---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------
Array Accelerator Board Present?.... yes
Cache Configuration Status.......... cache enabled
Cache Ratio......................... 50% Read / 50% Write
Total Cache Size (MB)............... 208
Battery Pack Count.................. 1
Battery Status (pack #1)............ ok
---- LOGICAL DRIVE SUMMARY ---------------------------------------------------
#
RAID
0
ADG
---- SAS/SATA DEVICE SUMMARY -------------------------------------------------
Location
Ct Enc Bay
internal
1I
1
internal
1I
1
internal
1I
1
internal
1I
1
internal
2I
1
internal
2I
1
internal
2I
1
internal
2I
1
---- SAS/SATA ENCLOSURE SUMMARY ----------------------------------------------
Location
Ct
Enc
internal
1I
1
internal
2I
1
---- SAS/SATA DEVICE 1I:1:12:0x500000e01117c732 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 12
WWID............................................. 0x500000e01117c732
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55001SF0519
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 1I:1:11:0x500000e01115c352 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 11
WWID............................................. 0x500000e01115c352
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55001H70519
Device Firmware Version.......................... HPD4
Size
Status
15360 MB
OK
WWID
12
0x500000e01117c732
11
0x500000e01115c352
10
0x5000c5000032b839
9
0x5000c5000030b0c5
16
0x500000e011213482
15
0x5000c500002084c9
14
0x5000c5000030b9c9
13
0x500000e01118a7a2
Expander_count
0
0
Type
Capacity Status
DISK
36.4 GB
DISK
36.4 GB
DISK
36.4 GB
DISK
36.4 GB
DISK
36.4 GB
DISK
73.4 GB
DISK
36.4 GB
DISK
36.4 GB
Bay_count
SEP_count
4
1
4
1
Confirming and updating physical disk firmware
OK
OK
OK
OK
OK
OK