www.raisecom.com
iTN2100 (P100R002)
Hardware Description
(Rel_01)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iTN2100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Raisecom iTN2100

  • Page 1 (P100R002) Hardware Description (Rel_01)
  • Page 2 Raisecom Technology Co., Ltd. provides customers with comprehensive technical support and services. For any assistance, please contact our local offices or company headquarters. Website: http://www.raisecom.com Tel: 8610-82883305 Fax: 8610-82883056 Email: export@raisecom.com Address: Building 2, No. 28, Shangdi 6th Street, Haidian District, Beijing, P.R.China...
  • Page 3 This manual describes the integrated equipment, components, and cables of the iTN2100, including hardware features, components, functions of each component, cables, and specifications of these cables. To have a quick grasp of the iTN2100, please read this manual carefully. Versions The following table lists the product versions related to this document.
  • Page 4 Raisecom iTN2100 (P100R002) Hardware Description Preface Symbol Description Indicates a tip that may help you solve a problem or save time. General conventions Convention Description Times New Roman Normal paragraphs are in Times New Roman. Arial Paragraphs in Warning, Caution, Notes, and Tip are in Arial.
  • Page 5: Table Of Contents

    Raisecom iTN2100 (P100R002) Hardware Description Contents Contents 1 Overview ............................1 1.1 Introduction ..............................1 1.2 Components..............................1 2 Chassis ............................. 5 2.1 Structure ................................5 2.2 Slots .................................. 7 2.3 VC4 and GE distribution ..........................7 2.4 Specifications ..............................8 3 Fan ..............................
  • Page 6 Raisecom iTN2100 (P100R002) Hardware Description Contents 5.1 iTN2100-NMS ............................... 24 5.1.1 Appearance and functions ........................24 5.1.2 Slots ..............................24 5.1.3 Interfaces ............................... 25 5.1.4 Buttons ..............................26 5.1.5 LEDs ..............................26 5.1.6 Alarms ..............................27 5.1.7 Specifications ............................27 6 SDH aggregation card ........................
  • Page 7 Raisecom iTN2100 (P100R002) Hardware Description Contents 9.1 iTN2100-PTU-4GE ............................50 9.1.1 Appearance and functions ........................50 9.1.2 Slots ..............................50 9.1.3 Interfaces ............................... 51 9.1.4 LEDs ..............................51 9.1.5 Specifications ............................52 10 Ethernet access cards ........................ 53 10.1 iTN2100-16GF ............................. 54 10.1.1 Appearance and functions ........................
  • Page 8 Raisecom iTN2100 (P100R002) Hardware Description Contents 11.1.2 Slots ..............................73 11.1.3 Interfaces ............................. 74 11.1.4 LEDs ..............................75 11.1.5 Specifications ............................76 12 TDMoP card ..........................77 12.1 iTN2100-CES-16E1T1-BL .......................... 78 12.1.1 Appearance and functions ........................78 12.1.2 Slots ..............................78 12.1.3 Interfaces .............................
  • Page 9 Raisecom iTN2100 (P100R002) Hardware Description Contents 13.5.2 Slots ..............................97 13.5.3 Interfaces ............................. 98 13.5.4 LEDs ..............................98 13.5.5 Alarms ..............................99 13.5.6 Specifications ............................99 13.6 OPCOM3500E-EOP-FXE1× 8 ........................100 13.6.1 Appearance and functions ......................... 100 13.6.2 Slots ..............................100 13.6.3 Interfaces ............................
  • Page 10 Raisecom iTN2100 (P100R002) Hardware Description Contents 14.1.5 Alarms ............................... 119 14.1.6 Specifications ............................ 119 14.2 OPCOM3500E-EOS-8FE .......................... 120 14.2.1 Appearance and functions ......................... 120 14.2.2 Slots ..............................120 14.2.3 Interfaces ............................121 14.2.4 LEDs ..............................121 14.2.5 Specifications ............................ 122 14.3 OPCOM3500E-4EOS-4FX ........................
  • Page 11 Raisecom iTN2100 (P100R002) Hardware Description Contents 15.2 OPCOM3500E-32E1/32E1-BL........................140 15.2.1 Appearance and functions ......................... 140 15.2.2 Slots ..............................140 15.2.3 Interfaces ............................141 15.2.4 LEDs ..............................141 15.2.5 DIP switches ............................. 142 15.2.6 Alarms ............................... 142 15.2.7 Cables ..............................143 15.2.8 Specifications ............................
  • Page 12 Raisecom iTN2100 (P100R002) Hardware Description Contents 15.7.5 DIP switches ............................. 165 15.7.6 Alarms ............................... 168 15.7.7 Specifications ............................ 168 15.8 OPCOM3500E-120FE× 8L-GE ........................169 15.8.1 Appearance and functions ......................... 169 15.8.2 Slots ..............................169 15.8.3 Interfaces ............................170 15.8.4 LEDs ..............................171 15.8.5 Alarms ...............................
  • Page 13 Raisecom iTN2100 (P100R002) Hardware Description Contents 16 V.24 card ..........................16-192 16.1 OPCOM3500E-8V24 ..........................16-193 16.1.1 Appearance and functions ......................16-193 16.1.2 Slots ............................. 16-194 16.1.3 Interfaces ............................16-194 16.1.4 LEDs ............................16-194 16.1.5 Cables ............................16-195 16.1.6 Specifications ..........................16-195 17 V.35 card ............................
  • Page 14 Raisecom iTN2100 (P100R002) Hardware Description Contents 20.1 iTN2100-Gb ............................... 221 20.1.1 Appearance and functions ......................... 221 20.1.2 Slots ..............................221 20.1.3 Interfaces ............................222 20.1.4 LEDs ..............................225 20.1.5 DIP switches ............................. 226 20.1.6 Specifications ............................ 230 20.1.7 Ordering information ........................230 20.2 iTN2100-8SU-S ............................
  • Page 15 Raisecom iTN2100 (P100R002) Hardware Description Contents 21.4.3 Specifications ............................ 251 21.5 AC power cables ............................251 21.5.1 Introduction ............................251 21.5.2 Appearance ............................252 21.5.3 Technical specifications ........................252 21.6 Grounding cables ............................253 21.6.1 Introduction ............................253 21.6.2 Appearance ............................253 21.6.3 Specifications ............................
  • Page 16 Raisecom iTN2100 (P100R002) Hardware Description Contents 21.13.2 CBL-MUL-HDB26M/NC ....................... 272 21.13.3 CBL-MUL-HDB26M(40)/NC ......................274 22 Appendix ..........................277 22.1 Power consumption of optical/electrical modules ..................277 22.1.1 SFP modules ............................. 277 22.1.2 XFP modules ............................. 277 22.2 Terms ................................278 22.3 Abbreviations .............................
  • Page 17 Figure 3-2 Rear panel of the iTN2100 ......................... 10 Figure 19-1 Interface pins of the OPCOM3500E-12MT ................... 207 Figure 20-1 Point-to-point networking application with the iTN2100-8SU-S ........... 237 Figure 20-2 OADM ring network with the iTN2100-8SU-S ................238 Figure 20-3 Point-to-point networking application with the iTN2100-4SU-D ..........242 Figure 20-4 OADM ring network with the iTN2100-4SU-D ................
  • Page 18 Raisecom iTN2100 (P100R002) Hardware Description Figures Figure 21-17 CBL-E1-DB37F/16BNCM cable ....................258 Figure 21-18 CBL-E1-DB37F/8RJ45 cable ....................... 259 Figure 21-19 CBL-E1-SCSI100M(40)/32BNCF cable ..................260 Figure 21-20 CBL-E1-SCSI100M(40)/32BNCM cable ..................261 Figure 21-21 CBL-E1-SCSI100M(40)/16RJ45 cable ..................262 Figure 21-22 CBL-V24-HDB26M/4DB25F cable ..................... 263 Figure 21-23 CBL-V24-HDB26M/4DB25M cable ...................
  • Page 19 (P100R002) Hardware Description Tables Tables Table 1-1 All cards on the iTN2100 and their corresponding BUS ................ 2 Table 2-1 Descriptions of the chassis ........................6 Table 2-2 VC4 and GE distribution ........................7 Table 2-3 Specifications of the iTN2100........................ 8 Table 3-1 LEDs on the front panel of the FANS360 ....................
  • Page 20 Table 10-1 Interfaces on the iTN2100-16GF panel ....................55 Table 10-2 Parameters of interfaces 1–16 of the iTN2100-16GF ................ 55 Table 10-3 Properties of the TSFP module of the iTN2100-16GF ............... 55 Table 10-4 LEDs on the iTN2100-16GF panel ....................56 Table 10-5 Specifications of the iTN2100-16GF ....................
  • Page 21 Table 10-10 Specifications of the iTN2100-8FX ....................61 Table 10-11 Interfaces on the iTN2100-2IGC panel .................... 63 Table 10-12 Parameters of GE1 and GE2 electrical interfaces on the iTN2100-2IGC ........63 Table 10-13 Parameters of GE1 and GE2 optical interfaces on the iTN2100-2IGC ..........63 Table 10-14 LEDs on the iTN2100-2IGC panel ....................
  • Page 22 Raisecom iTN2100 (P100R002) Hardware Description Tables Table 13-6 Interfaces on the OPCOM3500E-EOP3FE panel ................87 Table 13-7 Parameters of the RJ45 interface on the OPCOM3500E-EOP3FE ............ 87 Table 13-8 Parameters of interfaces 1–2 on the OPCOM3500E-EOP3FE............87 Table 13-9 LEDs on the OPCOM3500E-EOP3FE panel ..................88 Table 13-10 Alarms generated on the OPCOM3500E-EOP3FE ................
  • Page 23 Table 13-43 Parameters of interfaces 1–4 on the iTN2100-EOT-GESTM4 ............112 Table 13-44 LEDs on the iTN2100-EOT-GESTM4 panel ................. 112 Table 13-45 Configurations of the DIP switch on the iTN2100-EOT-GESTM4 ..........113 Table 13-46 Alarms of the iTN2100-EOT-GESTM4 ..................114 Table 13-47 Specifications of the iTN2100-EOT-GESTM4 ................
  • Page 24 Raisecom iTN2100 (P100R002) Hardware Description Tables Table 14-25 Parameters of the 1× 9 optical interface on the OPCOM3500E-8EOS-FX ........132 Table 14-26 LEDs on the OPCOM3500E-8EOS-FX panel ................132 Table 14-27 Configurations of DIP switch SW2 on the OPCOM3500E-8EOS-FX .......... 133 Table 14-28 Configurations of DIP switch SW3 on the OPCOM3500E-8EOS-FX ..........
  • Page 25 Raisecom iTN2100 (P100R002) Hardware Description Tables Table 15-28 Specifications of the OPCOM3500E-120EOS× 4 ................159 Table 15-29 Interfaces on the OPCOM3500E-120EOS× 4L ................161 Table 15-30 Parameters of interfaces 1–4 on the OPCOM3500E-120EOS× 4L ..........161 Table 15-31 LEDs on the OPCOM3500E-120EOS× 4L panel ................161 Table 15-32 Specifications of the OPCOM3500E-120EOS×...
  • Page 26 Raisecom iTN2100 (P100R002) Hardware Description Tables Table 15-61 Interfaces on the OPCOM3500E-240H× 2 panel ................183 Table 15-62 LEDs on the OPCOM3500E-240H× 2 .................... 183 Table 15-63 Configurations of DIP switch SW2 on the OPCOM3500E-240H× 2 ..........184 Table 15-64 Configurations of DIP switch SW3 on the OPCOM3500E-240H× 2 ..........184 Table 15-65 Alarm of the OPCOM3500E-240H×...
  • Page 27 Table 20-5 LEDs on the iTN2100-Gb panel ...................... 225 Table 20-6 BITs 1–8 of the DIP switch ......................227 Table 20-7 Configurations on client-side interfaces of the iTN2100-Gb (A) ............. 228 Table 20-8 Configurations on client-side interfaces of the iTN2100-Gb (B) ............. 229 Table 20-9 Specifications of the iTN2100-Gb ....................
  • Page 28 Table 21-10 Pins of the alarm terminal ......................254 Table 21-11 Specifications of the E1-CC3 cable ....................255 Table 21-12 Relations between the E1-DB37 cable and the card on the iTN2100 ..........255 Table 21-13 Technical specifications of the CBL-E1-DB37F(40)/16NC cable ..........256 Table 21-14 Definitions of pins on the CBL-E1-DB37F(40)/16NC cable ............
  • Page 29 Table 21-32 PIN of the HDB26 interface on the OPCOM3500E-8V35 ............269 Table 21-33 PIN of the HDB26 interface on the OPCOM3500E-4V35 ............270 Table 21-34 Relationships between the MUL-HDB26 cable and the card on the iTN2100....... 271 Table 21-35 Specifications of the CBL-MUL-HDB26M/NC cable ..............272 Table 21-36 Color modes of the CBL-MUL-HDB26M/NC cable ..............
  • Page 30: Overview

