5.2.2 Functional Safety Conformance (STO) according to EC Machinery Directive
The S300 servo amplifier offers a single channel STO function (Safe Torque Off) that can be
used as a functional safe restart lock.
The safetys concept is certified. The safety circuit concept for realizing the safety function
"Safe Torque Off" in the servo amplifiers S300 is suited for SIL CL 2 according to IEC 62061
and PLd according to ISO 13849-1.
The subsystems (servo amplifiers) are totally described for safety technics with the char-
acteristic data SIL CL, PFHD and TM.
Device
STO-Enable
5.2.3 Conformance with RoHS
The device is manufactured in conformance with RoHS Directive 2011/65/EU with delegated
directive 2015/863/EU for installation into a machine.
5.2.4 Conformance with REACH
EU Regulation no. 1907/2006 deals with the registration, evaluation, authorization and restric-
tion of chemical substances 1 (abbreviated to "REACH").
The device does not contain any substances (CMR substances, PBTsubstances, vPvB sub-
stances and similar hazardous substances stipulated in individual cases based on scientific
criteria) above 0.1 mass percent per product that are included on the candidate list.
5.3 Conformance with EAC
EAC is the abbreviation for Eurasian Conformity. The mark is used in the states of the Eur-
asian Customs Union (Russia, Belarus, Kazakhstan) similar to the European CE mark.
Kollmorgen declares, that the device has passed all required conformity procedures in a mem-
ber state of the Eurasian Customs Union, and that the device meets all technical require-
ments requested in the member states of the Eurasian Customs Union:
Low voltage (TP TC 020/2011)
Electromagnetic Compatibility (TP TC 004/2011)
Contact: SERVOSTAR LLC. , Bld.1, Semyonovskaya nab. 2/1, RU-105094 Moskau
Operation mode
EN 13849-1
single channel
PLd
Kollmorgen | kdn.kollmorgen.com | May 2020
S300 Instructions Manual | 5 Approvals
EN 62061
PFHD [1/h]
SIL CL 2
1.50E-07
TM [Year]
20