Product Life Cycle Handling; Transport; Packaging; Storage - Kollmorgen SERVOSTAR 300 Instruction Manual

Digital servo amplifier
Hide thumbs Also See for SERVOSTAR 300:
Table of Contents

Advertisement

S300 Instructions Manual | 4   Product life cycle handling

4 Product life cycle handling

4.1 Transport

Transport the SERVOSTAR 300 in accordance with IEC 61800-2 as follows:
The servo amplifiers contain electrostatically sensitive components which can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid contact
with highly insulating materials (artificial fabrics, plastic films etc.). Place the servo amplifier
on a conductive surface.

4.2 Packaging

The S300 packaging consists of recyclable cardboard with inserts.

4.3 Storage

Store the S300 in accordance with IEC 61800-2 as follows:

4.4 Installation, setup and normal operation

In normal operation, the cabinet door must be closed and the device must not be touched.
Installation and setup information are given in
Normal operation tested for environmental class 3K3 according to IEC 61800-2 (➜ # 29).
The manufacturer of the machine defines the necessary end user expertise based on the risk
assessment for the machine and describes the requirements for normal operation based on
the application.
16
Kollmorgen | kdn.kollmorgen.com | May 2020
Only by qualified personnel in the manufacturer's original recyclable packaging
Avoid shocks
Temperature: –25 to +70°C, max. 20K/hr rate of change,
class 2K3 acc. to EN61800-2, EN 60721-3-1
Humidity: max. 95% relative humidity, no condensation,
class 2K3 acc. to EN61800-2, EN 60721-3-1
If the packaging is damaged, check the unit for visible damage. In this case, inform the
shipper and the manufacturer.
Dimensions (HxWxD): 115x365x275mm
Labeling : nameplate outside at the box
Storage only in the manufacturer's original recyclable packaging
Max. stacking height 8 cartons
Storage temperature: -25 to +55°C, max. rate of change 20°C / hour
class 1K4 acc. to EN61800-2, EN 60721-3-1
Storage humidity: 5 ... 95% relative humidity, no condensation
class 1K3 acc. to EN61800-2, EN 60721-3-1
Storage duration: Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC
for about 30 minutes to the terminals L1 / L2.