     Components 1.1 Introduction The iTN2100, developed by Raisecom, is an integrated service access device targeted at the network access layer. The iTN2100, features with dual-network and dual-core structure, is compatible with both SDH and Packet Switched (PS), thus implementing integrated access and comprehensive management.
  • Page 31: Table 1-1 All Cards On The Itn2100 And Their Corresponding Bus

    It also supports -48 V or 110 V DC power input and 110 V or 220 V DC power input. Dust-proof mesh The bottom of the iTN2100 can be installed with a dust-proof mesh to prevent dusts in air from accessing the iTN2100 through the airflow of the fan. This helps avoid influencing the device performances.
  • Page 32 Raisecom iTN2100 (P100R002) Hardware Description Overview Card Type OPCOM3500E-EOP8FX OPCOM3500E-EOP-FE16E1 OPCOM3500E-EOP-FEE1× 8 OPCOM3500E-EOP-FXE1× 8 OPCOM3500E-EOPS-8E1 OPCOM3500E-HT-6FE24E1 iTN2100-EOT-GESTM4 SDH BUS ETH BUS EOS card OPCOM3500E-EOS-8FE SDH BUS OPCOM3500E-4EOS-4FE OPCOM3500E-4EOS-4FX OPCOM3500E-8EOS-FE OPCOM3500E-8EOS-FX PDH and RCMS card OPCOM3500E-16E1 OPCOM3500E-16E1-BL OPCOM3500E-32E1 OPCOM3500E-32E1-BL OPCOM3500E-P240EOS OPCOM3500E-P240FE OPCOM3500E-120EOS×...
  • Page 33 Raisecom iTN2100 (P100R002) Hardware Description Overview Card Type OPCOM3500E-MULTI Service aggregation card iTN2100-Gb SDH BUS iTN2100-8SU-S iTN2100-4SU-D Raisecom Technology Co., Ltd.
  • Page 34: Chassis

    Specifications 2.1 Structure The iTN2100 has a 19-inch 6-U standard chassis, complying with the IEC297 standards. The dimensions are 480 mm (width) × 248 mm (depth) × 267 mm (height). Figure 2-1 and Figure 2-2 show the outlook of the chassis.
  • Page 35: Figure 2-2 Rear Panel Of The Chassis

    Raisecom iTN2100 (P100R002) Hardware Description Chassis Figure 2-2 Rear panel of the chassis Table 2-1 lists descriptions of the chassis. Table 2-1 Descriptions of the chassis Name Description Rack-mount bracket Used to fix the chassis to a bench Card slot Cards are plugged into slots 0–12.
  • Page 36: Slots

    Raisecom iTN2100 (P100R002) Hardware Description Chassis Name Description Chassis grounding terminal Used to ground by the chassis DC power interface DC power input 2.2 Slots Figure 2-3 shows relations between slots and cards. Figure 2-3 Relations between slots and cards The corresponding relations are as below: ...
  • Page 37: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description Chassis 2.4 Specifications Table 2-3 lists specifications of the iTN2100. Table 2-3 Specifications of the iTN2100 Parameter Value Dimensions 480 mm (width) × 248 mm (depth) × 267 mm (height) Weight < 7 kg Power Min.
  • Page 38: Fan

    (P100R002) Hardware Description 3 Fan This chapter describes the intelligent fan of the iTN2100, which is named FANS360. The FANS360 is 19 inch wide and 1 U high. It has four feet through which it is fixed on the upper part of the iTN2100.
  • Page 39: Leds

    (P100R002) Hardware Description 3 Fan Figure 3-1 Front panel of the FANS360 Figure 3-2 Rear panel of the iTN2100 3.3 LEDs Table 3-1 lists LEDs on the front panel of the FANS360. Table 3-1 LEDs on the front panel of the FANS360...
  • Page 40 Raisecom iTN2100 (P100R002) Hardware Description 3 Fan Parameter Value Power supply voltage 30 V–57 V Maximum current 0.5 A Maximum power 28 W Raisecom Technology Co., Ltd.
  • Page 41: Power Supplies

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies Power supplies This chapter describes power supplies supported by the iTN2100, including the following sections:  SUB-PWRII-DC/DC-300  SUB-PWRM-DC  SUB-PWRM-AC The iTN2100 supports duel-power supply backup. It supports dual-DC, dual-AC, or hybrid AC/DC power supplies.
  • Page 42: Sub-Pwrii-Dc/Dc-300

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies 4.1 SUB-PWRII-DC/DC-300 4.1.1 Appearance and functions Appearance Function The SUB-PWRII-DC and SUB-PWRII-DC-300 are unintelligent DC power supplies. The SUB-PWRII-DC has two types: -48 V/150 W and 110 V/300 W.  Provide power switch.
  • Page 43: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies 4.1.3 LEDs Table 4-1 lists LEDs on the SUB-PWRII-DC/DC-300 panel. Table 4-1 LEDs on the SUB-PWRII-DC/DC-300 panel Status Description 5V PWR Green +5 V power output LED  Green: +5 V power output is normal.
  • Page 44 Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies Card SUB-PWRII-DC SUB-PWRII-DC SUB-PWRII- Remark (110 V/300 W) DC-300 Parameter (-48 V/150 W) parameters – Output over voltage protection – Output current limit 33 A 72 A 72 A protection Raisecom Technology Co., Ltd.
  • Page 45: Sub-Pwrm-Dc

    Support single-level alarms of output overvoltage and output undervoltage.  Support realtime reporting of power environment temperature  Support 1+1 hot backup.  Support hot swapping. 4.2.2 Slots The SUB-PWRM-DC can be plugged into slots POWER1 and POWER2 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 46: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies 4.2.3 LEDs Table 4-3 lists LEDs on the SUB-PWRM-DC panel. Table 4-3 LEDs on the SUB-PWRM-DC panel Status Description 5V PWR Green +5 V power output LED  Green: +5 V power output is normal.
  • Page 47: Table 4-4 Specifications Of The Sub-Pwrm-Dc

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies Table 4-4 Specifications of the SUB-PWRM-DC Parameter Value Dimensions 38.5 mm (width) × 224 mm (depth) × 240 mm (height) Weight 1.05 kg Zero-load power consumption Rated power consumption 300 W Table 4-5 lists input parameters of the SUB-PWRM-DC.
  • Page 48: Sub-Pwrm-Ac

    Support alarms on power supply type, power failure, over high or over low input voltage.  Support over temperature protection.  Support hot swapping. 4.3.2 Slots The SUB-PWRM-AC can be plugged into slots POWER1 and POWER2 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 49: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies 4.3.3 Interfaces Table 4-7 lists interface on the SUB-PWRM-AC panel. Table 4-7 Interface on the SUB-PWRM-AC panel Print Description – AC interface 4.3.4 LEDs Table 4-8 lists LEDs on the SUB-PWRM-AC panel.
  • Page 50: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies Status Description Input voltage hierarchical alarm LED  Red: the deviation between the input voltage and the centered voltage is within range 3.  Off: the deviation between the input voltage and the centered voltage is beyond range 3.
  • Page 51: Table 4-11 Protection Function Parameters Of The Sub-Pwrm-Ac

    Raisecom iTN2100 (P100R002) Hardware Description 4 Power supplies Table 4-11 lists protection function parameters of the SUB-PWRM-AC. Table 4-11 Protection function parameters of the SUB-PWRM-AC Parameter Value Input overcurrent protection 15 A Input undervoltage protection 85 V Output overcurrent protection...
  • Page 52: Nms Card

    Raisecom iTN2100 (P100R002) Hardware Description 5 NMS card NMS card This chapter describes the NMS card on the iTN2100, including the following section:  iTN2100-NMS Raisecom Technology Co., Ltd.
  • Page 53: Itn2100-Nms

     Provide Virtual Channel Connection (VCC) channel through E1 signals. Through this function, you can manage a remote iTN2100 through the transportation network. The iTN2100 supports four VCC channels at most.  Support four DCC channels by each slot. Each DCC channel supports three modes: D1- D3, D4-D12, D1-D12.
  • Page 54: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 5 NMS card 5.1.3 Interfaces Interface types There are four interfaces on the iTN2100-NMS panel, as listed in Table 5-1. Table 5-1 Interfaces on the iTN2100-NMS panel Print Connector type Description SNMP RJ45 NMS interface...
  • Page 55: Buttons

    Raisecom iTN2100 (P100R002) Hardware Description 5 NMS card 5.1.4 Buttons There are two buttons on the iTN2100-NMS panel, as listed in Table 5-4. Table 5-4 Buttons on the iTN2100-NMS panel Button Name Status Description – Buzzer control MUTE In this status, when an alarm is being button generated, the buzzer is mute.
  • Page 56: Alarms

    Off: the NM-EXT interface is disconnected or is working improperly.  Blinking green: the NM-EXT interface is receiving or sending data. 5.1.6 Alarms Table 5-6 lists alarms of the iTN2100-NMS. Table 5-6 Alarms of the iTN2100-NMS Alarm Cause Level ...
  • Page 57: Sdh Aggregation Card

    Raisecom iTN2100 (P100R002) Hardware Description 6 SDH aggregation card SDH aggregation card This chapter describes the SDH aggregation card on the iTN2100, including the following section:  OPCOM3500E-2STM1/4-M Raisecom Technology Co., Ltd.
  • Page 58: Opcom3500E-2Stm1/4-M

    Support SDH line clock, external clock, and crystal oscillator as clock source of the iTN2100. These sources provide protection by priority or by clock quality. The card provides 2 Mbit/s or 2 MHz external clock interface, complying with the ITU-T G.813 recommendations.
  • Page 59: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 6 SDH aggregation card 6.1.3 Interfaces Interface types There are five interfaces on the OPCOM3500E-2STM1/4-M panel, as shown in Table 6-1. Table 6-1 Interfaces on the OPCOM3500E-2STM1/4-M panel Interface Type Description – MiniUSB Debugging interface ...
  • Page 60: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 6 SDH aggregation card Parameter Description Signal rate 2048 Kbit/s 75 Ω Interface impedance Electrical parameters Comply with ITU-T G.703 recommendations. Table 6-4 Parameters of the 2 MHz clock interface the OPCOM3500E-2STM1/4-M Parameter Description Connector...
  • Page 61: Dip Switch

    By default, Bit1 and Bit2 of SW3 are OFF.  If Bit1 and Bit2 of SW3 are not concurrently ON nor OFF and the optical interface rate is not configured, the iTN2100 still sets the rate to STM-1 by default. ...
  • Page 62: Table 6-7 Alarms Of The Opcom3500E-2Stm1/4-M

    Raisecom iTN2100 (P100R002) Hardware Description 6 SDH aggregation card Table 6-7 Alarms of the OPCOM3500E-2STM1/4-M Alarm Cause Level  Attenuation of received signals is over great. RS-LOS Critical  The peer sender fails.  The connector of fiber is dirty or improperly connected.
  • Page 63: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 6 SDH aggregation card 6.1.7 Specifications Table 6-8 lists specifications of the OPCOM3500E-2STM1/4-M. Table 6-8 Specifications of the OPCOM3500E-2STM1/4-M Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight < 0.5 kg Max.
  • Page 64: Sdh Tributary Cards

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards SDH tributary cards This chapter describes the SDH tributary cards of the iTN2100, including the following sections:  OPCOM3500E-STM1-S  OPCOM3500E-4STM1-S Raisecom Technology Co., Ltd.
  • Page 65: Opcom3500E-Stm1-S

