Table of Contents

Advertisement

Quick Links

www.raisecom.com
RC1201-2GE16E1T1
Product Description
(P100R001_01)

Advertisement

Table of Contents
loading

Summary of Contents for Raisecom RC1201-2GE16E1T1

  • Page 1 RC1201-2GE16E1T1 Product Description (P100R001_01)
  • Page 2 Raisecom Technology Co., Ltd. provides customers with comprehensive technical support and services. For any assistance, please contact our local office or company headquarters. Website: http://www.raisecom.com Tel: 8610-82883305 Fax: 8610-82883056 Email: export@raisecom.com Address: Building 2, No. 28, Shangdi 6th Street, Haidian District, Beijing, P.R.China...
  • Page 3 RC1201-2GE16E1T1 Product Description 1 Preface Preface Objectives This guide describes the RC1201-2GE16E1T1 in terms of product orientation, features, system structure, services, functions, OAM, reliability, technical specifications, and installation. The appendix lists all terms, acronyms, and abbreviations involved in this document.
  • Page 4 Raisecom RC1201-2GE16E1T1 Product Description 1 Preface General conventions Convention Description Times New Roman Normal paragraphs are in Times New Roman. Arial Paragraphs in Warning, Caution, Notes, and Tip are in Arial. Names of files, directories, folders, and users are in boldface.
  • Page 5 Raisecom RC1201-2GE16E1T1 Product Description 1 Preface Keyboard operation Format Description Press the key. For example, press Enter and press Tab. Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+C means the two keys should be pressed concurrently. Key 1, Key 2 Press the keys in turn.
  • Page 6: Table Of Contents

    Raisecom RC1201-2GE16E1T1 Product Description 1 Contents Contents 1 Overview ............................1 1.1 Introduction ..............................1 1.2 Networking applications ..........................2 1.2.1 Key customer private line access ......................2 1.2.2 Multiplexing of multiple ways of voice and Ethernet services ............... 2 1.3 Features ................................
  • Page 7 Raisecom RC1201-2GE16E1T1 Product Description 1 Contents 3.4.2 VLAN ..............................31 3.4.3 QinQ..............................32 3.4.4 VLAN mapping............................. 33 3.4.5 Loopback detection ..........................34 3.5 QoS................................. 34 3.5.1 Priority trust ............................34 3.5.2 Priority mapping ........................... 34 3.5.3 Traffic classification ..........................35 3.5.4 Traffic policy ............................
  • Page 8 Raisecom RC1201-2GE16E1T1 Product Description 1 Contents 6.2.3 Electrical safety ............................. 59 6.2.4 Radiation safety ............................ 60 6.2.5 Mechanical safety ..........................61 6.3 Preparing for installation ..........................61 6.3.1 Preparing tools ............................62 6.3.2 Changing installation condition ......................64 6.3.3 Checking boxes ............................. 65 6.4 Installation procedure .............................
  • Page 9 Figures Figure 1-1 Networking with RC1201-2GE16E1T1 for key customer private line access ........2 Figure 1-2 Networking for multiplexing of multiple voice and Ethernet services with the RC1201-2GE16E1T1 3 Figure 2-1 Front panel of the RC1201-2GE16E1T1 ....................8 Figure 2-2 Front panel of the main control card on the RC1201-2GE16E1T1 ............9 Figure 2-3 Front panel of the Ethernet subcard on the RC1201-2GE16E1T1 ............
  • Page 10 Figure 6-5 Installing chassis to the workbench ....................71 Figure 6-6 Grounding cable ..........................71 Figure 6-7 Grounding terminal on the rear panel of the RC1201-2GE16E1T1 ........... 72 Figure 6-8 Connecting the chassis grounding cable ..................... 72 Figure 6-9 Inserting the DC power cable ......................73 Figure 6-10 Tightening the spring screws on DC power outlet ................
  • Page 11 RC1201-2GE16E1T1 Product Description 1 Tables Tables Table 1-1 All models of the RC1201-2GE16E1T1 available for purchase ............5 Table 1-2 Auxiliary parts for the RC1201-2GE16E1T1 ..................6 Table 2-1 Service interfaces on the RC1201-2GE16E1T1 ................... 10 Table 2-2 Management and auxiliary interfaces on the RC1201-2GE16E1T1 ............ 10 Table 2-3 Parameters of the 1000Base-X SFP optical interface ................
  • Page 12 Table 5-4 Parameters of the 1000Base-X SFP ..................... 49 Table 5-5 Reliability specifications of the RC1201-2GE16E1T1 ................ 49 Table 5-6 atmosphere requirements for the RC1201-2GE16E1T1 during storage ..........50 Table 5-7 Mechanical active substance requirements during storage ..............51 Table 5-8 Chemical active substance requirements during storage ..............52 Table 5-9 Atmosphere requirements for the RC1201-2GE16E1T1 during transport ...........
  • Page 13: Overview

