M/C Cable Downward - Epson C12 Series Manipulator Manual

6-axis robots
Hide thumbs Also See for C12 Series:
Table of Contents

Advertisement

Maintenance 3. Covers

3.11.2 M/C Cable Downward

■ Do not remove the connector plate forcibly. It may result in damage to the cables,
disconnection, and/or contact failure. These are extremely hazardous and may
result in electric shock and/or improper function of the robot system.
■ When installing the connector plate, be careful not to get the cables caught in it or
bend them forcibly to push into the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
CAUTION
and/or contact failure. These are extremely hazardous and may result in electric
shock and/or improper function of the robot system.
When routing the cables, check the cable locations at removing the connector
plate. Be sure to place the cables back to their original locations.
Removal
Remove the bolts and then remove the connector plate.
Installation
Install the connector plate to the Manipulator.
Hexagon socket head cap bolts: 8-M4×10
Tightening Torque: 4.0 ± 0.2 N·m
104
Hexagon socket head cap bolts: 8-M4×10
C12 Rev.3