    The left figure is the the OPCOM3500E-STM1-S panel (versions A and B) and the right figure is the OPCOM3500E-STM1-S panel (version C). 7.1.2 Slots The OPCOM3500E-STM1-S can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 66: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards 7.1.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-STM1-S panel, as listed in Table 7-1 and Table 7-2. Table 7-1 Interfaces on the OPCOM3500E-STM1-S (Versions A and B) Interface...
  • Page 67: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards Parameter Description Line code Multiplexing structure Comply with ITU-T G.707 recommendations. Jitter Comply with ITU-T G.783 and ITU-T G.825 recommendations. Optical interface parameters Comply with ITU-T G.957 recommendations. 7.1.4 LEDs There are eight LEDs on the OPCOM3500E-STM1-S (Versions A and B) panel, as listed in Table 7-5.
  • Page 68: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards Table 7-6 LEDs on the OPCOM3500E-STM1-S (Version C) panel Status Description Green Power LED  Green: the power supply is normal.  Off: the power supply is abnormal. Green System status LED ...
  • Page 69: Table 7-8 Specifications Of The Opcom3500E-Stm1-S

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards Table 7-8 Specifications of the OPCOM3500E-STM1-S Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight < 0.45 kg Max. power consumption Raisecom Technology Co., Ltd.
  • Page 70: Opcom3500E-4Stm1-S

    Support Digital Diagnostics Monitoring (DDM) of the SFP module.  Support ALS.  Support online software upgrade over local and remote devices.  Support hot swapping. 7.2.2 Slots The OPCOM3500E-4STM1-S can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 71: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards 7.2.3 Interfaces Interface types There are five interfaces on the OPCOM3500E-4STM1-S panel, as listed in Table 7-9. Table 7-9 Interfaces on the OPCOM3500E-4STM1-S panel Interface Type Description – MiniUSB Debugging interface ...
  • Page 72: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards Status Description Green System status LED  Green: the system is working improperly.  Off: the system is working improperly.  Blinking green: the system is working properly. LOF (1–4) LOF alarm LED ...
  • Page 73: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 7 SDH tributary cards Alarm Cause Level MS-AIS Multiplexing section alarm LED Minor  Alarm signals are inserted in the optical signals sent by the peer device.  The peer device is a regenerator and receives LOS, LOF, or OOF alarms.
  • Page 74: Ethernet Aggregation Card

    Raisecom iTN2100 (P100R002) Hardware Description 8 Ethernet aggregation card Ethernet aggregation card This chapter describes the Ethernet aggregation card of the iTN2100, including the following section:  iTN2100-NTU-4GF Raisecom Technology Co., Ltd.
  • Page 75: Itn2100-Ntu-4Gf

    8.1 iTN2100-NTU-4GF 8.1.1 Appearance and functions Appearance Function The iTN2100-NTU-4GF is a 1000 Mbit/s Ethernet aggregation card used by the iTN2100. It has complete Multi-Protocol Label Switching-Transport Profile (MPLS-TP) networking capability.  The iTN2100-NTU-4GF is mainly used for the Packet Transport Network (PTN). As the...
  • Page 76: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 8 Ethernet aggregation card 8.1.3 Interfaces Interface types There are seven interfaces on the iTN2100-NTU-4GF panel, as listed inTable 8-1. Table 8-1 Interfaces on the iTN2100-NTU-4GF panel Interface Type Description – MiniUSB Debugging interface 1–4...
  • Page 77: Specifications

     Blinking green: the SFP optical interface is receiving or sending data. 8.1.5 Specifications Table 8-4 lists specifications of the iTN2100-NTU-4GF. Table 8-4 Specifications of the iTN2100-NTU-4GF Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.52 kg...
  • Page 78: Ethernet Switching Card

    Raisecom iTN2100 (P100R002) Hardware Description 9 Ethernet switching card Ethernet switching card This chapter describes the Ethernet switching card on the iTN2100, including the following section:  iTN2100-PTU-4GE Raisecom Technology Co., Ltd.
  • Page 79: Itn2100-Ptu-4Ge

    Support DDM for the SFP module.  Support hot swapping. 9.1.2 Slots The iTN2100-PTU-4GE can be plugged into slots 9 and 10 on the iTN2100. If you use only one iTN2100-PTU-4GE, you must plug it into slot 9. Raisecom Technology Co., Ltd.
  • Page 80: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 9 Ethernet switching card 9.1.3 Interfaces Interface types There are seven interfaces on the iTN2100-PTU-4GE panel, as listed in Table 9-1. Table 9-1 Interfaces on the iTN2100-PTU-4GE panel Interface Type Description – MiniUSB Debugging interface ...
  • Page 81: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 9 Ethernet switching card Table 9-3 LEDs on the iTN2100-PTU-4GE panel Status Description Green Power LED  Green: the power supply is normal.  Off: the power supply is abnormal. Green System status LED ...
  • Page 82: Ethernet Access Cards

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards Ethernet access cards This chapter describes Ethernet access cards of the iTN2100, including the following sections:  iTN2100-16GF  iTN2100-8FX  iTN2100-2IGC  OPCOM3500E-4FX  OPCOM3500E-8FX Raisecom Technology Co., Ltd.
  • Page 83: Itn2100-16Gf

    10 Ethernet access cards 10.1 iTN2100-16GF 10.1.1 Appearance and functions Appearance Function The iTN2100-16GF is an Ethernet access card used by the iTN2100. It aggregates 16-way 1000 Mbit/s Ethernet services of the iTN2100.  Support up to 16-way GE services. ...
  • Page 84: Slots

    10 Ethernet access cards 10.1.2 Slots The iTN2100-16GF can be plugged into slots 1–5, slot 8, and slots 11–12 on the iTN2100. When one of slots 9–10 is inserted with a switching card, the other slot can be inserted with the iTN2100-16GF card.
  • Page 85: Leds

    (Km) TSFP-Gb/DS14-3 1490(DFB) -10 to -3 Raisecom TSFP is called as Compact SFP (CSFP) in the industry. To differ from Raisecom CWDM SFP (CSFP) and highlight the feature of 2 channels, Raisecom names all Compact SFP as TSFP. 10.1.4 LEDs There are 19 LEDs on the iTN2100-16GF panel, as listed in Table 10-4.
  • Page 86 Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards Parameter Value Weight 0.5 kg Max. power consumption 30 W Raisecom Technology Co., Ltd.
  • Page 87: Itn2100-8Fx

    10.2 iTN2100-8FX 10.2.1 Appearance and functions Appearance Function The iTN2100-8FX is an 8-way 100 Mbit/s Ethernet optical signal access card on the iTN2100.  Aggregate eight ways of Ethernet optical signals into one way of GE signals and then send them to the switching card through the backplane. Meanwhile, it sends clock signals sent from the switching card to the peer device (such as transceiver).
  • Page 88: Slots

    (P100R002) Hardware Description 10 Ethernet access cards 10.2.2 Slots The iTN2100-8FX can be plugged into slots 1–5 and 8–12 on the iTN2100. 10.2.3 Interface Interface type There are nine interfaces on the iTN2100-8FX panel, as listed in Table 10-6.
  • Page 89: Leds

    The transmission distance in Table 10-8 is the maximum transmission distance in typical fiber conditions. The actual transmission distance depends on the network. 10.2.4 LEDs There are 10 LEDs on the iTN2100-8FX panel, as listed in Table 10-9. Table 10-9 LEDs on the iTN2100-8FX panel Status...
  • Page 90: Table 10-10 Specifications Of The Itn2100-8Fx

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards Table 10-10 Specifications of the iTN2100-8FX Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.4 kg Max. power consumption 15 W Raisecom Technology Co., Ltd.
  • Page 91: Itn2100-2Igc

    10.3.1 Appearance and functions Appearance Function The iTN2100-2IGC is a 2-way 1000 Mbit/s Ethernet service access card, which must be used together with the iTN2100-PTU-4GE to implement switching.  Provide two groups of GE interfaces (Combo interface, an optical interface and an electrical interface in each group) for service access.
  • Page 92: Interface

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards 10.3.3 Interface Interface types There are five interfaces on the iTN2100-2IGC panel, as listed in Table 10-11. Table 10-11 Interfaces on the iTN2100-2IGC panel Interface Type Description – MiniUSB Debugging interface –...
  • Page 93: Leds

    Full duplex Maximum supported frame length 10 KBytes Compliance standard IEEE802.3u and IEEE802.3z 10.3.4 LEDs There are 10 LEDs on the iTN2100-2IGC panel, as listed in Table 10-14. Table 10-14 LEDs on the iTN2100-2IGC panel Status Description Green Power LED ...
  • Page 94: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards 10.3.5 Specifications Table 10-15 lists specifications of the iTN2100-2IGC. Table 10-15 Specifications of the iTN2100-2IGC Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.36 kg Max.
  • Page 95: Opcom3500E-4Fx

     Support transparently transmitting BPDU, LACP, and 802.1x management frames.  Support NMS for remote transceivers.  Support hot swapping. 10.4.2 Slots The OPCOM3500E-4FX can be plugged into slots 1–5, 8, and 10–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 96: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards 10.4.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-4FX panel, as listed in Table 10-16. Table 10-16 Interfaces on the OPCOM3500E-4FX panel Interface Type Description  Each interface transmits one way of Ethernet 1–4...
  • Page 97: Dip Swtiches

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards Status Description LNK/ACT Green Link working LED (1–4)  Green: the link interface is properly connected.  Off: the link interface improperly connected or disconnected.  Blinking green: the link interface is receiving or sending data.
  • Page 98: Opcom3500E-8Fx

    Support interface-based non-linear rate limiting ranging from 62 Kbit/s to 100 Mbit/s.  Support transparently transmitting BPDU, LACP, and 802.1x management frames.  Support NMS for remote transceivers.  Support hot swapping. 10.5.2 Slots The OPCOM3500E-8FX can be plugged into slots 1–5 and 10–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 99: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards 10.5.3 Interfaces Interface types There are eight interfaces on the OPCOM3500E-8FX panel, as listed in Table 10-21. Table 10-21 Interfaces on the OPCOM3500E-8FX panel. Interface Parameter Description 1–8 SFP optical interface Each interface transmits one way of Ethernet optical signals.
  • Page 100: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 10 Ethernet access cards Interface Status Description LNK/ACT Green Link working LED (1–8)  Green: the link interface is properly connected.  Off: the link interface improperly connected or disconnected.  Blinking green: the link interface is receiving or sending data.
  • Page 101: Clock Card

    Raisecom iTN2100 (P100R002) Hardware Description 11 Clock card Clock card This chapter describes the clock card of the iTN2100, including the following section:  iTN2100-TSU Raisecom Technology Co., Ltd.
  • Page 102: Itn2100-Tsu

    Support 2 MHz and 2 Mbit/s signal templates that meet the G.703 requirements. 11.1.2 Slots The iTN2100-TSU can be plugged into slots 1, 5 or 8 on the iTN2100. Only one iTN2100- TSU card is available for the iTN2100. Raisecom Technology Co., Ltd.
  • Page 103: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 11 Clock card 11.1.3 Interfaces Interface types There are six interfaces on the iTN2100-TSU panel, as listed in Table 11-1. Table 11-1 Interfaces on the iTN2100-TSU panel Interface Type Description  Supports two 2048 Kbit/s or 2048 KHz external...
  • Page 104: Leds

    TOD time information, cooperating with the 1PPS RS-232-RXD of the BNC interface 422_1_N 1PPS 422_1_P 1PPS 422_2_N TOD time information 422_2_P TOD time information 11.1.4 LEDs There are 4 LEDs on the iTN2100-TSU panel, as listed in Table 11-5. Raisecom Technology Co., Ltd.
  • Page 105: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 11 Clock card Table 11-5 LEDs on the iTN2100-TSU panel Status Description Green Power LED  Green: the power supply is normal.  Off: the power supply is abnormal. Green System status LED  Green: the system is working improperly.
  • Page 106: Tdmop Card

    Raisecom iTN2100 (P100R002) Hardware Description 12 TDMoP card TDMoP card This chapter describes the TDMoP card of the iTN2100, including the following section:  iTN2100-CES-16E1T1-BL Raisecom Technology Co., Ltd.
  • Page 107: Itn2100-Ces-16E1T1-Bl

    Support clock recovery mechanism, including the self-adaptive clock, line recovery clock, system clock, and exterior clock.  Support configuring AC alarm transparent transmission or termination.  Support hot swapping. 12.1.2 Slots The iTN2100-CES-16E1T1-BL can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 108: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 12 TDMoP card 12.1.3 Interfaces Interface types There are 17 interfaces on the iTN2100-CES-16E1T1-BL panel, as listed in Table 12-1. Table 12-1 Interfaces on the iTN2100-CES-16E1T1-BL panel Interface Type Description – MiniUSB Debugging interface 1–16 RJ45 E1 balanced interface.
  • Page 109: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 12 TDMoP card Table 12-3 LEDs on the iTN2100-CES-16E1T1-BL panel Status Description Green Power LED  Green: the power supply is normal.  Off: the power supply is abnormal. Green System status LED  Green: the system is working improperly.
  • Page 110: Eop Cards

