Installing A 2.5 Inch Drive; Replacing Storage Node Psus; Removing A Storage Node Psu; Installing A Storage Node Psu - Western Digital ActiveScale P100 Support Manual

Table of Contents

Advertisement

ActiveScale™ P100 Support Guide
support.
If the status is Decommissioned, proceed with physical drive replacement.
e. Click the Ident button
f. Identify the physical location of the drive.
2. Press the drive carrier handle release. The handle will pop out.

Figure 3-37. Removing the 2.5 inch drive

3. Use the handle to pull the faulty SSD from the system.
4. Record the serial number of the faulty device for return purposes.

3.3.2.2 Installing a 2.5 inch drive

To install a replacement 2.5 inch drive:
1. Align the replacement drive with the empty slot and slide it into the Storage Node until it stops.
2. Press the drive carrier handle in until there is an audible click.
3. Check to make sure that the drive has been reintegrated and the status is Online. If the status is
Degraded, Decommissioning, or Decommissioned, wait for approximately 15 minutes and check
again.
Important: If the status does not change to Online, retry the replacement
process or contact Western Digital Corporation Support.

3.3.3 Replacing Storage Node PSUs

Table 3-18. Storage Node PSU replacement overview

Required tools
None

3.3.3.1 Removing a Storage Node PSU

To remove the Storage Node PSU:
1. Unplug the AC power cord from the faulty PSU.
2. Press the release lever in towards the handle to release the PSU.
3. Grasp the handle and pull with even pressure until the unit is removed.

3.3.3.2 Installing a Storage Node PSU

To install a replacement Storage Node PSU:
1. With the handle facing inward, align the replacement PSU with the empty slot.
2. Release the lever outward and push the PSU into the server until there is an audible click.
to light the front identification LED on the drive.
Personnel required
1
52
Replacement time
15 to 25 minutes

Advertisement

Table of Contents
loading