Figure 14 Smart Array battery pack LEDs
Table 1 1 Battery pack LEDs
LED
Color
1
Green
2
Green
3
Amber
4
Green
Table 12 Interpreting battery pack LEDs
LED 3 State
--
--
--
--
--
18
Controller overview
Description
System Power LED. This LED glows steadily when the system is powered on and 12 V
system power is available. This power supply is used to maintain the battery charge
and provide supplementary power to the cache microcontroller.
Auxiliary Power LED. This LED glows steadily when 3.3 V auxiliary voltage is detected.
The auxiliary voltage is used to preserve BBWC data and is available when system
power cords are connected to a power supply.
Battery Health LED. See
BBWC Status LED. See
LED 4 State
Interpretation
One flash every
The system is powered off and the cache contains data that has not yet been
two seconds
written to the drives. Restore system power as soon as possible to prevent data
loss.
Data preservation time is extended when 3.3 V auxiliary power is available, as
indicated by LED 2. In the absence of auxiliary power, battery power preserves
the data. A fully-charged battery can normally preserve data for two days.
The battery lifetime also depends on the cache module size. For more information,
see the controller QuickSpecs on the HP website at:
http://www.hp.com
Flash twice, then
The cache microcontroller is waiting for the host controller to communicate.
pause
One flash per
The battery pack is below the minimum charge level and is being charged.
second
Features that require a battery (such as write cache, capacity expansion, stripe
size migration, and RAID migration) are unavailable until charging is complete.
The recharge process takes between 15 minutes and 2 hours, depending on the
initial capacity of the battery.
Steady glow
The battery pack is fully charged, and posted write data is stored in the cache.
Off
The battery pack is fully charged, and there is no posted write data in the cache.