  • Page 2 Website: http://www.raisecom.com Tel: 8610-82883305 Fax: 8610-82883056 Email: export@raisecom.com Address: Raisecom Building, No. 11, East Area, No. 10 Block, East Xibeiwang Road, Haidian District, Beijing, P.R.China Postal code: 100094 ----------------------------------------------------------------------------------------------------------------------------------------- Notice Copyright © 2017 Raisecom All rights reserved.
  • Page 3: Symbol Conventions

    Objectives This guide describes the scenarios, methods, and safety precautions for installing the ISCOM5508-GP, which effectively guides you in installing the ISCOM5508-GP. Read the security chapter before installing the hardware to prevent device damage or bodily injury caused by improper installation.
  • Page 4: General Conventions

    Raisecom ISCOM5508-GP (A) Installation Guide Preface General conventions Convention Description Times New Roman Normal paragraphs are in Times New Roman. Arial Paragraphs in Warning, Caution, Notes, and Tip are in Arial. Boldface Buttons and navigation path are in Boldface. Italic Book titles are in italics.
  • Page 5: Keyboard Operation

    Raisecom ISCOM5508-GP (A) Installation Guide Preface Keyboard operation Format Description Press the key. For example, press Enter and press Tab. Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl + C means the two keys should be pressed concurrently.
  • Page 6: Table Of Contents

    Raisecom ISCOM5508-GP (A) Installation Guide Contents Contents 1 Safety instruction .......................... 1 1.1 Safety statement ............................... 1 1.2 Safety symbols ..............................1 1.3 Electrical safety ..............................2 1.3.1 High voltage safety ..........................2 1.3.2 Power cable safety ..........................2 1.3.3 Thunder-and-lightning safety ........................3 1.3.4 Electrostatic safety ..........................
  • Page 7 Raisecom ISCOM5508-GP (A) Installation Guide Contents 3.2 Check before installation ..........................14 3.3 Installing chassis ............................15 3.3.1 Introduction ............................15 3.3.2 Installing chassis in cabinet ........................15 3.3.3 Installing chassis on workbench......................18 3.3.4 Connecting ground cable ........................19 4 Installing components ........................
  • Page 8 Raisecom ISCOM5508-GP (A) Installation Guide Contents 8.3.1 Introduction of ribbon ........................... 47 8.3.2 The usage of ribbon ..........................47 Raisecom Technology Co., Ltd.
  • Page 9 Raisecom ISCOM5508-GP (A) Installation Guide Figures Figures Figure 2-1 Unpacking chassis ..........................10 Figure 2-2 Unpacking components ........................11 Figure 3-1 Installation process ..........................14 Figure 3-2 Installing floating nuts ........................16 Figure 3-3 Installing standard brackets on the left side of the chassis ..............16 Figure 3-4 Installing standard brackets on the right side of the chassis ...............
  • Page 10 Raisecom ISCOM5508-GP (A) Installation Guide Figures Figure 5-6 Connecting optical connectors ......................30 Figure 5-7 Connecting configuration cable ......................30 Figure 8-1 Tail fiber binding tape ......................... 36 Figure 8-2 The clipping of binding tape ....................... 37 Figure 8-3 The clipping of tail fiber binding tape ....................37 Figure 8-4 Tail fiber binding tape .........................
  • Page 11 Raisecom ISCOM5508-GP (A) Installation Guide Tables Tables Table 1-1 Types and meanings for safety symbols ....................2 Table 2-1 Tools and instruments for preparation ....................6 Table 2-2 Working environment parameters ......................8 Table 2-3 Power conditions ............................ 9 Table 6-1 Checklist of the machine room and surrounding environment ............. 31 Table 6-2 Checklist of cabinet or workbench .......................
  • Page 12: Safety Instruction

    Only qualified and authorized service personnel should carry out adjustment and installation. The device installation should comply with local security specifications strictly. Safety matters mentioned in the manual is supplementary. Raisecom shall not be liable for any accident caused by violating general safety operation requirements and the safety standard of design, production and usage.
  • Page 13: Electrical Safety

    Raisecom ISCOM5508-GP (A) Installation Guide 1 Safety instruction Table 1-1 Types and meanings for safety symbols Symbols Meanings Danger of high voltage! Electrostatic symbol, indicating that the equipment is sensitive to static electricity. E S D Earth connecting symbol, indicating that the equipment should be connected to the earth.
  • Page 14: Thunder-And-Lightning Safety

    Raisecom ISCOM5508-GP (A) Installation Guide 1 Safety instruction  Turn off or disconnect the power before installing and removing power cord.  Make sure that the power cord label displays correctly before connection.  Only power cords meeting the specifications are allowed.
  • Page 15: Laser Safety

