21.6 Grounding cables

21.6.1 Introduction

The grounding cable is used to ground the iTN2100 chassis.

21.6.2 Appearance

The grounding cable of the iTN2100 consists of OT terminals and co-axial cable, as listed in
Figure 21-12.

Figure 21-12 Grounding cable

21.6.3 Specifications

Table 21-9 lists specifications of the grounding cable of the iTN2100.

Table 21-9 Specifications of the grounding cable

Model (recommended)
Standard
Conducting wire
Stripped end
Insulation sleeve
Welding technology
Wilding standard
Error in length of
conducting wire
Parameter
PIL-grounding cable-Φ4-D
Comply with the UL standard and meet RoHS requirements.
Yellow-green multi-strand copper-core conducting wire (1.25
mm
Electronic wire used UL1007 or UL1005
10 mm length and plated with tin
3.5/1.75 black heat-shrink tubing. It is a 20 mm plastic tube
which shrinks when heated.
The conducting and OT terminals adopts solderless crimped
connection.
GB/T18290.2-2000
± 5 mm
Raisecom Technology Co., Ltd.