Temperature Setback; Activation; Operation - Pace ST 85 Operation & Maintenance Manual

Table of Contents

Advertisement

Operation

Temperature Setback

To preserve tip life and save energy, the ST 85 system can be programmed to
automatically set back its Tip Temperature to 177°C (350°F) after a selected period of
handpiece inactivity (adjustable 10-90 minutes in Set-Up Mode). As received from
the factory, this feature is enabled. Refer to the "Set-Up Mode" section of this
manual to disable or adjust the time-out period of this feature. The operator can also
force the system into Temperature Setback.

Activation

There are two ways in which the system will activate the Temperature Setback feature.
1. Automatic Activation - The system memory can be programmed so that
the system will automatically activate Temperature Setback after a
selected period (10-90 minutes) of handpiece inactivity. See the "Set-Up
Mode" section for details on programming this feature.
2. Manual Activation - The operator can manually force the system to place
the system in Temperature Setback by performing the following
procedure.
a) Press and hold the Scroll Down (
b) Press the Scroll Up (
c) Release both keys.
Operation
Temperature Setback is indicated by the following.
1. The LED display will be flashing.
2. The Operating Temperature will stabilize at 177°C (350°F).