    Raisecom ISCOM5508-GP (A) Installation Guide 1 Safety instruction Before entering the electromagnetic radiation over-standard zone, you should confirm the position of the zone and turn off the transmitter. High strength radio frequency signal is harmful to human body. 1.4.2 Laser safety Laser transceiver is used for optical transmission systems and related test.
  • Page 16: Carrying Chassis

    1.6.3 Replacing components Card replacement or equipment modification may lead to additional risk. Do not replace cards or modify equipment without authorization. To ensure safety, if you have any questions, contact Raisecom office or technical support. Raisecom Technology Co., Ltd.
  • Page 17: Preparing For Installation

    Raisecom ISCOM5508-GP (A) Installation Guide 2 Preparing for installation Preparing for installation This chapter describes equipment installation preparation, including the following matters:  Preparing tools  Checking installation conditions  Checking boxes 2.1 Preparing tools and instruments Prepare tools and instruments before installing as shown in Table 2-1.
  • Page 18 Raisecom ISCOM5508-GP (A) Installation Guide 2 Preparing for installation Name Picture Name Picture Vice Crimper: Wire Stripper: used to crimping used to divest the connector of insulating layer telephone line for small section and cable crystal communication head cable Adjustable...
  • Page 19: Checking Installation Conditions

    The ISCOM5508-GP is not delivered with instruments and tools, which should be prepared by yourself. 2.2 Checking installation conditions 2.2.1 Installation environment The equipment installation should meet the working environment shown in Table 2-2.
  • Page 20: Power Conditions

    VAC to 240 VAC. Rated voltage: -48 VDC with voltage fluctuation ranging from -38 VDC DC Power to -72 VDC Alternative A backup UPS is preferred to keep the ISCOM5508-GP running in case power of power failure. Power > 63 W consumption 2.2.3 Grounding conditions...
  • Page 21: Checking Box Before Unpacking

    According to the inspection, take appropriate processing methods:  Stop unpacking the box if there is severe damage, dampening of outer packing box, box inversion, wrong goods or deficiency of goods. Give feedback to the local Raisecom office once finding out reasons. ...
  • Page 22: Upacking Components

     Stop unpacking the box immediately if the components are found rusted or dampened during the unpacking process. Give feedback to the local Raisecom office after finding out reasons together with Raisecom engineers. Pay attention to the following items in the process of unpacking components: ...
  • Page 23: Acceptance Inspection

    Check the devices type and quantity according to the Packing List and sign to accept them face to face.  In case of wrong goods or deficiency of goods, contact Raisecom engineers. Raisecom engineers will contact the relevant commissioner to replace goods or replenish goods for you.
  • Page 24: Installing Chassis

    Raisecom ISCOM5508-GP (A) Installation Guide 3 Installing chassis Installing chassis This chapter introduces device installation process and precautions.  Installation process  Check before installation  Installing chassis 3.1 Installation process Figure 3-1 shows the installation process. Raisecom Technology Co., Ltd.
  • Page 25: Check Before Installation

    Raisecom ISCOM5508-GP (A) Installation Guide 3 Installing chassis Figure 3-1 Installation process The ISCOM5508-GP should be installed indoor for fixed use. 3.2 Check before installation Confirm the following items before installing the device:  You have read the contents in section 2 Preparing for installation.
  • Page 26: Installing Chassis

    Wear a properly-grounded ESD wrist strap when installing the chassis and components to prevent damage caused by static electricity. If you plan to install the ISCOM5508-GP device in cabinet, refer to section 2.2 Checking installation conditions to choose a cabinet which meets the following requirements:...
  • Page 27: Figure 3-2 Installing Floating Nuts

    The cabinet is strong enough to support the weight of the ISCOM5508-GP device and its components.  The size of the cabinet is fit for the ISCOM5508-GP device; there must be some room around the ISCOM5508-GP device for heat dissipation. ...
  • Page 28: Figure 3-4 Installing Standard Brackets On The Right Side Of The Chassis

    Raisecom ISCOM5508-GP (A) Installation Guide 3 Installing chassis Figure 3-4 Installing standard brackets on the right side of the chassis Step 3 Uplift the chassis with your hands and move it to the front of the cabinet slowly and stably.
  • Page 29: Installing Chassis On Workbench

    We recommend installing the device in a standard cabinet or an open rack. If you wish to install the ISCOM5508-GP device on a workbench, make sure the workbench meet the following conditions: ...
  • Page 30: Connecting Ground Cable

    Raisecom ISCOM5508-GP (A) Installation Guide 3 Installing chassis Figure 3-7 Sticking rubber feet Step 3 Put the chassis upright and lift the chassis up with your hands. Step 4 Put the chassis on the workbench slowly and steadily, as shown in Figure 3-8.
  • Page 31: Figure 3-10 Location Of Ground Terminals

