Table 20 Smart Array controller POST error codes (continued)
Error
code
1786
Slot z Drive Array Recovery Needed.
The following disk drive(s) need Automatic Data
Recovery (Rebuild):
Port 1I: Box 2: Bay 5
Select "F1" to continue with recovery of data to
drive(s).
Select "F2" to continue without recovery of data
to drive(s).
OR
Slot 1 Drive Array Recovery Needed
The following disk drive(s) need Automatic Data
Recovery (Rebuild):
Port 2I: Box 1: Bay 4
Automatic Data Recovery previously Aborted!
Select "F1" to retry Automatic Data Recovery.
Select "F2" to continue without starting Automatic
Data Recovery.
1787
Slot z Drive Array Operating in Interim Recovery
Mode. The following disk drive(s) should be
replaced:
Port 1I: Box 3: Bay 1
1788
Slot z Drive Array Reports Incorrect Drive
Replacement. The following disk drive(s) should
have been replaced:
Port 1I: Box 2: Bay 1
The following SCSI drive(s) were incorrectly
replaced:
Port 2I: Box 1: Bay 3
1789
Slot z Drive Array Physical Drive(s) Not
Responding. Check cables or replace the following
physical drive(s):
Port 1I: Box 1: Bay 8
1792
Slot z Drive Array - Valid Data Found in Array
Accelerator. Data will automatically be written to
drive array.
1793
Slot z Drive Array – Data in Array Accelerator has
been Lost
Array Accelerator Battery Depleted
(Error message 1794 will also be displayed.)
1794
Slot z Drive Array - Array Accelerator Battery
Charge Low.
Array Accelerator Posted-Write Cache is
temporarily disabled. Array Accelerator will be
reenabled when battery reaches full charge
(or: Array Accelerator batteries have failed and
should be replaced)
1 14
Power-on Self Test (POST) error codes
Description
Level
Informational
Follow the instructions in the error
message to correct the error condition.
Informational
Replace the indicated disk.
Informational
Press F1 to continue. The drive array
remains disabled.
Press F2 to reset configuration - all
data will be lost.
Warning: Pressing F2 erases all data
in the array. Be sure you have a valid,
current backup of the affected logical
drives before selecting this option.
Informational
Press F1 to continue. The drive array
remains disabled.
Press F2 to fail drives that are not
responding. Interim Recovery Mode is
enabled if configured for fault
tolerance.
None
None.
Critical
The cache battery was depleted before
the system was returned to a state
where the cached data could be
written to the array. Data loss may
occur.
Informational if
Replace the cache battery, if
battery bad;
necessary.
otherwise None
Corrective action