a. Click Resources.
b. On multi-site systems, select a site from the Sites pull-down menu.
c. In the Racks pull-down menu, select a system.
d. In the rack graphic, select the node you want to shut down. Typically, the node you want to shut
down has a failure icon overlay.
e. In the node's Actions pull-down menu, select Shutdown Node.
f. A pop-up appears asking you to confirm that all other nodes in the system are healthy. If so, type
the password for

Figure 3-40. Admin Password.

g. Wait for UniverStor SM to display a notification in a green banner indicating that the node was
shut down successfully:

Figure 3-41. Node successfully shut down banner

h. Confirm that you shut down the right node by checking that its front and back LEDs are off.
2. Disconnect all of the cables from the faulty Storage Node.
Important: Remove the drives before removing the Storage Node from the rack.
You do NOT have to decommission the drives.
3. Remove the 2.5 inch drives from the Storage Node. For more information, refer to
inch drive
on page 51.
4. Remove the 3.5 inch drives from the Storage Node. For more information, refer to
inch drive
on page 48.
5. Unscrew the thumb screws located on the front of the System Node.