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards EOP cards This chapter describes EOP cards of the iTN2100, including the following sections:  OPCOM3500E-EOPFE  OPCOM3500E-EOP3FE  OPCOM3500E-EOP8FX  OPCOM3500E-EOP-FE16E1  OPCOM3500E-EOP-FEE1× 8  OPCOM3500E-EOP-FXE1× 8  OPCOM3500E-EOPS-8E1  OPCOM3500E-HT-6FE24E1 ...
  • Page 111: Opcom3500E-Eopfe

    Support the framed mode. It supports FAS+CRC4 PCM31 mode and CRC self- adaption. You can configure them.  Support E1 loopback detection and BERT.  Support hot swapping. 13.1.2 Slots The OPCOM3500E-EOPFE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 112: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.1.3 Interfaces Interface types There are 2 interfaces on the OPCOM3500E-EOPFE panel, as listed in Table 13-1. Table 13-1 Interfaces on the OPCOM3500E-EOPFE panel Interface Type Description – MiniUSB Debugging interface RJ45 Used for transmitting 1-way 100 Mbit/s Ethernet services.
  • Page 113: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Status Description 100M Green Ethernet electrical interface 100 Mbit/s LED  Green: the Ethernet rate is 100 Mbit/s.  Off: the Ethernet rate is 10 Mbit/s or the connection fails. LNK/ACT Green Ethernet electrical interface working LED ...
  • Page 114: Table 13-5 Specifications Of The Opcom3500E-Eopfe

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Table 13-5 Specifications of the OPCOM3500E-EOPFE Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.5 kg Max. power consumption 18 W Raisecom Technology Co., Ltd.
  • Page 115: Opcom3500E-Eop3Fe

    Support the framed mode. It supports FAS+CRC4 PCM31 mode and CRC self- adaption. You can configure them.  Support E1 loopback detection and BERT.  Support hot swapping. 13.2.2 Slots The OPCOM3500E-EOP3FE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 116: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.2.3 Interfaces Interface types There are 4 interfaces on the OPCOM3500E-EOP3FE panel, as listed in Table 13-6. Table 13-6 Interfaces on the OPCOM3500E-EOP3FE panel Interface Type Description – MiniUSB Debugging interface ...
  • Page 117: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.2.4 LEDs There are 8 LEDs on the OPCOM3500E-EOP3FE panel, as listed in Table 13-9. Table 13-9 LEDs on the OPCOM3500E-EOP3FE panel Status Description Green Power LED  Green: the power supply is normal.
  • Page 118: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Alarm Cause Level E1 LOF Data sent by the upstream node is incorrect, Critical because services are configured improperly or the hardware fails. E1 CRC An Error on data during transmission. Critical...
  • Page 119: Opcom3500E-Eop8Fx

    Support complete alarm and performance monitoring functions.  Support upgrading the card software online.  Support querying default configurations.  Support hot swapping. 13.3.2 Slots The OPCOM3500E-EOP8FX can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 120: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.3.3 Interfaces Interface types There are 9 interfaces on the OPCOM3500E-EOP8FX panel, as listed in Table 13-12. Table 13-12 Interfaces on the OPCOM3500E-EOP8FX panel Interface Type Description – MiniUSB Debugging interface 1–8...
  • Page 121: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Status Description LNK/ACT Green Ethernet interface working LED (1–8)  Green: the Ethernet interface is properly connected.  Off: the Ethernet interface is improperly connected or disconnected.  Blinking green: the Ethernet interface is receiving or sending data.
  • Page 122: Opcom3500E-Eop-Fe16E1

    Support the framed mode. It supports FAS+CRC4 PCM31 mode and CRC self-adaption. You can configure them.  Support E1 loopback detection and BERT.  Support hot swapping. 13.4.2 Slots The OPCOM3500E-EOP-FE16E1 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 123: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.4.3 Interfaces Interface types There is an interface on the OPCOM3500E-EOP-FE16E1 panel, as listed in Table 13-16. Table 13-16 The interface on the OPCOM3500E-EOP-FE16E1 panel Interface Type Description – RJ45 electrical interface...
  • Page 124: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Status Description LNK/ACT Green Ethernet electrical interface working LED  Green: the Ethernet electrical interface is properly connected.  Off: the Ethernet electrical interface is improperly connected or disconnected.  Blinking green: the Ethernet electrical interface is receiving or sending data.
  • Page 125: Table 13-20 Specifications Of The Opcom3500E-Eop-Fe16E1

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Table 13-20 Specifications of the OPCOM3500E-EOP-FE16E1 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.7 kg Max. power consumption 13 W Raisecom Technology Co., Ltd.
  • Page 126: Opcom3500E-Eop-Fee1×8

    100BASE-TX interface on the front panel.  The eight 100BASE-TX interfaces correspond to eight E1 channels respectively and independently.  Support hot swapping. 13.5.2 Slots The OPCOM3500E-EOP-FEE1× 8 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 127: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.5.3 Interfaces Interface types There are eight interfaces on the OPCOM3500E-EOP-FEE1× 8 panel, as listed in Table 13-21. Table 13-21 Interface on the OPCOM3500E-EOP-FEE1× 8 Interface Type Description – RJ45 electrical interface...
  • Page 128: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Interface Status Description LNK/ACT Green Link working LED (1–8)  Green: the link interface is properly connected.  Off: the link interface improperly connected or disconnected.  Blinking green: the link interface is receiving or sending data.
  • Page 129: Opcom3500E-Eop-Fxe1×8

    Support Automatical Laser Shutdown (ALS).  Support LPR detection.  Provide complete alarm and performance monitoring.  Support hot swapping. 13.6.2 Slots The OPCOM3500E-EOP-FXE1× 8 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 130: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.6.3 Interfaces Interface types There are eight interfaces on the OPCOM3500E-EOP-FXE1× 8 panel, as listed in Table 13-26. Table 13-26 Interfaces on the OPCOM3500E-EOP-FXE1× 8 panel Interface Type Description 1–8 SFP optical interface...
  • Page 131: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Interface Status Description LNK/ACT Green Link working LED (1–8)  Green: the link interface is properly connected.  Off: the link interface improperly connected or disconnected.  Blinking green: the link interface is receiving or sending data.
  • Page 132 Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Parameter Value Weight 0.35 kg Max. power consumption 15 W Raisecom Technology Co., Ltd.
  • Page 133: Opcom3500E-Eops-8E1

    Support managing any Raisecom RC95x family remote protocol convertor regardless whether the device is directly connected or connected through a device from other vendors.  Support hot swapping. 13.7.2 Slots The OPCOM3500E-EOPS-8E1 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 134: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.7.3 Interfaces Interface types There is an interface on the OPCOM3500E-EOPS-8E1 panel, as listed in Table 13-31. Table 13-31 The interface on the OPCOM3500E-EOPS-8E1 panel Interface Type Description – DB37 male connector...
  • Page 135: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Status Description Green System status LED  Green: the system is working improperly.  Off: the system is working improperly.  Blinking green: the system is working properly. Overall alarm LED ...
  • Page 136: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.7.7 Specifications Table 13-36 lists specifications of the OPCOM3500E-EOPS-8E1. Table 13-36 Specifications of the OPCOM3500E-EOPS-8E1 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight 0.4 kg Max.
  • Page 137: Opcom3500E-Ht-6Fe24E1

    E1 interface.  Support remote NMS for remote protocol converters and attached Ethernet transceivers.  Support hot swapping. 13.8.2 Slots The OPCOM3500E-HT-6FE24E1 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 138: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.8.3 Interfaces Interface types There are eight interfaces on the OPCOM3500E-EOP-FXE1× 8 panel, as listed in Table 13-37. Table 13-37 Interfaces on the OPCOM3500E-HT-6FE24E1 panel Interface Type Description 1–6 RJ45 Six ways of EF electrical interfaces...
  • Page 139: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards Interface Status Description LNK/ACT Green Link working LED (1–6)  Green: the link interface is properly connected.  Off: the link interface improperly connected or disconnected.  Blinking green: the link interface is receiving or sending data.
  • Page 140: Itn2100-Eot-Gestm4

    Support accessing the SDH network through the aggregation card. However, the card must be inserted into slot 2 or slot 4 of the iTN2100. 13.9.2 Slots The iTN2100-EOT-GESTM4 can be plugged into slots 1–5, 8, 11, and 12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 141: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.9.3 Interfaces Interface types There are five interfaces on the iTN2100-EOT-GESTM4 panel, as listed in Table 13-42. Table 13-42 Interfaces on the iTN2100-EOT-GESTM4 panel Interface Type Description 1–4 SFP optical interface Service uplink interfaces –...
  • Page 142: Dip Switches

    Off: no input LOS alarms are generated on optical interfaces 1, 2, 3, and 4. 13.9.5 DIP switches Table 13-45 lists configurations of the DIP switch on the iTN2100-EOT-GESTM4. Table 13-45 Configurations of the DIP switch on the iTN2100-EOT-GESTM4 Function...
  • Page 143: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 13 EOP cards 13.9.6 Alarms Table 13-46 lists alarms of the iTN2100-EOT-GESTM4. Table 13-46 Alarms of the iTN2100-EOT-GESTM4 Alarm Cause Level  The SFP optical module is removed. SFP absence alarm Critical  The SFP optical module is improperly installed.
  • Page 144: Specifications

    The remote device managed by the card generates Critical alarm loopback alarms. 13.9.7 Specifications Table 13-47 lists specifications of the iTN2100-EOT-GESTM4. Table 13-47 Specifications of the iTN2100-EOT-GESTM4 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight <...
  • Page 145: Eos Cards

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards EOS cards This chapter describes EOS cards of the iTN2100, including the following sections:  OPCOM3500E-EOS-4FE  OPCOM3500E-EOS-8FE  OPCOM3500E-4EOS-4FX  OPCOM3500E-8EOS-FE  OPCOM3500E-8EOS-FX Raisecom Technology Co., Ltd.
  • Page 146: Opcom3500E-Eos-4Fe

    Support complete alarms.  Support statistics of sent frames, received frames, and error packages of each VCG.  Support hot swapping. 14.1.2 Slots The OPCOM3500E-EOS-4FE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 147: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards 14.1.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-EOS-4FE panel, as listed in Table 14-1. Table 14-1 Interfaces on the OPCOM3500E-EOS-4FE panel Interface Type Description 1–4 RJ45 4 Ethernet electrical interfaces Interface parameters Table 14-2 lists parameters of interfaces 1–4 of the OPCOM3500E-EOS-4FE.
  • Page 148: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Interface Status Description Alarm LED  Red: TU-AIS and TU-LOP alarms are generated.  Off: no TU-AIS or TU-LOP alarm are generated. 100M Green Ethernet electrical interface rate LED (1-4)  Green: the interface is working at 100 Mbit/s.
  • Page 149: Opcom3500E-Eos-8Fe

    Support VCAT and LCAS.  Support online software upgrade for local devices.  Support complete alarms and performance monitoring.  Support hot swapping. 14.2.2 Slots The OPCOM3500E-EOS-8FE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 150: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards 14.2.3 Interfaces Interface types There are eight interfaces on the OPCOM3500E-EOS-8FE panel, as listed in Table 14-6. Table 14-6 Interfaces on the OPCOM3500E-EOS-8FE panel Interface Type Description – RJ45 8 FE interfaces Interface parameters Table 14-7 lists parameters of FE electrical interfaces on the OPCOM3500E-EOS-8FE.
  • Page 151: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Interface Status Description LNK/ACT Green Line working LED (1–8)  Green: the interface is working properly.  Off: the interface is disconnected or is working improperly.  Blinking green: the interface is receiving or sending data.
  • Page 152: Opcom3500E-4Eos-4Fx

    Support QoS priority overwriting.  Support interface discarding mode.  Support QoS based on DSCP.  Support bidirectional rate limiting.  Support hot swapping. 14.3.2 Slots The OPCOM3500E-4EOS-4FX can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 153: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards 14.3.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-4EOS-4FX panel, as listed in Table 14-10. Table 14-10 Interfaces on the OPCOM3500E-4EOS-4FX panel Interface Type Description  Each interface transmits a way of Ethernet optical 1–4...
  • Page 154: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Interface Status Description Green Optical signal detection LED (1–4)  Green: optical signals are detected.  Off: no optical signals are detected. LNK/ACT Green Line working LED (1–4)  Green: the interface is working properly.
  • Page 155: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Function Status Description switch Optical interface Bit1 Bit2 Bit3 Bit4 device SS25 SW2 is properly configured before the card leaves the factory. Do not configure it if not needed. 14.3.6 Alarms Table 14-15 lists alarms of the OPCOM3500E-4EOS-4FX.
  • Page 156: Opcom3500E-8Eos-Fe

