3. Set Upper Limit

Press the
UP and DOWN
SensaTemp handpieces. The Upper limit for TempWise handpieces is 850°F. Press and release the
PROGRAM Key
that an operator may work within. Setting a password will lock out unwanted changes to this feature.
4. Set Low Limit
Press the
UP and DOWN
SensaTemp handpieces. The Upper limit for TempWise handpieces is 500°F. Press and release the
PROGRAM Key
that an operator may work within. Setting a password will lock out unwanted changes to this feature.
Adjusting the working temperature below the set lower limit will turn power off to the selected channel.

5. SetBack Time

Choose one of the following:
a) Press and release the PROGRAM Key
time.
b) Press and release the Scroll
time. Press and release the PROGRAM Key
disabled by entering (00). The maximum set back time is 90 minutes.
c) Press and release the Scroll Down Key to decrease or enter "00" to disable the stored
Temperature Setback time. Press and release the PROGRAM Key
step.
The LED Display now shows the stored Temperature Setback time in minutes

6. Set Auto Off

Press the
UP Key to enter increase the auto-off time. When enabled, the Auto Off safety system of
the MBT 350 system turns off the power to the Handpiece 10- 90 minutes after entering Temperature
Setback. When the system has entered Temperature Setback, an Auto Off timer within the system
circuitry will start running if Auto Off is turned on. When Auto Off has activated, the LED Display will
blink "OFF". To disable the Auto-Off feature, enter "00". If any key is pressed during the selected time
out period, the Auto Off timer is reset. The system will return to normal operation. At the end of the
time out period, the system will enter Auto Off. Power is turned off to the heater and the LED Display
will show a flashing "OFF " and the LED indicator will turn red. Press and release the PROGRAM Key
to move to the next step.

7. Scan Enable / Disable

Press and release the Scroll
the scan feature of the MBT 350 scans each channel and display it's information individually for 3
seconds than continually repeats the order. Press and release the PROGRAM Key to move to the
next step.
©2005 PACE Inc., Annapolis Junction, Maryland All Rights Reserved
to set the upper temperature limit. 900°F is the upper limit for
to move to the next step. The upper limit feature will limit the temperature range
to set the upper temperature limit. 100°F is the upper limit for
to move to the next step. The lower limit feature will limit the temperature range
UP Key to enable or increase the stored Temperature Setback
UP Key to enable or disable the scan mode feature. When enabled
to keep the currently stored Temperature Setback
to proceed to the next step. Set back may be
to proceed to the next