    Basic functions of the RC1201-2GE16E1T1 are to emulate TDM services, carry emulated service packets through the PSN, and implement transparent transmission of TDM services on the PSN. As a local device, it can cooperate with other TDMoP devices of Raisecom, such as the RC1201-4FE4E1T1.
  • Page 14: Networking Applications

    1 Overview 1.2 Networking applications Oriented for the access aggregation layer of the network, the RC1201-2GE16E1T1 is of modular design, small size, and high integration. In NGN construction, it expands the PSN to the access end by providing reliable E1/T1 service access, high bandwidth Ethernet private line access, and complete Operation, Administration, and Maintenance (OAM) functions.
  • Page 15: Features

    Figure 1-2 Networking for multiplexing of multiple voice and Ethernet services with the RC1201- 2GE16E1T1 1.3 Features The RC1201-2GE16E1T1 supports multiple types of service and provides abundant features to ensure service transmission of high quality and efficiency. 1.3.1 Service types The RC1201-2GE16E1T1 supports the following types of service: ...
  • Page 16: Interface Types

    Flow control based on interface or Virtual Local Area Network (VLAN) 1.4 Delivery models Delivery models refer to the models and configuration list available for the customer to purchase. 1.4.1 Main delivery models Table 1-1 lists main delivery models of the RC1201-2GE16E1T1 available for purchase. Raisecom Technology Co., Ltd.
  • Page 17: Table 1-1 All Models Of The Rc1201-2Ge16E1T1 Available For Purchase

    Raisecom RC1201-2GE16E1T1 Product Description 1 Overview Table 1-1 All models of the RC1201-2GE16E1T1 available for purchase Model Description Aggregation TDMoP device  Support 16 ways E1/T1 services for downlink service interface (8 RJ45 interfaces. Each RJ45 interface outputs 2 ways of E1/T1 services).
  • Page 18: Auxiliary Parts

    Support hybrid backup with a AC power module and a +24 V DC power module. 1.4.2 Auxiliary parts Table 1-2 lists auxiliary parts for the RC1201-2GE16E1T1. You can purchase them if needed. Table 1-2 Auxiliary parts for the RC1201-2GE16E1T1 Card...
  • Page 19 Raisecom RC1201-2GE16E1T1 Product Description 1 Overview Card Description AC power module  Provide 220 V AC power RPA0601-SI-220S12  Support dual power backup.  Support overvoltage and undervoltage detection.  Support hot swapping. -48 V DC power module  Provide -48 V DC power.
  • Page 20: System Structure

    Power modules  A fan module 2.1.1 Outlook The RC1201-2GE16E1T1, in box structure, provides two slots for Ethernet subcards on the backplane, which can flexibly meet the customer's requirements. Front panel Figure 2-1 shows the front panel of the RC1201-2GE16E1T1.
  • Page 21: Figure 2-2 Front Panel Of The Main Control Card On The Rc1201-2Ge16E1T1

    8 RJ45 interfaces and LEDs (8 RJ45 interfaces can transmit 16 ways of E1/T1 services) Figure 2-2 Front panel of the main control card on the RC1201-2GE16E1T1 Figure 2-3 shows the front panel of the Ethernet subcard on the RC1201-2GE16E1T1, on which there are four 10/100/1000 Mbit/s Ethernet electrical interfaces and LEDs.
  • Page 22: Interface Types

    2 System structure Figure 2-4 Rear panel of the RC1201-2GE16E1T1 2.1.2 Interface types The RC1201-2GE16E1T1 interfaces include two types: the SNMP interface and the Console interface. Service interfaces The RC1201-2GE16E1T1 transmits services with multiple types of service interface, as listed in Table 2-1.
  • Page 23: Interface Parameters