    Support interface-based non-linear rate limiting ranging from 62 Kbit/s to 100 Mbit/s.  Support transparently transmitting BPDU, LACP, and 802.1x management frames.  Support hot swapping. 14.4.2 Slots The OPCOM3500E-8EOS-FE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 157: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards 14.4.3 Interfaces Interface types There is only one interface on the OPCOM3500E-8EOS-FE panel, as listed in Table 14-17. Table 14-17 Interface on the OPCOM3500E-8EOS-FE panel Interface Type Description – RJ45 Service downlink interface Interface parameters Table 14-18 lists parameters of the RJ45 interface on the OPCOM3500E-8EOS-FE.
  • Page 158: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Interface Status Description Alarm LED  Red: TU-AIS or TU-LOP alarm are generated in VC-12.  Off: no TU-AIS or TU-LOP alarm are generated in VC- 100M Green Ethernet electrical interface working LED ...
  • Page 159: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards SW2 is properly configured before the card leaves the factory. Do not configure it if not needed. Table 14-21 Configurations of DIP switch SW3 on the OPCOM3500E-8EOS-FE Function Status Description DIP bit...
  • Page 160: Opcom3500E-8Eos-Fx

    Support transparently transmitting BPDU, LACP, and 802.1x management frames.  Support remote NMS for RC500 and RC600 transceiver family.  Support hot swapping. 14.5.2 Slots The OPCOM3500E-8EOS-FX can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 161: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards 14.5.3 Interfaces Interface types There is only one interface on the OPCOM3500E-8EOS-FX, as listed in Table 14-24. Table 14-24 Interface on the OPCOM3500E-8EOS-FX panel Interface Type Description  Service downlink interface –...
  • Page 162: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Interface Status Description Green Optical signal detection LED  Green: optical signals are detected.  Off: no optical signals are detected. LNK/ACT Green Line working LED  Green: the interface is working properly.
  • Page 163: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 14 EOS cards Function Status Description DIP bit Ethernet Set the front plane interface to the egress services interface of Ethernet services. Bit3 Reserved Bit4 By default, Bit2 of SW3 is OFF. 14.5.6 Alarms Table 14-29 lists alarms of the OPCOM3500E-8EOS-FX.
  • Page 164: Pdh And Rcms Cards

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards PDH and RCMS cards This chapter describes PDH and RCMS cards of the iTN2100, including the following sections:  OPCOM3500E-16E1/16E1-BL  OPCOM3500E-32E1/32E1-BL  OPCOM3500E-P240EOS  OPCOM3500E-P240FE  OPCOM3500E-120EOS× 4 ...
  • Page 165: Opcom3500E-16E1/16E1-Bl

    The 4 figures are OPCOM3500E-16E1 (version A), OPCOM3500E-16E1 (version C), OPCOM3500E-16E1-BL (versions A and B), and OPCOM3500E- 16E1-BL (version C) from left to right. 15.1.2 Slots The OPCOM3500E-16E1/16E1-BL can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 166: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.1.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-16E1/16E1-BL, and the interfaces on the two cards are the same, as listed in Table 15-1. Table 15-1 Interfaces on the OPCOM3500E-16E1/16E1-BL panel...
  • Page 167: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description Green System status LED  Green: the system is working improperly.  Off: the system is working improperly.  Blinking green: the system is working properly. Overall alarm LED ...
  • Page 168: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.1.7 Specifications Table 15-6 lists specifications of the OPCOM3500E-16E1/16E1-BL. Table 15-6 Specifications of the OPCOM3500E-16E1/16E1-BL Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight <...
  • Page 169: Opcom3500E-32E1/32E1-Bl

    The OPCOM3500E-32E1-BL is a 32-way E1 electrical interface service card on the iTN2100, which can be set to balanced or unbalanced interface through software or the DIP switch. The latest configuration overwrites the previous one.
  • Page 170: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.2.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-32E1/32E1-BL, and the interfaces on the two cards are the same, as listed in Table 15-7. Table 15-7 Interfaces on the OPCOM3500E-32E1/32E1-BL panel...
  • Page 171: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description Green System status LED  Green: the system is working improperly.  Off: the system is working improperly.  Blinking green: the system is working properly. Overall alarm LED ...
  • Page 172: Cables

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-11 Alarms of the OPCOM3500E-32E1/32E1-BL Alarm Cause Level  Attenuation of received signals is over great. E1 LOS alarm Critical  The peer sender fails.  The fiber head is unclean or the connector is improperly connected.
  • Page 173: Opcom3500E-P240Eos

     Support LPR alarms.  Support ALS.  Support online software upgrade for local and remote devices.  Support hot swapping. 15.3.2 Slots The OPCOM3500E-P240EOS can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 174: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.3.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-P240EOS, as listed in Table 15-14. Table 15-14 Interfaces on the OPCOM3500E-P240EOS panel Interface Type Description  Service downlink interface A, B 1×...
  • Page 175 Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description WKB (L) Green Local optical interface B working LED  Green: local optical interface B is the working interface.  Off: local optical interface B is not the working interface.
  • Page 176: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description E-6 (R) Yellow Remote 10-6 error code alarm LED  Red: remote input signals have 10-6 error codes.  Off: remote input signals have no 10-6 error codes.
  • Page 177: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Alarm Cause Level Remote PDH overall The PDH optical interface on the remote device Critical alarm has overall alarms. 15.3.6 Specifications Table 15-17 lists specifications of the OPCOM3500E-P240EOS. Table 15-17 Specifications of the OPCOM3500E-P240EOS...
  • Page 178: Opcom3500E-P240Fe

     Support LPR alarms.  Support ALS.  Support online software upgrade for local and remote devices.  Support hot swapping. 15.4.2 Slots The OPCOM3500E-P240FE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 179: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.4.3 Interfaces Interface types There are three interfaces on the OPCOM3500E-P240FE panel, as listed in Table 15-18. Table 15-18 Interfaces on the OPCOM3500E-P240FE Interface Type Description RJ45 Service downlink interface ...
  • Page 180 Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description LNK/ACT Green Line working LED Green: the interface is working properly. Off: the interface is disconnected or is working improperly.  Blinking green: the interface is receiving or sending data.
  • Page 181: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description LOF (R) Remote LOF alarm LED  Red: input signal LOF alarms are generated on the remote optical interfaces.  Off: no input signal LOF alarms are generated on the remote optical interfaces.
  • Page 182: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Alarm Cause Level  Attenuation of received signals is over great. Local optical interface Major  The peer sender fails. E-6 alarm  The fiber head is unclean or the connector is improperly connected.
  • Page 183: Opcom3500E-120Eos×4

    Support LPR alarms.  Support ALS.  Support online software upgrade for local and remote devices.  Support hot swapping. 15.5.2 Slots The OPCOM3500E-120EOS× 4 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 184: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.5.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-120EOS× 4 panel, as listed in Table 15-22. Table 15-22 Interfaces on the OPCOM3500E-120EOS× 4 Interface Type Description  Service downlink interface A, B, C, D 1×...
  • Page 185: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.5.5 DIP switches Table 15-24, Table 15-25, and Table 15-26 list configurations of DIP switches on the OPCOM3500E-120EOS× 4. Table 15-24 Configurations of DIP switch SW2 on the OPCOM3500E-120EOS× 4...
  • Page 186: Table 15-26 Configurations Of Dip Switch Sw4 On The Opcom3500E-120Eos× 4

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-26 Configurations of DIP switch SW4 on the OPCOM3500E-120EOS× 4 Function Status Description DIP bit Set E1 local or Bit1 Set E1 local loopback on optical interface A. remote loopback on Set E1 remote loopback on optical interface optical interface A.
  • Page 187: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.5.6 Alarms Table 15-27 lists alarms of the OPCOM3500E-120EOS× 4. Table 15-27 Alarms of the OPCOM3500E-120EOS× 4 Alarm Cause Level  Attenuation of received signals is over great. Optical interface LOS Critical ...
  • Page 188: Table 15-28 Specifications Of The Opcom3500E-120Eos× 4

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-28 Specifications of the OPCOM3500E-120EOS× 4 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight < 0.45 kg Max. power consumption 10 W...
  • Page 189: Opcom3500E-120Eos×4L

    Support LPR alarms.  Support ALS.  Support online software upgrade for local and remote devices.  Support hot swapping. 15.6.2 Slots The OPCOM3500E-120EOS× 4L can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 190: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.6.3 Interfaces Interface types There are five interfaces on the OPCOM3500E-120EOS× 4L panel, as listed in Table 15-29. Table 15-29 Interfaces on the OPCOM3500E-120EOS× 4L Interface Type Description – MiniUSB Debugging interface ...
  • Page 191: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description LOS (1–4) Interface 1/2/3/4 LOS alarm LED  Red: input LOS alarms are generated on interface 1, 2, 3, or 4.  Off: no input LOS alarms are generated on interface 1, 2, 3, or 4.
  • Page 192: Opcom3500E-120Fe×4-Ge

    Support enabling or disabling MAC address learning based on interfaces.  Support configurable aging time ranging from 0s to 3825s.  Support online software upgrade.  Support hot swapping. 15.7.2 Slots The OPCOM3500E-120FE× 4-GE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 193: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.7.3 Interfaces Interface types There are five interfaces on the OPCOM3500E-120FE× 4-GE panel, as listed in Table 15-33. Table 15-33 Interfaces on the OPCOM3500E-120FE× 4-GE panel Interface Type Description RJ45 Service downlink interface ...
  • Page 194: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description Green Duplex mode LED  Green: the Ethernet interface is working in full duplex mode.  Off: the Ethernet interface is working in half duplex mode. LNK/ACT...
  • Page 195: Table 15-37 Configurations Of Dip Switch Sw3 On The Opcom3500E-120Fe× 4-Ge

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description switch Optical interface Bit1 Bit2 Bit3 Bit4 device SS13 SS15 SS23 SS25 SW2 is properly configured before the card leaves the factory. Do not configure it if not needed.
  • Page 196: Table 15-38 Configurations Of Dip Switch Sw4 On The Opcom3500E-120Fe× 4-Ge

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description Description – Bit8 Set the egress Set the egress interface of interface of aggregated Ethernet aggregated services to the FX interface Ethernet on the backplane. services. Set the egress interface of...
  • Page 197: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description DIP bit Bit7 Set E1 local or Set E1 local loopback on optical interface D. remote loopback on Set E1 remote loopback on optical interface optical interface D.
  • Page 198: Opcom3500E-120Fe×8L-Ge

    Support querying the MAC address table.  Support DDM of the SFP module.  Support storing and querying default configurations.  Support hot swapping. 15.8.2 Slots The OPCOM3500E-120FE× 8L-GE can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 199: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.8.3 Interfaces Interface types There are 10 interfaces on the OPCOM3500E-120FE× 8L-GE panel, as listed in Table 15-41. Table 15-41 Interfaces on the OPCOM3500E-120FE× 8L-GE panel Interface Type Description –...
  • Page 200: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.8.4 LEDs There are 20 LEDs on the OPCOM3500E-120FE× 8L-GE panel, as listed in Table 15-44. Table 15-44 LEDs on the OPCOM3500E-120FE× 8L-GE panel Status Description Green Power LED ...
  • Page 201: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-45 Alarms generated on the OPCOM3500E-120FE× 8L-GE Alarm Cause Level  Attenuation of received signals is over great. Optical interface LOS Critical  The peer sender fails on the optical interface.
  • Page 202: Opcom3500E-240Ge×4L

    Support saving and recovering service card configuration and support pre-configuring service cards.  Work with remote RCMS2903-4E1-4GE, RCMS2912-4E1T1GE, and RCMS2912- 8E1T1GE etc.  Support hot swapping. 15.9.2 Slots The OPCOM3500E-240GE× 4L can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 203: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.9.3 Interfaces Interface types There are nine interfaces on the OPCOM3500E-240GE× 4L panel, as listed in Table 15-47. Table 15-47 OPCOM3500E-240GE× 4L interfaces Identifier Interface type Description – MiniUSB Debugging interface 1–4 (GE)
  • Page 204: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Status Description LPR LED for remote device that is connected to related optical interfaces (1–4)  Red: the remote device is powered off, when the remote device, which is connected to the local device and optical interfaces (Line), is working properly.
  • Page 205: Opcom3500E-120H×4

