Auto-Setback And Auto-Off Features; Tw 50 Tempwise System - Pace Sodr-Tek HEATWISE HW 50 Operation And Maintenance Manual

Hide thumbs Also See for Sodr-Tek HEATWISE HW 50:
Table of Contents

Advertisement

3. The LED indicator will turn amber while the tip is heating to the desired performance level.
4. Once the tip has reached the desired heat level, the LED indicator will turn green and the
system is ready to use.

Auto-Setback and Auto-Off Features

The HW 50 system comes standard with Auto-Setback and Auto-Off Features. These are pre-
programmed for 30 minute Setback and 30 minute Auto Off, which can be turned off by the switch on
the back of the unit. When Setback mode has been entered, the heat level will be adjusted to 3.5.
The following chart explains the function of the LED Indicator Light.
Power On
Normal Operation
Tip Cartridge Removed
Heater Open Sensor
System In SetBack
System in Auto-Off
System reactivated after Auto-Off
*The LED will be Amber or Green depending on the color when it entered Setback, or Auto Off.

TW 50 TempWise System

The TW 50 system is very easy to adjust and operate. The following instructions detail system
features and operation of the system.
Temperature Setback time, Auto Off) is contained in the "Programming Your System" portion of this
manual.
1. Ensure that the Set-Up procedure has been performed.
Verify the following:
a) Handpiece connection to the power source.
b) Proper tip installed in handpiece.
c) Power
appropriate
AC supply and the power source.
2. Turn the Power Switch On ("I").
display will begin to increase as the TD 100
handpiece heats up.
3. Press the Scroll Up
Temperature is now displayed, immediately perform step
4.
NOTE: If a Password has been previously programmed into the system, "EP" will be appear
on the LED Display at this point. When this message appears, the operator must
enter the correct Password before adjusting the temperature.
4. Adjust the temperature by pressing and holding Scroll Up
Observe the display as the Set Temperature increases first in increments of 5°, then in
increments of 10°. When the desired temperature is reached, release the key.
©2005 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
LED Indicator Activity
Information regarding changing of system options (e.g.,
cord
connection
between
Key.
The Set
Amber
Green
Green
Red
Red
Amber or Green*
Amber
Green*
LED
Indicator
Program/
an
Menu Button
The
Scroll Up/Down
Buttons
Key or Scroll Down
Page 8 of 17
key.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sodr-tek tempwise tw 508007-04258007-04268007-04568007-04578007-0458 ... Show all

Table of Contents