    Raisecom RC1201-2GE16E1T1 Product Description 2 System structure Name Type Description Quantity SNMP RJ45 Network management interface It is connected to the Network Management System (NMS). 2.1.3 Interface parameters Optical interface parameters Table 2-3 lists parameters of the 1000Base-X SFP optical interface.
  • Page 24: Table 2-5 T1 Interface Parameters

    Raisecom RC1201-2GE16E1T1 Product Description 2 System structure Parameter Description Coding type HDB3 Frame format Unframed, framed, multiframed, with or without CRC-4 Frame structure Complying with ITU-T G.823/G.704 recommendations Clock Complying with ITU-T G.823 recommendations Jitter Complying with ITU-T G.823 recommendations Complying with ITU-T G.703 recommendations, and supporting...
  • Page 25: Table 2-7 Console Interface Parameters

    Raisecom RC1201-2GE16E1T1 Product Description 2 System structure Parameter Description  Supporting 10/100/1000 Mbit/s automatical negotiation Duplex mode  Supporting half/full duplex automatical negotiation  Supporting IEEE 802.3x flow control in full duplex Flow control  Support back pressure flow control in half duplex...
  • Page 26: Leds

    Supporting 10/100 Mbit/s automatical negotiation Line order Host mode, supporting auto MDI/MDIX Compliance standard IEEE 802.3 2.1.4 LEDs The RC1201-2GE16E1T1 has 47 Light-Emitting Diodes LEDs), including:  21 LEDs on the main control card  9 LEDs on the Ethernet subcard ...
  • Page 27: Table 2-10 Leds On Ethernet Subcards

    Raisecom RC1201-2GE16E1T1 Product Description 2 System structure Type Interface Status Description E1/T1 Loss Of Signal (LOS) alarm LED interface  Red: E1/T1 LOS alarms are generated. (1–16)  Off: no E1/T1 LOS alarms are generated. LEDs on Ethernet subcards Table 2-10 lists LEDs on Ethernet subcards.
  • Page 28: Fiber And Cables

    Power alarm LED  Red: the fan module is working improperly with alarms.  Off: the fan module is working properly. 2.1.5 Fiber and cables The fiber and cables used by the RC1201-2GE16E1T1 include:  Fiber  E1 cable ...
  • Page 29: Figure 2-5 Lc/Pc Fiber Connector

    To remove the fiber, press the latch on the connector and pull the fiber out. E1/T1 cables The E1/T1 cable connects the E1/T1 interface on the RC1201-2GE16E1T1 to the TDM interface of other devices, as shown in Figure 2-6. All the 4 pairs of twisted pair transmit E1/T1 signals.
  • Page 30: Figure 2-6 E1/T1 Cable

     SNMP interface and NView NNM system The Ethernet interface on the RC1201-2GE16E1T1 is automatically adaptive to the straight- through cable or the cross connection cable, and thus supports them, as shown in Figure 2-7. Make Ethernet cables according to actual situation on site.
  • Page 31: Table 2-15 100/1000 Mbit/S Straight-Through Network Cable Connection

    Raisecom RC1201-2GE16E1T1 Product Description 2 System structure Table 2-15 lists 100/1000 Mbit/s straight-through network cable connection. Table 2-15 100/1000 Mbit/s straight-through network cable connection Starting from (RJ45) Stopping at (RJ45) Color Remark PIN 1 PIN 1 White/Orange Twisted pair PIN 2...
  • Page 32: Figure 2-8 Configuration Cable

    Pins 8-pin Configurable cables The configuration cable is used to connect the Console interface on the RC1201-2GE16E1T1 to the PC that runs NView NNM software. Use the DB-9 connector and RJ45 connector as configuration cable connectors for the RC1201-2GE16E1T1, as shown in Figure 2-8.
  • Page 33: Figure 2-9 Ac Power Cable

    Power cables The DC power supply cable transmits -48 V or +24 V DC power to terminal block of the DC power, and supplies power to the whole RC1201-2GE16E1T1, as shown in Figure 2-9. Figure 2-9 AC power cable Table 2-20 lists technical specifications of the DC power cable.
  • Page 34: Software Structure