    15.10.1 Appearance and functions Appearance Function The OPCOM3500E-120H× 4 is a multi-service multiplexing tributary card on the iTN2100. Now the OPCOM3500E-120H× 4 has two versions: A and  Support 4-way PDH optical signal access and each way supports four ways of E1 services.
  • Page 206: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.10.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-120H× 4 (Versions A and B) panel, as listed in Table 15-52. Table 15-52 Interfaces on the OPCOM3500E-120H× 4 (Versions A and B),...
  • Page 207: Dip Switches

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Status Description LOS (A–D) Related nterface LOS alarm LED LOS (1–4)  Red: input LOS alarms are generated on the related interface.  Off: no input LOS alarms are generated on the related interface.
  • Page 208: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description DIP bit ALS on the optical Disable ALS. interface. – – Bit2–Bit4 Reserved By default, SW7 is all OFF. Namely, ALS is disabled by default. Version B The OPCOM3500E-120H×...
  • Page 209: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-57 Alarms of the OPCOM3500E-120H× 4 (version A) Alarm Cause Level  Attenuation of received signals is over great. Optical interface LOS Critical  The peer sender fails on the optical interface.
  • Page 210: Table 15-60 Specifications Of The Opcom3500E-120H× 4 (Version B)

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Version B Table 15-60 lists specifications of the OPCOM3500E-120H× 4 (Version B). Table 15-60 specifications of the OPCOM3500E-120H× 4 (Version B) Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight <...
  • Page 211: Opcom3500E-240H×2

    Support E1 local and remote loopback.  Support LPR alarms for remote devices.  Support ALS.  Support hot swapping. 15.11.2 Slots The OPCOM3500E-240H× 2 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 212: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.11.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-240H× 2 panel, as listed in Table 15-61. Table 15-61 Interfaces on the OPCOM3500E-240H× 2 panel Interface Type Description ...
  • Page 213: Table 15-63 Configurations Of Dip Switch Sw2 On The Opcom3500E-240H× 2

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-63 Configurations of DIP switch SW2 on the OPCOM3500E-240H× 2 Function Status Description DIP bit Set E1 local or Bit1 Set E1 local loopback on optical interface A. remote loopback on Set E1 remote loopback on optical interface optical interface A.
  • Page 214: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description switch Optical interface Bit1 Bit2 Bit3 Bit4 device SS13 SS15 SS23 SS25 SW3 is properly configured before the card leaves the factory. Do not configure it if not needed.
  • Page 215: Opcom3500E-3Ds3/E3

    Support DS3 loopback detection.  Support E3 loopback detection.  Support BERT.  Support complete alarm and performance monitoring.  Support hot swapping. 15.12.2 Slots The OPCOM3500E-3DS3/E3 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 216: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards 15.12.3 Interfaces Interface types There are nine interfaces on the OPCOM3500E-3DS3/E3 panel, as listed in Table 15-67. Table 15-67 Interfaces on the OPCOM3500E-3DS3/E3 panel Interface Type Description – (1–3) SFP optical...
  • Page 217: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Parameter Description Line code HDB3 Electrical parameters Comply with ITU-T G.703 recommendations. Transferring feature Comply with ITU-T G.823 recommendations. Jitter capacity Comply with ITU-T G.823 recommendations. 15.12.4 LEDs There are 10 LEDs on the OPCOM3500E-3DS3/E3 panel, as listed in Table 15-70.
  • Page 218: Table 15-71 Configurations Of Dip Switch Sw1 On The Opcom3500E-3Ds3/E3

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Table 15-71 Configurations of DIP switch SW1 on the OPCOM3500E-3DS3/E3 Function Status Description switch Bit1 Bit2 Bit3 Bit4 – – Set the Set the card to 1+1 convert mode. working –...
  • Page 219: Alarms

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Function Status Description Remark local optical Disable interface outer loopback. – Bit5 Enable or disable Enable local electrical Disable interface outer loopback. – Bit6 Enable or disable Enable remote optical...
  • Page 220: Cables

    Raisecom iTN2100 (P100R002) Hardware Description 15 PDH and RCMS cards Interface Alarm Cause Level  No output transmitted signals. Minor alarm  Codes of received signals conflict. LCV alarm Minor  Timeslot of the backplane of VC12 E3 AIS Minor...
  • Page 221 Raisecom iTN2100 (P100R002) Hardware Description 16 V.24 card V.24 card This chapter describes the V.24 card on the iTN2100, including the following section:  OPCOM3500E-8V24 16-192 Raisecom Technology Co., Ltd.
  • Page 222: 24 Card

    16 V.24 card 16.1 OPCOM3500E-8V24 16.1.1 Appearance and functions Appearance Function The OPCOM3500E-8V24 is an 8-way V.24 data service card on the iTN2100.  Provide two HDB26 interfaces. Each interface transmits four ways of V.24 data.  Support application in DCE mode.
  • Page 223: Slots

    TS21 TS21–22 TS21–24 16.1.2 Slots The OPCOM3500E-8V24 can be plugged into slots 1–5 and 8–12 on the iTN2100. 16.1.3 Interfaces Interface types There are two interfaces on the OPCOM3500E-8V24 panel, as listed in Table 16-2. Table 16-2 Interfaces on the OPCOM3500E-8V24 panel...
  • Page 224: Cables

    Raisecom iTN2100 (P100R002) Hardware Description 16 V.24 card Interface Status Description Green System status LED  Green: the system is working improperly.  Off: the system is working improperly.  Blinking green: the system is working properly.  Blinking green: V.24 data channel interface 1/2/.../7/8 is sending Green data from itself to the DTE device.
  • Page 225 Raisecom iTN2100 (P100R002) Hardware Description 17 V.35 card V.35 card This chapter describes the V.35 card on the iTN2100, including the following sections:  OPCOM3500E-8V35 Raisecom Technology Co., Ltd.
  • Page 226: 35 Card

    Support E1 BERT. When you send test codes to the backplane, you can test only one E1 once.  Support hot swapping. 17.1.2 Slots The OPCOM3500E-8V35 can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 227: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 17 V.35 card 17.1.3 Interfaces Interface types There are four interfaces on the OPCOM3500E-8V35 panel, as listed in Table 17-1. Table 17-1 Interfaces on the OPCOM3500E-8V35 panel Interface Connector type Description  Service downlink interface –...
  • Page 228: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 17 V.35 card 17.1.6 Specifications Table 17-4 lists specifications of the OPCOM3500E-8V35. Table 17-4 Specifications of the OPCOM3500E-8V35 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight < 0.45 kg Max.
  • Page 229: Crossconnection Card

    Raisecom iTN2100 (P100R002) Hardware Description 18 64K crossconnection card 64K crossconnection card This chapter describes the 64K cross connection card on the iTN2100, including the following section:  OPCOM3500E-DXC-DS0 Raisecom Technology Co., Ltd.
  • Page 230: Opcom3500E-Dxc-Ds0

    Support outer loopback on the E1 interface. You can perform loopback on E1 signals from other service cards.  The iTN2100 can be plugged into with multiple 64K cross connection cards. Any two of them support card-level hot backup. ...
  • Page 231: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 18 64K crossconnection card 18.1.3 LEDs There are three LEDs on the OPCOM3500E-DXC-DS0 panel, as listed in Table 18-1. Table 18-1 LEDs on the OPCOM3500E-DXC-DS0 panel Interface Status Description Green Power LED  Green: the power supply is normal.
  • Page 232: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 18 64K crossconnection card 18.1.5 Specifications Table 18-3 lists specifications of the OPCOM3500E-DXC-DS0. Table 18-3 Specifications of the OPCOM3500E-DXC-DS0 Parameter Value Dimensions 25 mm (width) × 232 mm (depth) × 240 mm (height) Weight < 0.36 kg Max.
  • Page 233: Multi-Service Cards

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Multi-service cards This chapter describes the multi-service cards of the iTN2100, including the following sections:  OPCOM3500E-12MT  OPCOM3500E-MULTI Raisecom Technology Co., Ltd.
  • Page 234: Opcom3500E-12Mt

    Do avoid short-circuit during operation. If short-circuit occurs and the ring time is over 10 minutes, the card will be damaged. 19.1.2 Slots The OPCOM3500E-12MT can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 235: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards 19.1.3 Interfaces Interface types There are 12 interfaces on the OPCOM3500E-12MT panel, as listed in Table 19-1. Table 19-1 Interfaces on the OPCOM3500E-12MT panel Interface Type Description 1–12 HDB26 female connector Access 12-way magnetic telephone interfaces.
  • Page 236: Figure 19-1 Interface Pins Of The Opcom3500E-12Mt

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Parameter Description Idle-channel noise < -67 dBm0p Ring current voltage Typical 75Vac sine wave/30 Hz Return loss > 12 dB (300 Hz–600 Hz) > 15 dB (600 Hz–3400 Hz) Interface pins Figure 19-1 shows interface pins of the OPCOM3500E-12MT.
  • Page 237: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards HDB26M pin Definition Description CH-07B CH-08A -way voice CH-08B CH-09A -way voice CH-09B CH-10A -way voice CH-10B CH-11A -way voice CH-11B CH-12A - way voice CH-12B – Idle – Idle 19.1.4 LEDs There are 26 LEDs on the OPCOM3500E-12MT panel, as listed in Table 19-4.
  • Page 238: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Status Description Green Signaling input LED  Green: there is signaling being input.  Off: no signaling is being input. The signaling direction is based on the magnetic telephone. RX refers the direction from the 12MT to the magnetic telephone.
  • Page 239: Opcom3500E-Multi

    In RS485/RS422 mode, sampling frequency of interfaces can be set to 64 KHz or 128 KHz and the related speeds are set to 9.6 Kbit/s and 19.2 Kbit/s.  Support upgrading the card online. 19.2.2 Slots The OPCOM3500E-MULTI can be plugged into slots 1–5 and 8–12 on the iTN2100. Raisecom Technology Co., Ltd.
  • Page 240: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards 19.2.3 Interfaces Interface types There are 3 interfaces on the OPCOM3500E-MULTI panel, as listed in Table 19-7. Table 19-7 Interfaces on the OPCOM3500E-MULTI panel Interface Type Description One RJ45 interface outputs 4-way FXS/FXO voice...
  • Page 241: Table 19-9 Parameters Of 2/4W Interfaces On The Opcom3500E-Multi

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Parameter Description Δ< 3.0 dB (-50 dBm0 to -55 dBm0) Degree of unbalance about > 40 dB (300 Hz–600 Hz) earth > 46 dB (600 Hz–2400 Hz) > 41 dB (2400 Hz–3400 Hz) Idle-channel noise <...
  • Page 242: Table 19-10 Parameters Of V.24 Interfaces On The Opcom3500E-Multi

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Parameter Description Degree of unbalance about > 40 dB (300 Hz–600 Hz) earth > 46 dB (600 Hz–2400 Hz) > 41 dB (2400 Hz–3400 Hz) Idle-channel noise < -67 dBm0 Feeding voltage (on-hook)
  • Page 243: Table 19-12 Relationship Between The Maximum Speed And Occupied Transmission Bandwidth Of Rs232 Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Table 19-12 list the relationship between the maximum speed and occupied transmission bandwidth of RS232 interfaces Table 19-12 Relationship between the maximum speed and occupied transmission bandwidth of RS232 interfaces Occupied transmission...
  • Page 244: Table 19-15 2/4W Interface Pins Of The Opcom3500E-Multi

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards RJ45 RJ45 pin No. Line name Description RING3 TIP4 -way voice RING4 Table 19-15 describes 2/4W interface pins of the OPCOM3500E-MULTI. Table 19-15 2/4W interface pins of the OPCOM3500E-MULTI HDB26M HDB26 pin...
  • Page 245: Table 19-16 Data Interface Pins Of The Opcom3500E-Multi

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards HDB26M HDB26 pin Definition Mark Description  4-wire: 4 -way voice frequency transmitting A T/RA_4  2-wire: receiving/transmitting A  4-wire: 4 -way voice frequency transmitting B T/RB_4  2-wire: receiving/transmitting B...
  • Page 246: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards RS232 pin V.24 pin RS422 pin RS485 pin Mark Description Mark Description Mark Description Mark Description TXD_ TX_2 T/RX_ TX_2 -way -way -way data -way data transmitting transmitting T/RX_ and receiving –...
  • Page 247: Dip Switch

