HP Smart Array -UX 11i v2 Support Manual page 10

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

Table 3 Interpreting Smart Array 41 1 runtime LEDs
LED ID
Color
1
Amber
2
Green
3
Green
4
Green
5
Green
6
Green
7
Green
8
Amber
9
Amber
Table 4 Determining Smart Array P41 1 controller CPU activity level
DS7 (Gas Pedal) Status
Off
Flashing
On steadily
On steadily
NOTE:
During server power on, each runtime LED illuminates randomly until POST completes.
10
Controller overview
Name
LED name and interpretation
DS9
System Error LED. The controller ASIC has locked up and cannot process
any commands.
DS8
Idle Task LED. This LED, with item 3 (DS7), indicates the amount of controller
CPU activity. See
DS7
Gas Pedal LED. This LED, with item 2 (DS8), indicates the amount of
controller CPU activity. See
DS6
Controller Heartbeat LED. This LED flashes every two seconds to indicate
controller health.
DS5
Pending Command LED. Indicates that the controller is working on a
command from the host driver.
DS4
Activity LED for SAS port 1.
DS3
Activity LED for SAS port 2.
DS2
Disk Failure LED. A physical disk connected to the controller has failed. See
the Fault LED on each disk to determine the failed disk.
DS1
Diagnostics Error LED. One of the server diagnostics utilities has detected
a controller error.
DS8 (Idle Task) Status
Flashing
Off
Off
On steadily
Table
6.
Table
4.
Controller CPU activity level
0 to 25%
25 to 50%
50% to 75%
75% to 100%

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart array hp-ux 11i v3

Table of Contents