    American standard three-plug connector and receptacle shows as below. Figure 2-11 American standard AC cable 2.2 Software structure As shown in Figure 2-12, based on Raisecom Operating System (ROS), the RC1201- 2GE16E1T1 supports diverse services, functions, and performance indexes required by Metropolitan Access Network (MAN).
  • Page 35 Agents. The NView Network Node Management (NNM), as a new integrated network node management system developed by Raisecom, is based on SNMP and oriented for the access network. The NView NNM implements integrated configuration of Network Elements (NEs), fault detection, topology management, and trap management.
  • Page 37: Service Functions And Features

    How to evolve to the PSN smoothly, namely, to both protect current investment and deploy the PSN, is difficult. As a result, TDMoP is developed accordingly. The RC1201-2GE16E1T1, a TDMoP device based on Pseudo-Wire Emulation Edge to Edge (PWE3), has the following functions and features: ...
  • Page 38: Ethernet Services

    3.1.2 Ethernet services Being flexible, simple, and easy to implement, Ethernet becomes an important technology for networking on a LAN. The RC1201-2GE16E1T1 supports not only TDMoP services but also Ethernet services, thus implementing multiplexing of multiple ways of E1/T1 services and Ethernet services.
  • Page 39: Tdmop

    Raisecom RC1201-2GE16E1T1 Product Description 3 Service functions and features 3.2 TDMoP PWE3 principle PWE3 is a protocol structure to transmit layer 2 emulation services through edge-to-edge tunnel, as shown in Figure 3-1. For details, refer to the RFC3985. CE1 transmits TDM service data to PE1 through AC, and PE1 encapsulates TDM service data to PW messages through corresponding protocols.
  • Page 40: Figure 3-2 Tdmop Circuit Emulation Protocol Stack

    PW emulation messages through a tunnel on the PSN. Figure 3-2 shows the location of PW in TDMoP circuit emulation protocol stack. By distributing and exchanging PW labels, the RC1201-2GE16E1T1 forwards TDMoP circuit emulation services between different PSN nodes. The PW label also identifies different PW emulation packet flow in a tunnel, so it cannot be duplicated in the same tunnel.
  • Page 41: Tdmop Clock Synchronization

    Jitter buffer on the destination can reduce the impact from change of frame delay. It buffers early or late frames. Its capacity should be set properly. The RC1201-2GE16E1T1 supports configuring capacity of the jitter buffer through commands. 3.3 TDMoP clock synchronization The key to TDMoP is clock synchronization.
  • Page 42: Ethernet Features

    MAC address table, which is the basis for fast forwarding. The MAC address table is saved in the cache of the RC1201-2GE16E1T1. The cache capacity determines how many MAC addresses can be saved.
  • Page 43: Vlan

    Aging time for MAC addresses The MAC address table of the RC1201-2GE16E1T1 is limited by capacity. To fully use it to the maximum, the RC1201-2GE16E1T1 updates it through aging mechanism. Namely, it is enabled with an aging timer when a MAC address entry is created. If no packets are received from a MAC address that is already in the MAC address table, the MAC address entry will be automatically deleted.
  • Page 44: Qinq

    Raisecom RC1201-2GE16E1T1 Product Description 3 Service functions and features Table 3-1 Ports modes and packet forwarding modes Port Forwarding modes for ingress packet Forwarding modes for egress mode packet Untag packet Tag packet  If the VLAN ID for a...
  • Page 45: Vlan Mapping

    2GE16E1T1 will match the private VLAN Tag according to configured VLAN mapping rules. If success, the private VLAN Tag is replaces according to configured VLAN mapping rules. The RC1201-2GE16E1T1 supports 1:1 VLAN mapping only; that is, it replaces VLAN Tag of packets from a specified VLAN with new VLAN Tag.
  • Page 46: Loopback Detection

     The RC1201-2GE16E1T1 checks the source MAC field of the received packet. If the MAC address of the RC1201-2GE16E1T1 is saved in the source MAC field, it is believed that a loopback is detected on some port of the RC1201-2GE16E1T1.
  • Page 47: Traffic Classification