    Green If the 4 LEDs are in green, it indicates that the MULTI- FXS, MULTI-FXO, MULTI-V24, and MULTI-RS485 V24 RS485 are inserted into the iTN2100. Indicate the usage status of the voice channel. The LED IN-USE 1–8 Green is lighten up for local off-hook (outputting signaling), local ringing (inputting signaling), and conversation.
  • Page 248: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 19 Multi-service cards Service BIT of Description Configure the duplex mode Half-duplex of the RS485 interface. (RS485) Full duplex (RS422) Set the bandwidth. 64 Kbit/s 128 Kbit/s 19.2.6 Specifications Table 19-19 lists specifications of the OPCOM3500E-MULTI.
  • Page 249: Service Aggregation Cards

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards Service aggregation cards This chapter describes the service aggregation cards of the iTN2100, including the following sections:  iTN2100-Gb  iTN2100-8SU-S  iTN2100-4SU-D Raisecom Technology Co., Ltd.
  • Page 250: Itn2100-Gb

    (the peer device).  Support hot swapping. Except for card name printed on the panel, all models of the iTN2100-Gb (A) and the ones of the iTN2100-Gb (B) are identical. This guide takes the iTN2100-Gb-s for an example.
  • Page 251: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards 20.1.3 Interfaces Interface types There are 5 interfaces on the iTN2100-Gb panel, as listed in Table 20-1. Table 20-1 Interfaces on the iTN2100-Gb panel Interface Type Description  Client-side interface CLIENT 1–4 SFP interface ...
  • Page 252 Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards SFP module model Central TX Overload Transmis module wavelength power power sensitivity sion (nm) (dBm) (dBm) (dBm) distance (Km) USFP-Gb/S1-D-R 1310 -10 to -3 > -3 < -21 USFP-Gb/LH1-D-R 1310 -4 to 0 >...
  • Page 253 Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards SFP module model Central TX Overload Transmis module wavelength power power sensitivity sion (nm) (dBm) (dBm) (dBm) distance (Km) CSFP-48 CSFP-48/S/xx-D-R 1471, 1491, 0 to +5 > -3 < -18 (xx = 47, 49, 51, 53,...
  • Page 254: Leds

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards  Line-side interface metrics Line-side interface metrics vary on the iTN2100 cards. Table 20-4 lists line-side interface metrics. Table 20-4 Line-side interface metrics Single- Single- Transmis Card model sion wavelength wavelength...
  • Page 255: Dip Switches

    20.1.5 DIP switches Functions of DIP switches Definition on the DIP switch of the iTN2100-Gb (A) and iTN2100-Gb (B) is identical. SW2, SW3, SW4, and SW5 are used to configure client-side interfaces 1–4 respectively. Each DIP switch has 8 BITs and related BITs have the identical functions. Table 20-6 lists BITs 1–8 of the DIP switch.
  • Page 256: Table 20-3 Client-Side Interface Metrics (Electrical Modules)

    For details, see Table 20-2 Client-side interface metrics (optical modules), Table 20-3 Client-side interface metrics (electrical modules), and Table 20-4 Line-side interface metrics. Configurations on DIP switches Table 20-7 describes configurations on DIP switches of the iTN2100-Gb (A). Raisecom Technology Co., Ltd.
  • Page 257: Table 20-7 Configurations On Client-Side Interfaces Of The Itn2100-Gb (A)

    NView NNM system, DIP switch configurations are valid. Otherwise, configurations through the NView NNM system take effect.  The iTN2100-Gb cards must be used in pair. In addition, configurations on related interfaces of the 2 card must be identical. ...
  • Page 258: Table 20-8 Configurations On Client-Side Interfaces Of The Itn2100-Gb (B)

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards Table 20-8 describes configurations on DIP switches of the iTN2100-Gb (B). Table 20-8 Configurations on client-side interfaces of the iTN2100-Gb (B) Client-side SFP module Configuration Recommended signal switch configuration – STM-16...
  • Page 259: Specifications

    NView NNM system, DIP switch configurations are valid. Otherwise, configurations through the NView NNM system take effect.  The iTN2100-Gb cards must be used in pair. In addition, configurations on related interfaces of the 2 card must be identical. ...
  • Page 260: Table 20-11 Ordering Information Of The Itn2100-Gb (B)

    2.66 Gbit/s  S: short-distance and left  S-R: short-distance and right Ordering information of SFP modules The following SFP modules are available for the iTN2100-Gb (A):  1000BASE-X optical module  1000BASE-T electrical module  10/100/1000BASE-T auto-negotiation electrical module ...
  • Page 261 Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards Type Wavelength (nm) Model USFP-Gb/SS24-D-R USFP-Gb/SS25-D-R USFP-Gb/SS34-D-R USFP-Gb/SS35-D-R TX wavelength: 1471 nm, 1491 nm, CSFP-Gb/S/xx-D-R 1511 nm, 1531 nm, 1551 nm, 1571 (xx = 47, 49, 51, 53, 55, 57, nm, 1591 nm, and 1611 nm, relating...
  • Page 262: Table 20-13 Ordering Information Of Electrical Modules

    Transmission distance: 100 m  Connector: RJ45 When the iTN2100-Gb (B) uses a SFP module whose speed is smaller than 2.5 Gbit/s, it cannot reach the maximum transmission speed 2.66 Gbit/s. The real transmission speed depends on the used SFP module.
  • Page 263: Itn2100-8Su-S

    Appearance Function The iTN2100-8SU-S card can be used to multiplex or de-multiplex 8 CWDM wavelength optical signals. The 8-wavelength CWDM system can efficiently use the bandwidth of the fiber to prevent laying fibers repeatedly. This helps save costs. The 8 wavelength channels are 1471 nm, 1491 nm, 1511 nm, 1531 nm, 1551 nm, 1571 nm, 1591 nm, and 1611 nm.
  • Page 264: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards 20.2.3 Interfaces There are 9 interfaces on the iTN2100-8SU-S panel, as listed in Table 20-14. Table 20-14 interfaces on the iTN2100-8SU-S panel Interface Type Description  Line-side interface LINE SC/PC connector ...
  • Page 265: Specifications

    Storage temperature of optical module (° C) -40 to 85 20.2.7 Networking applications The iTN2100-8SU-S card can cooperate with Raisecom iTN2100 series devices to form a point-to-point, point-to-multipoint, link-like, or ring network topology, meeting networking requirements of multiple telecommunication networks. The iTN2100-8SU-S card also can...
  • Page 266: Figure 20-1 Point-To-Point Networking Application With The Itn2100-8Su-S

    8 wavelength channels at the client side and transmits the multiplexed signals to Node A. After receiving optical signals, Node A de-multiplexes these signals and then sends them out. In this mode, the iTN2100-8SU-S can be used to transmit services between Node A and Node B.
  • Page 267: Ordering Information

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards Figure 20-2 OADM ring network with the iTN2100-8SU-S 20.2.8 Ordering information Table 20-18 lists ordering information of the iTN2100-8SU-S. Table 20-18 Ordering information of the iTN2100-8SU-S Model Hardware version Description iTN2100-8SU-S A.10...
  • Page 268: Itn2100-4Su-D

    The iTN2100-4SU-D is a 4-way dual-fiber CWDM multiplexing/de-multiplexing card. It can realize bidirectional multiplexing transmission of 4 CWDM wavelength optical signals in 2 fibers. The iTN2100-4SU-D can efficiently use the bandwidth of the fiber to prevent laying fibers repeatedly. This helps save costs.
  • Page 269: Interfaces

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards 20.3.3 Interfaces There are 5 interfaces on the iTN2100-4SU-D panel, as listed in Table 20-19. Table 20-19 Interfaces on the iTN2100-4SU-D panel Interface Type Description  Line-side interface, used for receive/send LINE 1×...
  • Page 270: Optical Performance Metrics

    Device B multiplexes optical signals of 4 wavelength channels at the client side and transmits the multiplexed signals to Device A. After receiving optical signals, Device A de-multiplexes these signals and then sends them out. Figure 20-3 shows a point-to-point networking application with the iTN2100-4SU-D. Raisecom Technology Co., Ltd.
  • Page 271: Figure 20-3 Point-To-Point Networking Application With The Itn2100-4Su-D

    Figure 20-3 Point-to-point networking application with the iTN2100-4SU-D OADM ring network At the local, the iTN2100-4SU-D multiplexes optical signals of 4 wavelength channels (1511 nm, 1531 nm, 1551 nm, and 1571 nm) and provides routing protection by establishing an OADM ring network. Access points A–D can perform bidirectional add/drop multiplexing on 1-way optical signals.
  • Page 272: Ordering Information

    Raisecom iTN2100 (P100R002) Hardware Description 20 Service aggregation cards 20.3.8 Ordering information Table 20-23 lists ordering information of the iTN2100-4SU-D. Table 20-23 Ordering information of the iTN2100-4SU-D Model Hardware version Description iTN2100-4SU-D A.00 Four-way dual-fiber CWDM multiplexing/de-multiplexing card Raisecom Technology Co., Ltd.
  • Page 273: Cables

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Cables This chapter describes cables used by the iTN2100, including the following sections:  Fiber  Ethernet cables  Configuration cables  DC power cables  AC power cables  Grounding cables ...
  • Page 274: Appearance

    2 mm single-mode fiber 2 mm multi-mode fiber 21.1.2 Appearance Figure 21-1 shows the LC/PC fiber connector used by the iTN2100. Figure 21-1 LC/PC fiber connector When connecting or removing the LC/PC optical connector, align the connector with the optical interface, and do not rotate the fiber. Pay attention to the following points: ...
  • Page 275: Ethernet Cables

     To remove the fiber, press the latch on the connector and pull the fiber out. Figure 21-3 shows the FC/PC fiber connector used by the iTN2100. Figure 21-3 FC/PC fiber connector When connecting or removing the FC/PC optical connector, pay attention to the following points: ...
  • Page 276: Specifications

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-4 Ethernet cable 21.2.3 Specifications The Ethernet cables have two types:  Straight-through cable: used to connect devices of different types, such as a PC and a switch/switch and router.  Crossover cable: used to connect devices of the same type, such as between 2 PCs/switches/routers, or between a PC and a router (they are divided into the same group) Table 21-2 lists the line order of EIA/TIA568A and EIA/TIA568B standards.
  • Page 277: Figure 21-5 Line Order Of The Straight-Through Cable

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-5 Line order of the straight-through cable Crossover cable The line order for 100 Mbit/s crossover cable is different from that of 1000 Mbit/s crossover cable. One RJ45 connector of the 100 Mbit/s crossover cable follows EIA/TIA568A standard; the other RJ45 connector follows EIA/TIA568B standard line order.
  • Page 278: Figure 21-7 Line Order Of The 1000 Mbit/S Crossover Cable

    PIN6, PIN4 to PIN7, and PIN5 to PIN8, as shown in Figure 21-7. Figure 21-7 Line order of the 1000 Mbit/s crossover cable Raisecom provides straight-through cables and 100 Mbit/s crossover cable which are different in name only. The straight-through cable is named as CBL-ETH-RJ45/RJ45-D while the crossover cable is named as CBL-ETH-RJ45/RJ45-X-D Table 21-3 lists technical specifications of the Ethernet cable.
  • Page 279: Configuration Cables

    (P100R002) Hardware Description 21 Cables 21.3 Configuration cables 21.3.1 Introduction The configuration cable is used to connect the Console interface on the iTN2100 to the PC that runs terminal emulation program. You can configure the iTN2100 through command lines. 21.3.2 Appearance Use the DB-9 connector and RJ45 connector as configuration cable connectors for the iTN2100, as shown in Figure 21-8.
  • Page 280: Appearance

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.4.2 Appearance The DC power supply cable consists of DC connectors and co-axial cable, as listed in Figure 21-9. Figure 21-9 DC power cable 21.4.3 Specifications Table 21-5 lists specifications of the DC power cable.
  • Page 281: Appearance

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.5.2 Appearance Figure 21-10 shows the European standard AC cable. Figure 21-10 European standard AC cable Figure 21-11 shows the American standard AC cable. Figure 21-11 American standard AC cable 21.5.3 Technical specifications Table 21-7 lists specifications of the European standard AC power cable.
  • Page 282: Grounding Cables

    21.6 Grounding cables 21.6.1 Introduction The grounding cable is used to ground the iTN2100 chassis. 21.6.2 Appearance The grounding cable of the iTN2100 consists of OT terminals and co-axial cable, as listed in Figure 21-12. Figure 21-12 Grounding cable 21.6.3 Specifications Table 21-9 lists specifications of the grounding cable of the iTN2100.
  • Page 283: Alarm Cables

