Replaceable Parts For System Nodes - Western Digital ActiveScale P100 Support Manual

Table of Contents

Advertisement

ActiveScale™ P100 Support Guide
Table 2-3. System Node control panel LED and button descriptions (continued)
Number
Name
3
Fault
Identification
4
HDD activity
5
LAN1/LAN2
6
Power button
7
Reset button
8

2.1.2 Replaceable parts for System Nodes

The following table lists all of the replaceable components for a System Node.
Replaceable part
1 TB HDD with drive carrier
480 GB SSD with drive carrier
960 GB SSD with drive carrier
PSU module, 400 W
System Node chassis
1.Only hot swappable after decommissioning.
Description
Identifies system events.
Locater LED.
Identifies hard disk drive
access.
Identifies Link or LAN1/
LAN2 access
Powers on/off System Node. • Solid blue—Powered on
Resets the System Node.
Hot
swappable?
1
Yes
1
Yes
1
Yes
Yes
No
19
LED action
• Solid amber—Indicates the following events:
– Critical failure—critical fan, voltage,
temperature state.
– Non-critical failure—non-critical fan, voltage,
temperature state, CPU thermal trip, DC off.
• Blinking amber—Indicates a change or event has
occurred on the System Node. Use the SEL to get
more info and to clear it if appropriate.
• Off—SEL cleared or last pending warning or error
has been de-asserted.
• Solid blue—Identification feature has been
activated.
• Blinking—Identification LED has been activated
• Off—No identification request
• Blinking blue—Hard disk drive access (on-board
SATA port only)
• Off—No access (non-SAS)
• Solid blue—Link
• Blinking blue—LAN access (off when there is
traffic)
• Off—Powered off
N/A
Part number
1EX0222
1EX0221
1EX0258
1EX0209
1EX02231EX0207