    RC1201-2GE16E1T1 Product Description 3 Service functions and features Mapping the outer priority carried by packets to the local priority of the RC1201-2GE16E1T1 is the prerequisite. For packets from upstream devices, the RC1201-2GE16E1T1 can map priority carried by packets to different local priorities of the RC1201-2GE16E1T1. Then it schedules different queues according to local priorities.
  • Page 48: Figure 3-6 Traffic Classification Process

    Raisecom RC1201-2GE16E1T1 Product Description 3 Service functions and features Figure 3-6 Traffic classification process DSCP priority Structure for IP packet header is displayed in Figure 3-7. An 8-bit ToS field is contained in this packet. For the RFC1349, the first 3 bits of the ToS field representing the ToS priority.
  • Page 49: Traffic Policy

    Therefore, network resources and Carrier's benefits are protected. The RC1201-2GE16E1T1 supports limiting rate on the ingress port based on traffic policy. Redirection Redirection refers a packet is not forwarded according to the mapping relationship between the original destination address and the port.
  • Page 50: Queue Scheduling

    Raisecom RC1201-2GE16E1T1 Product Description 3 Service functions and features The RC1201-2GE16E1T1 supports remarking following priority fields for packets:  ToS priority for IP packets  DSCP priority for IP packets  CoS priority for VLAN packets 3.5.5 Queue scheduling You need to perform the queue scheduling when delay-sensitive services need better QoS services than non-delay sensitive and when the network is congested once in a while.
  • Page 51: Rate Limiting Based On Ports And Vlans

    Figure 3-13 DRR scheduling 3.5.6 Rate limiting based on ports and VLANs In addition to supporting traffic policy-based rate limiting, the RC1201-2GE16E1T1 supports port-based and VLAN ID-based rate limiting. Similar with the processing method for rate limiting based on traffic policy, the RC1201-2GE16E1T1 discards the exceeding traffic.
  • Page 52: Storm Control

    The RC1201-2GE16E1T1 support manual link aggregation. The process of aggregating multiple physical ports to a logical interface does not require any protocol. The consistency of interface parameters is ensured manually.
  • Page 53: Operation, Management, And Maintenance

    Management through Console interface Through the Console interface, you can use a terminal or Personal Computer (PC) that runs emulation program to manage and configure the RC1201-2GE16E1T1. Even if the network fails, you can use the Console for management and configuration instead.
  • Page 54: Maintenance And Test Tools

    RC1201-2GE16E1T1 Product Description 4 Operation, management, and maintenance 4.1.2 Maintenance and test tools The RC1201-2GE16E1T1 supports diagnosing and debugging software and hardware bugs with the following tools. PING Packet Internet Grope (PING), a most widely used command for diagnosing and debugging, is to test whether two devices are connected.
  • Page 55: Nview Nnm System

    4.2 NView NNM system 4.2.1 Introduction to functions "Comprehensive Access, Overall Network Management" is a vision that Raisecom has been in pursuit of. The NView NNM system is developed to provide overall and efficient OAM requirements. It is of complete functions, friendly User Interface (UI), and easy operations, and can meet requirements by service activation and daily maintenance.
  • Page 56: Features

    NView NNM system. 4.2.2 Features The NView NNM system has the following features:  Work as the uniform platform for all manageable devices of Raisecom.  Uniformly manage data network and transport network. ...
  • Page 57: Ethernet Oam

    EFM is mainly the Ethernet links at the edge of access network. The RC1201-2GE16E1T1 supports EFM functions compatible with IEEE 802.3ah. It provides the following functions for two interconnected devices: ...
  • Page 59: Technical Specifications

     Security standards  Environmental requirements 5.1 Product specifications Table 5-1 lists the product specifications of the RC1201-2GE16E1T1. Table 5-1 Product specifications of the RC1201-2GE16E1T1 Technical specifications Description Dimensions (mm) 440 (Width) × 266 (Depth) × 44.45 (Height, 1 U) Weight (kg) 5.675...
  • Page 60: Component Specifications

    Raisecom RC1201-2GE16E1T1 Product Description 5 Technical specifications Technical specifications Description Frequency (Hz) 50/60 Ambient temperature (° C) 0–50 Humidity 10%–90% RH, non-condensation  1 KV in differentiated mode Lightning Power  2 KV in common mode protection level E1 interface 1.5 KV in common mode...
  • Page 61: Laser Security Class