    21.7.1 Introduction The alarm cable is used to connect alarm terminals to other devices for inputting or outputting alarm signals. The alarm terminal of the iTN2100 is a 4-hole spring terminal. 21.7.2 PIN Figure 21-13 shows pins of the alarm terminal.
  • Page 284: Specifications

    21.9 E1-DB37 cables 21.9.1 Introduction The E1-DB37 cable is used to connect the DB37 male connector of the iTN2100 and other devices to transmit E1 services. Table 21-12 lists relations between the E1-DB37 cable and the card on the iTN2100.
  • Page 285: Figure 21-15 Cbl-E1-Db37F (40)/16Nc Cable

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-15 CBL-E1-DB37F (40)/16NC cable Specifications Table 21-13 lists technical specifications of the CBL-E1-DB37F(40)/16NC cable. Table 21-13 Technical specifications of the CBL-E1-DB37F(40)/16NC cable Parameter Description Name CBL-E1-DB37F (40)/16NC Connector DB37 female connector Type 75-ohm 16-core co-axial cable Table 21-14 lists definitions of pins on the CBL-E1-DB37F(40)/16NC cable.
  • Page 286: Cbl-E1-Db37F/16Bncf

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Definition Mark Definition Mark OUT5- IN5- OUT5+ IN6+ OUT6- IN6- OUT6+ IN7+ OUT7- IN7- OUT7+ IN8+ OUT8- IN8- – – OUT8+ – –  The PIN marked "+" is connected to the core of the co-axial cable.
  • Page 287: Cbl-E1-Db37F/16Bncm

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Parameter Description Connector DB37 female connector, or BNC female connector Type 75-ohm 16-core co-axial cable 21.9.4 CBL-E1-DB37F/16BNCM Appearance Figure 21-17 shows the CBL-E1-DB37F/16BNCM cable. Figure 21-17 CBL-E1-DB37F/16BNCM cable Specifications Table 21-16 lists specifications of the CBL-E1-DB37F/16BNCM cable.
  • Page 288: E1-Scsi100 Cables

    The E1-SCSI100 cable is used to connect the SCSI female connector (100 pin) of the iTN2100 and other devices to transmit E1 services. Table 21-18 lists relations between the E1-SCSI100 cable and the card on the iTN2100. Table 21-18 Relations between the E1-SCSI100 cable and the card on the iTN2100...
  • Page 289: Cbl-E1-Scsi100M (40)/32Bncf

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.10.2 CBL-E1-SCSI100M (40)/32BNCF Appearance Figure 21-19 shows the CBL-E1-SCSI100M(40)/32BNCF cable. Figure 21-19 CBL-E1-SCSI100M(40)/32BNCF cable Specifications Table 21-19 lists specifications of the CBL-E1-SCSI100M(40)/32BNCF cable. Table 21-19 Specifications of the CBL-E1-SCSI100M(40)/32BNCF cable Parameter Description Name...
  • Page 290: Cbl-E1-Scsi100M (40)/16Rj45

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-20 CBL-E1-SCSI100M(40)/32BNCM cable Specifications Table 21-20 lists specifications of the CBL-E1-SCSI100M (40)/32BNCM cable. Table 21-20 Specifications of the CBL-E1-SCSI100M (40)/32BNCM cable Parameter Description Name CBL-E1-SCSI100M (40)/32BNCM Connector SCSI100P male connector, or BNC male connector Type SYFVZP-75-1-1×...
  • Page 291: V24-Hdb26 Cables

    21.11 V24-HDB26 cables 21.11.1 Introduction The V24-HDB26 cable is used to connect the HDB26 female connector of the iTN2100 and other device to transmit V24 services. Table 21-22 lists relations between the V24-HDB26 cable and the card on the iTN2100.
  • Page 292: Cbl-V24-Hdb26M/4Db25F

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.11.2 CBL-V24-HDB26M/4DB25F Appearance Figure 21-22 shows the CBL-V24-HDB26M/4DB25F cable. Figure 21-22 CBL-V24-HDB26M/4DB25F cable Specifications Table 21-23 lists specifications of the CBL-V24-HDB26M/4DB25F cable. Table 21-23 Specifications of the CBL-V24-HDB26M/4DB25F cable Parameter Description Name CBL-V24-HDB26M/4DB25F...
  • Page 293: Pin

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-23 CBL-V24-HDB26M/4DB25M cable Specifications Table 21-24 lists specifications of the CBL-V24-HDB26M/4DB25M cable. Table 21-24 Specifications of the CBL-V24-HDB26M/4DB25M cable Parameter Description Name CBL-V24-HDB26M/4DB25M Connector HDB26 male connector, or DB25 female connector Type 9-core data cable 21.11.4 PIN...
  • Page 294: V35-Hdb26 Cables

    V.35 services. The unshielded cable is used on V.35 interface card to ensure lightning protection. Table 21-26 lists relations between the V35-HDB26 cable and the card on the iTN2100. Table 21-26 Relations between the V35-HDB26 cable and the card on the iTN2100...
  • Page 295: Cbl-V35-Hdb26M/2M34F

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Card Cable CBL-V35-HDB26M/DB25M (unshielded cable) 21.12.2 CBL-V35-HDB26M/2M34F Appearance Figure 21-24 shows the CBL-V35-HDB26M/2M34F cable. Figure 21-24 CBL-V35-HDB26M/2M34F cable Specifications Table 21-27 lists specifications of the CBL-V35-HDB26M/2M34F cable. Table 21-27 Specifications of the CBL-V35-HDB26M/2M34F cable...
  • Page 296: Cbl-V35-Hdb26M/M34F

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-25 CBL-V35-HDB26M/2M34M cable Specifications Table 21-28 lists specifications of the CBL-V35-HDB26M/2M34M cable. Table 21-28 Specifications of the CBL-V35-HDB26M/2M34M cable Parameter Description Name CBL-V35-HDB26M/2M34M Connector HDB26 male connector, or M34 female connector Type 9.5P+1+B+AL cable...
  • Page 297: Cbl-V35-Hdb26M/M34M

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Table 21-29 Specifications of the CBL-V35-HDB26M/M34F cable Parameter Description Name CBL-V35-HDB26M/M34F Connector HDB26 male connector, or M34 female connector Type 9.5P+1+B+AL cable 21.12.5 CBL-V35-HDB26M/M34M Appearance Figure 21-27 shows the CBL-V35-HDB26M/M34M cable. Figure 21-27 CBL-V35-HDB26M/M34M cable Specifications Table 21-30 lists specifications of the CBL-V35-HDB26M/M34M cable.
  • Page 298: Pin

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Figure 21-28 CBL-V35-HDB26M/DB25M cable Specifications Table 21-31 lists specifications of the CBL-V35-HDB26M/DB25M cable. Table 21-31 Specifications of the CBL-V35-HDB26M/DB25M cable Parameter Description Name CBL-V35-HDB26M/DB25M Connector HDB26 male connector, or DB25 male connector Type 9.5P+1+B+AL cable...
  • Page 299: Table 21-33 Pin Of The Hdb26 Interface On The Opcom3500E-4V35

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables Defined output for way 1 of Defined output for way 2 of V.35 data V.35 data TD (A) TD (B) SCTE (A) SCTE (B) TCP (A) TCP (A) SCTE (B) RCP (A) PGND TD (B) –...
  • Page 300: Mul-Hdb26 Cables

    The MUL-HDB26 cable is used to connect the HDB26 female connector and other devices to transmit MULTI services. Table 21-34 lists relationships between the MUL-HDB26 cable and the card on the iTN2100. Table 21-34 Relationships between the MUL-HDB26 cable and the card on the iTN2100...
  • Page 301: Cbl-Mul-Hdb26M/Nc

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.13.2 CBL-MUL-HDB26M/NC Appearance Figure 21-29 shows the CBL-MUL-HDB26M/NC cable. Figure 21-29 CBL-MUL-HDB26M/NC cable Specifications Table 21-35 lists specifications of the CBL-MUL-HDB26M/NC cable. Table 21-35 Specifications of the CBL-MUL-HDB26M/NC cable Parameter Description Name CBL-MUL-HDB26M/NC...
  • Page 302 Raisecom iTN2100 (P100R002) Hardware Description 21 Cables HDB26F HDB26M Line color Pair color GND6 Grey/White White/Grey TXD-5 Grey/Red RXD-5 Red/Grey TXD-4 Brown/Red RXD-4 Red/Brown TXD-3 Orange/Red RXD-3 Red/Orange TXD-2 Green/Red RXD-2 Red/Green TXD-1 Blue/Red RXD-1 Red/Blue GND5 Grey/Black Black Black/Grey...
  • Page 303: Cbl-Mul-Hdb26M(40)/Nc

    Raisecom iTN2100 (P100R002) Hardware Description 21 Cables 21.13.3 CBL-MUL-HDB26M(40)/NC Appearance Figure 21-30 shows the CBL-MUL-HDB26M(40)/NC cable. Figure 21-30 CBL-MUL-HDB26M(40)/NC cable Specifications Table 21-37 lists specifications of the CBL-MUL-HDB26M(40)/NC cable. Table 21-37 Specifications of the CBL-MUL-HDB26M(40)/NC cable Parameter Description Name CBL-MUL-HDB26M(40)/NC...
  • Page 304 Raisecom iTN2100 (P100R002) Hardware Description 21 Cables HDB26M HDB26M Line color Secondary Master color color CH-03A White background and Green green ring Green background and CH-03B white ring CH-04A White background and Brown brown ring CH-04B Brown background and white ring...
  • Page 305 Raisecom iTN2100 (P100R002) Hardware Description 21 Cables HDB26M HDB26M Line color Secondary Master color color CH-12A Black background and Orange orange ring Orange background CH-12B and black ring CH-13A Black background and Green green ring CH-13B Green background and black ring...
  • Page 306: Appendix

    Power consumption of optical/electrical modules  Terms  Abbreviations 22.1 Power consumption of optical/electrical modules 22.1.1 SFP modules Table 22-1 lists the power consumption of Raisecom SFP modules. Table 22-1 Power consumption of SFP modules Model Max. power consumption (W) CSFP-Gb/L/xx-D-R 1.32 CSFP-48/L/xx-D-R...
  • Page 307: Terms

    Raisecom iTN2100 (P100R002) Hardware Description 22 Appendix Table 22-2 Power consumption of Raisecom XFP modules Type Model Max. power consumption (W) CXFP All modules DXFP All modules UXFP UXFP-192/M UXFP-192/S1 UXFP-192/S2 UXFP-192/S3 22.2 Terms 1+1 protection The sender transmits services in both the primary channel and the slave channel, and the receiver receives services from the primary channel.
  • Page 308 Raisecom iTN2100 (P100R002) Hardware Description 22 Appendix Failover Provide a port association solution, extending link backup range. Transport fault of upper layer device quickly to downstream device by monitoring upstream link and synchronize downstream link, then trigger switching between master and standby device and avoid traffic loss.
  • Page 309: Abbreviations

    Raisecom iTN2100 (P100R002) Hardware Description 22 Appendix Asynchronous transmission mode, no handshaking signal, point-to- RS232 point communication with other station RS232 or RS422, transparent transmission, up to 19.2 Kbit/s. Single-mode fiber Optical signals of a single mode can be transmitted in the fiber.
  • Page 310 Raisecom iTN2100 (P100R002) Hardware Description 22 Appendix Electromagnetic Compatibility Ethernet Over Plesynchronous Digital Hierarchy Ethernet Over Synchronous Digital Hierarchy Fast Ethernet G.SHDSL G.Single-pair High Speed Digital Subscriber Line Gigabit Ethernet Generic Framing Procedure HDB3 High Density Bipolar of Order 3 Code...
  • Page 311 Raisecom iTN2100 (P100R002) Hardware Description 22 Appendix Plesiochronous Digital Hierarchy QinQ 802.1Q in 802.1Q Quality of Service Relative Humidity RMON Remote Network Monitoring Synchronous Digital Hierarchy Small Form-factor Pluggable Service Level Agreement SNMP Simple Network Management Protocol STM-N Synchronous Transport Module Level-N...
  • Page 312 Address Building2, No.28, Shangdi 6thStreet, Haidian District, Beijing, P.R.China. Postal code: 100085 Tel: 8610-82883305 Fax: 8610-82883056 http://www.raisecom.com Email: export@raisecom.com...