    The ground cable cannot be longer than 30m and should be as short as possible; otherwise, a ground bar should be used. The ground terminal is located on the back of the ISCOM5508-GP, as shown in Figure 3-10. Figure 3-10 Location of ground terminals You have to ensure that the cabinet or workbench is well grounded when installing a chassis.
  • Page 32: Figure 3-12 Grounding Chassis

    If the resistance is smaller than 1 Ω, it indicates that the ground cable is properly connected. Connect the ground cable of the ISCOM5508-GP to the ground in the machine room. Do not connect it to a water pipe or lightning rod.
  • Page 33: Installing Components

    Raisecom ISCOM5508-GP (A) Installation Guide 4 Installing components Installing components This chapter introduces the card installation process and precautions.  Anti-static preparation  Installing components  Removing components 4.1 Anti-static preparation Read 1.3.4 Electrostatic safety carefully and wear an ESD wrist strap before installing cards.
  • Page 34: Installing Components

    Insert the other end of the ESD wrist strap to the ESD jack in the machine room. The components of the ISCOM5508-GP contain the MCC, subcards, and modules. Install the components according to the following steps: Step 1 Check the components connectors and the pins on the backplane.
  • Page 35: Removing Components

    Raisecom ISCOM5508-GP (A) Installation Guide 4 Installing components When inserting components, ensure that the plugs of components are aligned with the socket on the chassis backplane and both sides of the components are on the guide rail. Do not forcedly insert the components when the process is hindered.
  • Page 36: Figure 4-5 Loosening Captive Screws

    Raisecom ISCOM5508-GP (A) Installation Guide 4 Installing components Figure 4-5 Loosening captive screws Step 4 Pinch the ejector levers on both sides of the card and pull the card outward. The card will be off from the backplane (about 1cm), as shown in Figure 4-6.
  • Page 37: Connecting Cables

    Raisecom ISCOM5508-GP (A) Installation Guide 5 Connecting cables Connecting cables This chapter introduces the cable connection operation processes and precautions.  Connecting DC power cable  Connecting AC power cables  Connecting Ethernet cables  Connecting optical fibers  Connecting configuration cables 5.1 Connecting DC power cable...
  • Page 38: Connecting Ac Power Cables

    Raisecom ISCOM5508-GP (A) Installation Guide 5 Connecting cables Step 3 Tighten the captive screws on the DC power connector, as shown in Figure 5-2. Figure 5-2 Tightening captive screws on DC power connector Step 4 Connect the other end of the power cable with power sourcing equipment in machine room.
  • Page 39: Connecting Ethernet Cables

    5.3 Connecting Ethernet cables Ethernet cable is used to connect the ISCOM5508-GP device with other devices, providing 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s transmission rate. According to the wiring corresponding to the two ends of the RJ45 connector, the network cable can be divided into straight-through cable and cross-over cable: ...
  • Page 40: Connecting Optical Fibers

    Raisecom ISCOM5508-GP (A) Installation Guide 5 Connecting cables 5.4 Connecting optical fibers Do not look directly at the fiber optic connector connected with laser. Otherwise, it may injure the eyes. Pay attention to the following matters when connecting optical fibers: ...
  • Page 41: Connecting Configuration Cables

    Raisecom ISCOM5508-GP (A) Installation Guide 5 Connecting cables Figure 5-6 Connecting optical connectors 5.5 Connecting configuration cables The configuration cable (also known as Console cable) is a 4-core shielded cable used to connect the Console interface to RS-232 serial port on a computer and transmit configuration data signals of the device.
  • Page 42: Checking Hardware Installation

    Raisecom ISCOM5508-GP (A) Installation Guide 6 Checking hardware installation Checking hardware installation This chapter introduces the check items after installation.  Checking machine room and the surrounding environment  Checking cabinet or workbench  Checking chassis and cards  Checking cables 6.1 Checking machine room and the surrounding...
  • Page 43: Checking Chassis And Cards

    Raisecom ISCOM5508-GP (A) Installation Guide 6 Checking hardware installation Table 6-2 Checklist of cabinet or workbench Item Requirement  Structure attachments are installed correctly and reliably, switches of Cabinet doors and locks work normally.  All other connection bolts are installed correctly and reliably, the flat washers and spring washers are installed in a correct order.
  • Page 44: Table 6-4 Checklist Of Cables

    Raisecom ISCOM5508-GP (A) Installation Guide 6 Checking hardware installation Table 6-4 Checklist of cables Item Requirement  The connection is correct and reliable. Power cables, ground cables, and Power signal cables are laid separately in the cabinet; the distance among power...
  • Page 45: Power-On Test