    Gb/SS1 5.4 Laser security class According to the TX power of Laser, the RC1201-2GE16E1T1 laser belongs to Class 1 in security class. In Class 1, the maximum TX power on the optical interface is smaller than 10 dBm (10 mW).
  • Page 62: Emc Indexes

    Mean Time Between Failure 100,000 hours (MTBF) 5.6 EMC indexes The RC1201-2GE16E1T1, designed according to ETS 300 386 series and ETS 300 127 series of European Telecommunication Standards Institute (ETSI), has passed Electromagnetic Compatibility tests. 5.7 Security standards The RC1201-2GE16E1T1 complies with the following security standards: ...
  • Page 63: Table 5-7 Mechanical Active Substance Requirements During Storage

    No water dropping above  Away from any water leakage area, such as the automatical fire facility or central heating facility If the RC1201-2GE16E1T1 is kept outdoor, ensure the following four prerequisites:  The package box is intact.  Rainproof measures are taken that rain will not leak into the package box.
  • Page 64: Tranport Environment

    Raisecom RC1201-2GE16E1T1 Product Description 5 Technical specifications Table 5-8 lists chemical active substance requirements for the RC1201-2GE16E1T1 during storage. Table 5-8 Chemical active substance requirements during storage Chemical active substance Content ≤ 0.30 Sulfur dioxide SO (mg/m³ ) ≤ 0.10 Hydrogen sulfide H S (mg/m³...
  • Page 65: Operation Environment

    Reproduction of fungus and mould  Existence of rodent animals such as rats Air cleanliness No explosive, conductive, magnetic, and corrosive dust is around the RC1201-2GE16E1T1 during transportation. Table 5-10 lists mechanical active substance requirements for the RC1201-2GE16E1T1 during transportation.
  • Page 66: Table 5-12 Atmosphere Requirements During Operation

    Reproduction of fungus and mould  Existence of rodent animals such as rats Air cleanliness No explosive, conductive, magnetic, and corrosive dust is around the RC1201-2GE16E1T1 during transportation. Table 5-13 lists mechanical active substance requirements for the RC1201-2GE16E1T1 during operation.
  • Page 67: Table 5-14 Chemical Active Substance Requirements During Operation

    Raisecom RC1201-2GE16E1T1 Product Description 5 Technical specifications Table 5-14 Chemical active substance requirements during operation Chemical active substance Content ≤ 0.30 Sulfur dioxide SO (mg/m³ ) ≤ 0.10 Hydrogen sulfide H S (mg/m³ ) ≤ 3.00 Nitrogen dioxide NO (mg/m³ ) ≤...
  • Page 69: Installation

    Preparing for installation  Installation procedure  Check after installation 6.1 Installation location The RC1201-2GE16E1T1, a box of 1 U high, can be installed in the following scenarios:  ETSI 600-mm-deep cabinet  19-inch 450-mm-deep cabinet  19-inch 600-mm-deep cabinet ...
  • Page 70: Safety Statement

    Only qualified and authorized service personnel should carry out adjustment and installation. The device installation should comply with local safety specifications strictly. Safety matters mentioned in the manual is supplementary. Raisecom shall not be liable for the accident caused by violating general safety operation requirements and the safety standard of design, production and usage.
  • Page 71: Electrical Safety

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation 6.2.3 Electrical safety High voltage safety High voltage power supplies provide power for the operation, so direct contact or indirect contact through the wet object will lead to fatal danger. During installation, ensure the working environment and staff comply with high voltage safety rules to avoid personal injury and equipment damage.
  • Page 72: Radiation Safety

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation Electrostatic safety When contacting equipment or components, you must wear an ESD wrist. The ESD wrist should contact your skin, and insert the plug to ESD socket on the equipment. Avoid any contact between components and clothes because the ESD wrist cannot prevent the components from producing electrostatic when contacting with clothes.
  • Page 73: Mechanical Safety

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation  Do not the use of microscope, magnifier, loupe and other optical instruments to watch  Fiber connectors or the ends of fiber. Obey the following requirement for operations on optical fiber:  Only trained personnel can cut and weld optical fiber.
  • Page 74: Preparing Tools

