Alarms; Table 7-12 Alarms Of The Opcom3500E-4Stm1-S - Raisecom iTN2100 Hardware Description

Table of Contents

Advertisement

Raisecom
iTN2100 (P100R002) Hardware Description
SYS
LOF (1–4)
LOS (1–4)

7.2.5 Alarms

Table 7-12 lists alarms of the OPCOM3500E-4STM1-S.

Table 7-12 Alarms of the OPCOM3500E-4STM1-S

RS-LOS
RS-LOF
RS-TIM
AU-AIS
AU-LOP
MS-EXC
LED
Status
Green
Red
Red
Alarm
Attenuation of received signals is over great.
The peer sender fails.
The connector of fiber is dirty or improperly connected.
The local receiver fails.
The TX clock of the peer device fails.
Optical signals do not match.
The local receiving referential clock fails.
The received trace byte of the local device and the sent
trace byte of the peer device are inconsistent.
Services are improperly configured.
The AU-AIS alarm of the VC4 channel is triggered by MS-
AIS, R-LOS, R-LOF alarms.
Services are improperly configured.
The peer device sends AU-AIS alarms.
The TX part of the peer device or the RX part of the local
device fails.
The RX part of the peer device fails.
Services are improperly configured on the peer device.
Bit Error Rate (BER) of the local device is over great.
BER in the multiplexing section is over high.
Optical signals are improperly transmitted.
The performance of the local card is bad.
Raisecom Technology Co., Ltd.
Description
System status LED
Green: the system is working improperly.
Off: the system is working improperly.
Blinking green: the system is working properly.
LOF alarm LED
Red: input Loss of Frame (LOF) alarms are generated on
related optical interfaces.
Off: no input LOF alarms are generated on related
optical interfaces.
LOS alarm LED
Red: input Loss of Signal (LOS) alarms are generated on
related optical interfaces.
Off: no input LOS alarms are generated on related
optical interfaces.
Cause
7 SDH tributary cards
Level
Critical
Critical
Critical
Minor
Critical
Major
43