    Use a multi-meter to test the AC power and ensure that the AC power power voltage is between 100 V to 240 V.  The power capacity must be able to support the ISCOM5508-GP to work at the maximum power consumption. Raisecom Technology Co., Ltd.
  • Page 46: Running Check

    P2. If the difference between P2 and P1 is smaller than 1 dB, it indicates that the fiber is correctly connected. 7.3 Running check Check the following items after powering the ISCOM5508-GP on:  After powering on the device, you can hear the sound of fan rotation and there is air discharge from ventilation holes.
  • Page 47: Installation Reference

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Installation reference This chapter introduces the installation reference of the ISCOM5508-GP device.  Tail fiber binding tape  Cable label specifications  Introduction and usage of ribbon 8.1 Tail fiber binding tape 8.1.1 The structure of tail fiber binding tape...
  • Page 48: Use Of Tail Fiber Binding Tape

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Figure 8-2 The clipping of binding tape Step 2 Roll the binding tape to route it through the guide slot of the cutter, as shown in Figure 8-3. Figure 8-3 The clipping of tail fiber binding tape Step 3 Cut off the binding tape in the suitable length.
  • Page 49: Precautions

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Figure 8-4 Tail fiber binding tape Step 5 The finished effect is shown in Figure 8-5. Figure 8-5 Finished effect 8.1.4 Precautions Comply with the following requirements when binding tail fibers. ...
  • Page 50: Cable Label Specifications

     Power cable label: used to stick DC power cable and AC power cable. 8.2.1 Overview of label Raisecom provides the following cable labels, as shown in Figure 8-6. Figure 8-6 Cable label The label material has the following characteristics: ...
  • Page 51: Method To Stick Labels

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference  To make the handwriting identifiable and elegant, you should write the words according to the standard font template (Times New Roman) as much as possible. Table 8-1 shows the standard font template.
  • Page 52: Project Label Of Network Cable

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Figure 8-9 Label sticking process 8.2.4 Project label of network cable The project label of network cable applies to the Ethernet interface cables of a cabinet, chassis, and card. The cable label contents of the cabinet, chassis, and card are shown in Table 8-2.
  • Page 53: Project Label Of Optical Fiber

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference The meaning of the cable label:  A01-03-02-01: indicates the local device connected by the network cable, namely, Ethernet port 1, Slot 2, Frame 3, in the cabinet in Row A Column 1.
  • Page 54: Figure 8-11 Fiber Label Between Devices

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Lable content Meaning Example Y-Board/Slot No. Ordered from left right, top bottom, numbered from 1 For example: 01 indicates Card 1. Z: Optical interface No. Ordered from top bottom, left right, with two numbers For example: 01 indicates the first optical interface.
  • Page 55: Project Label Of Dc Power Cable

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Lable content Meaning Example ODF-MN-X-Y-R/T MN: ODF line No. and M: devices from front to end in the machine room are column No. called a row of devices, numbered A–Z. N: devices from left to right in the machine room are called a column of devices, numbered 01–99.
  • Page 56: Figure 8-13 Dc Power Cable Label

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Label content Meaning No. of the "-48V" terminal of the distribution equipment (it can be omitted if there is MN(XY)–B-PGND no row/column No. or it is of no need to identify the row/column No. of terminal.). It is of no need to distinguish the row/column No for BGND and PGND.
  • Page 57: Project Label Of Ac Power Cable

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference 8.2.7 Project label of AC power cable Project label of AC power cable is used in AC power cable in the cabinet for AC power supply, including 220V, BGND, PGND, etc. It is usually pasted on both ends of the AC power cable.
  • Page 58: Introduction And Usage Of Ribbon

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference 8.3 Introduction and usage of ribbon 8.3.1 Introduction of ribbon Ribbon is a plastic belt to bind things, which has non-retreat function in design. The ribbon has four features which are fast lashing, good insulation, self-locking and easy to use and is widely used in cable bundle and consolidation.
  • Page 59: Figure 8-17 Binding Effect

    Raisecom ISCOM5508-GP (A) Installation Guide 8 Installation reference Step 5 Cut the excessive part of the ribbon with scissors, as shown in Figure 8-17. Figure 8-17 Binding effect Bind cables according to the following requirements:  The cable binding should be neat, clear and artistic. Generally, cables are grouped by category, tied with string clip, and then taken for upward routing or downward routing according to the routing at the two sides of the cabinet.
  • Page 60 Address Building 2, No. 28, Shangdi 6th Street, Haidian District, Beijing, P.R.China. Postal code: 100085 Tel: +86-10-82883305 Fax: 8610-82883056 http://www.raisecom.com Email: export@raisecom.com...

This manual is also suitable for:

Iscom5508-gpa