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation 6.3.1 Preparing tools Table 6-2 lists tools to be prepared for installation. Table 6-2 Tools to be prepared for installation Name Picture Name Picture Tape measure: Level used to measure instrument: used the length...
  • Page 75 2 m signal transmission. Multi-meter: used to test the chassis insulation, cable connectivity and equipment electrical performance indicator. The RC1201-2GE16E1T1 is not equipped with these tools. Please prepare them yourself. Raisecom Technology Co., Ltd.
  • Page 76: Changing Installation Condition

    1000 V. Anti-seismic Up to eight-level seismic grade grade Power conditions Table 6-4 lists power conditions that the RC1201-2GE16E1T1 should comply with. Table 6-4 Power conditions Item Requirements AC power The AC rated voltage is 220 V with voltage fluctuation range 176–264 V.
  • Page 77: Checking Boxes

    Open box if the results of the above items are correct. Opening the chassis Stop opening the box immediately if the RC1201-2GE16E1T1 is found to be rusted or flooded in unpacking process. Provide feedback to the local Raisecom office after finding out reasons by customers and Raisecom engineers.
  • Page 78: Figure 6-1 Opening The Chassis

    Check the devices type and quantity according to the Packing List and sign to accept them face to face.  In case of wrong goods or less of goods phenomenon, please contact Raisecom engineers and customer to confirm and the relevant commissioner will replace goods or replenish goods for customers.
  • Page 79: Installation Procedure

     Protect the unpacking boxes and packaging materials well. 6.4 Installation procedure 6.4.1 Installation procedure The RC1201-2GE16E1T1 should be installed inside the room and fixed for use. Figure 6-2 shows installation process. Raisecom Technology Co., Ltd.
  • Page 80: Preparing For Installation

    You have already read Section 6.3 Preparing for installation.  You can meet requirements in Section 6.3 Preparing for installation. The RC1201-2GE16E1T1 may be damaged in transportation or by other reasons after leaving the factory, so power-on check before installation is recommended to avoid installing a faulty RC1201-2GE16E1T1.
  • Page 81: Installing The Chassis

    Installing the chassis to a rack Wear an ESD wrist grounded correctly when installing the chassis and components to prevent the chassis and components elements from damaging. If you plan to install the RC1201-2GE16E1T1 to a rack, choose appropriate rack according to Figure 6-3. ...
  • Page 82: Figure 6-4 Installing The Chassis To A Rack

    It is recommended that you install the device on a standard cabinet or open rack. If you plan to install the RC1201-2GE16E1T1 to the workbench, ensure the workbench complies with the following conditions: ...
  • Page 83: Connecting Grounding Cables

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation After selecting the appropriate workbench, place it steadily in the machine room in line with the following conditions:  The workbench environment is clean and tidy.  There is at least 30 cm space around the workbench to facilitate the device maintenance and heat dissipation.
  • Page 84: Figure 6-7 Grounding Terminal On The Rear Panel Of The Rc1201-2Ge16E1T1

    Figure 6-7. Figure 6-7 Grounding terminal on the rear panel of the RC1201-2GE16E1T1 Connect the earth point of rack or workbench to the earth socket in machine room properly no matter whether the chassis is installed on the rack or workbench.
  • Page 85: Connecting Power Cables

    1 Ω, then the protective grounding cable is installed correctly. Do not connect the grounding cable of the RC1201-2GE16E1T1 to water pipe or lightning rod of building, but connect it to the grounding terminal in the machine room.
  • Page 86: Connecting Service Cables

    (if installed) is off or the fuse is burnt out. 6.4.6 Connecting service cables The RC1201-2GE16E1T1 supports Ethernet cable, optical fiber and clock cable. The related interfaces in machine room should be installed completely before connecting service cables. Raisecom Technology Co., Ltd.
  • Page 87: Figure 6-12 Connecting The E1 Cable

    Connect the E1 cable as below: Step 1 Make E1 cables that are of proper length according to cabling path. Step 2 Connect the RJ45 connector of the E1 cable to the E1 interface on the RC1201-2GE16E1T1, as shown in Figure 6-12.
  • Page 88: Figure 6-13 Inserting The Sfp Optical Module

