and swap
SAS port connectors to prevent data loss.
Drive positions cannot be changed during
Capacity Expansion.
Drive positions appear to have changed. Run
Drive Array Advanced Diagnostics if previous
positions are unknown. Then turn system power
OFF and move drives to their original positions.
Configuration information indicates drive
positions beyond the capability of this
controller. This may be due to drive movement
from a controller that supports more drives than
the current controller. To avoid data loss turn
system power OFF and reattach drives to the
original controller.
Configuration information indicates drives were
configured on a controller with a newer
firmware version. To avoid data loss, reattach
drives to original controller or upgrade
controller firmware.
Description
Level
Critical
Contact your HP support representative
for assistance.
Informational
Replace the indicated disk.
Informational or
Follow the instructions in the error
Critical
message to correct the error condition.
Corrective action
POST error codes