Maintenance 5. Joint #1
6.
Remove the Joint #1 brake plate from the Joint #1 motor unit.
Hexagon socket head cap bolts: 3-M4×20
7.
Remove the Joint #1 motor unit from the base.
Hexagon socket head cap bolts: 3-M6×30 (with a plain washer)
Be careful not to tear and lose the heat radiation sheet attached to the motor.