7.2.7 Ambient Conditions, Ventilation and Mounting Position
Storage, hints
Transport, hints
Mains power supply
Aux. power supply
without brake and fan
with brake or fan
Surrounding air tem-
perature in operation
Humidity in operation
Site altitude
Pollution level
Vibrations
Enclosure protection
Mounting position
Ventilation
S303 und S341
all other types
7.2.8 Conductor cross-sections
Recommendations for cables (material and construction (➜ # 52)):
Interface
ACconnection
DDC bus link
Brake resistor
Motor cables up to 25m,
motor choke
Motor cables 25m to 50 m,
motor choke 3YL/3YLN
Resolver, motor thermal control
Encoder, motor thermal control
ComCoder, motor thermal control 8x2x0.25 mm², max. 25m twisted pairs, shielded
Setpoints, AGND
Control signals, BTB, DGND
Holding brake (motor)
+24 V / DGND
* Kollmorgen North America supplies cables up to 39 meters, Europe up to max. length
S300 Instructions Manual | 7 Technical description
(➜ # 16)
(➜ # 16)
S303-S310:
1x110V-10% ...1x230V+10%, 50/60 Hz
3x110V-10% ...3x230V+10%, 50/60 Hz
S341-S346:
3x208V-10% ...3x 480V+10%, 50/60 Hz
20 V DC ... 30 V DC
24 V DC (-0% +15%),check voltage drop
0 to +40°C (32 to 104°F) at rated data
+40 to +55°C (113 to 131°F) with power derating 2.5% / K
rel. humidity 85%, no condensation, class 3K3
up to 1000m a.m.s.l. without restriction
1000 — 2500m a.m.s.l. with power derating 1.5%/100m
Pollution level 2 to EN 60664-1
Class 3M2 according to IEC 60721-3-3
IP 20 according to EN60529
generally vertical (➜ # 46)
natural convection
built-on fan (optionally controlled, Option FN (➜ # 134))
Make sure that there is sufficient forced ventilation within
the switchgear cabinet.
Cross section
1.5 mm²
2.5 mm²
1..1.5 mm², max. 25 m
1 mm², 25 - 50m*
4x2x0.25 mm²,
max.100m*
7x2x0.25 mm², max. 50m* twisted pairs, shielded
0.25 mm², max. 30m
0.5 mm², max. 30m
min. 0.75 mm²
max. 2.5 mm²
For multi-axis systems, observe the specific operating
conditions for your system. To reach the max. permitted
cable length, observe cable requirements (➜ # 52).
Kollmorgen | kdn.kollmorgen.com | May 2020
Techn. Requirements
600V,80°C
1000V, 80°C,
shielded for lengths >0.20m
600V,80°C, shielded,
capacitance <150pF/m
600V,80°C,shielded,
capacitance<150pF/m
twisted pairs, shielded,
capacitance<120pF/m
twisted pairs, shielded
600V, 80°C, shielded,
check voltage drop
check voltage drop