    To reduce the radiation injury, you must choose CLASS 1 optical module products in connecting optical fiber. Optical fiber is used to connect the RC1201-2GE16E1T1 and other devices, providing 1000 Mbit/s transmission rate. All connected fibers can be switched over through Optical Distribution Frame (ODF).
  • Page 89: Figure 6-14 Connecting Optical Fiber

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation Figure 6-14 Connecting optical fiber Connecting configuration cables Configuration port cable (also known as Console communication cable) is an 8-core shielded cable used to connect the device Console port to RS-232 serial port on computer and transmit device configuration data signals.
  • Page 90: Check After Installation

    Anti-static wrist is connected to the ESD jack on the rack. 6.5.3 Checking device After installation is complete, check that the RC1201-2GE16E1T1 is located steadily with enough space for heat dissipation, operation, and maintenance, and the grounding cable is correctly connected.
  • Page 91: Checking Cables

    Raisecom RC1201-2GE16E1T1 Product Description 6 Installation 6.5.4 Checking cables After installation is complete, check the RC1201-2GE16E1T1 as listed in Table 6-7. Table 6-7 Checking cables Item Requirement  The connection is correct and reliable. Power cable inside the rack, Power wire ground wire and signal line are laid separately;...
  • Page 93: Installing And Upgrading Software

    7 Installing and upgrading software Installing and upgrading software The RC1201-2GE16E1T1 is installed with all necessary software before delivery so that it can be powered on immediately after hardware installation is complete. The BootROM and system software can be installed and upgraded through Command Line Interface (CLI).
  • Page 94: Installing And Upgrading Nview Nnm Software

    RC1201-2GE16E1T1 Product Description 7 Installing and upgrading software You can upload system software and configuration file of the RC1201-2GE16E1T1 to the server through TFTP or FTP by executing the upload command, or download them to the RC1201-2GE16E1T1 by executing the download command.
  • Page 95: Appendix

    Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix Appendix This chapter includes the following section:  Mandatory standards and protocols  Terms  Acronyms and abbreviations 8.1 Mandatory standards and protocols  MEF Technical Specification MEF 6.1Ethernet Services Definitions - Phase 2 ...
  • Page 96: Terms

    Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix  ITU-T G.824 The control of jitter and wander within digital networks which are based on the 1544 kbit/s hierarchy  ITU-T G.825 The control of jitter and wander within digital networks which are based on synchronous digital hierarchy (SDH) ...
  • Page 97 Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix It provides a port association solution, extending link backup range. Transport fault of upper layer device quickly to downstream device by Failover monitoring upstream link and synchronize downstream link, then trigger switching between master and standby device and avoid traffic loss.
  • Page 98: Acronyms And Abbreviations

    Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix 8.3 Acronyms and abbreviations Numerics AAL1 ATM Adaptation Layer of type 1 AAL2 ATM Adaptation Layer of type 2 Attachment Circuit Associated Channel Access Control List Alarm Indication Signal Automatic Protection Switching Asynchronous Transfer Mode...
  • Page 99 Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix ECID Emulated Circuit Identifier Electromagnetic Compatibility Errored Second E-Tree Ethernet-Tree European Telecommunications Standards ETSI European Telecommunications Standards Institute Internet Protocol IPDV IP Packet Delay Variation IEEE Institute of Electrical and Electronics Engineers International Telecommunication Union - Telecommunication...
  • Page 100 Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix Network Node Management Operation, Administration and Maintenance Out Of Service Protocol Data Unit Provider Edge Packet Switched Network Packet Transport Network Permanent Virtual Circuit Pseudo Wire PWE3 Pseudo Wire Emulation Edge-to-Edge Quality of Service...
  • Page 101 Raisecom RC1201-2GE16E1T1 Product Description 8 Appendix Time Division Multiplex Type of Service Time to Live TDMoP Time Division Multiplex over Packet Unavailable Seconds User Network Interface Virtual Private Network Raisecom Technology Co., Ltd.
  • Page 103 Address Building 2, No. 28, Shangdi 6th Street, Haidian District, Beijing, P.R.China. Postal code: 100085 Tel: +86-10-82883305 Fax: 8610-82883056 http://www.raisecom.com Email: export@raisecom.com...

Table of Contents