UPPER TEMPERATURE LIMIT CONT'D
17. All values, features and defaults entered during the
calibration are now stored in memory and all Set Tip
Temperatures are turned "OFF". All Channel TIP
OFFSET CONSTANTs are set to the default value of "3"
for °C ("6" for °F).

TEMPERATURE SETBACK

The PRC 2000 system is equipped with a Temperature Setback feature which, when enabled, will preserve
tip life and reduce energy consumption.
ACTIVATION
There are two ways in which the system will enable the Temperature Setback feature.
1. AUTOMATIC OPERATION - The system memory can be programmed so that each Active
Channel will automatically and independently set back its Set Tip Temperature to 180°C (350°F)
after a selected period (10-90 minutes) of handpiece inactivity. See "Calibration" section for
details on programming this feature.
2. MANUAL OPERATION - The operator can manually force the system to place all Active
Channels in Temperature Setback by performing the following procedure.
a) Press and hold the Scroll Down Key.