HP Smart Array -UX 11i v2 Support Manual page 69

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 2E:1:1:0x5000c50005962f7d [DISK] ------------------------
Connector Location............................... external
Connector........................................ 2E
Enclosure........................................ 1
Bay.............................................. 1
WWID............................................. 0x5000c50005962f7d
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0LTCN000098047WWK
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
S.M.A.R.T. enabled............................. yes
S.M.A.R.T. errors (in powerup M&P data)........ no
Attached to external connector................. yes
Configured in a logical drive.................. yes
Configured as a spare disk..................... no
Disk write cache enabled at spin up............ no
Supports redundant controller operation........ no
Disk write cache enabled in current page....... no
Disk write cache disabled in default page...... yes
---- SAS/SATA DEVICE 2E:1:2:0x5000c50005962a09 [DISK] ------------------------
Connector Location............................... external
Connector........................................ 2E
Enclosure........................................ 1
Bay.............................................. 2
WWID............................................. 0x5000c50005962a09
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DH072ABAA6
Device Serial Number............................. 3PD0KY2A00009802DRNR
Device Firmware Version.......................... HPD2
Reserved Area (cfg/status info).................. 33554.4 KB (33.6 MB)
Block Size (bytes/sector)........................ 512 bytes
M&P Data Stamped?................................ yes
Last Failure Reason.............................. none
Physical Disk Flags:
Disk present and operational................... yes
Non-disk device detected....................... no
S.M.A.R.T. supported........................... yes
S.M.A.R.T. errors (in factory M&P data)........ no
The sautil command