It 1911I To Ma 200I; Commissioning - Leuze electronic 1910i Technical Description

2d-code hand-held scanner with rf transmission
Table of Contents

Advertisement

5.2 IT 1911i to MA 200i

RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF.
Required parts:
1x
50122434
1x
50122431
1x
50114517
1x
50123862
1x
50113397
1x
50112893
or
50112892
or
50112891
5.2.1

Commissioning

Open the MA 200i
Guide KB JST-HS-300 with the PG cable gland through the threaded hole and insert
the 12-pin JST connector
Connect the base station with the RS 232 cable
Connect the RS 232 cable to the 9-pin D-sub connector
Set the address using the address switch
Insert the field bus connection cable
Apply the voltage supply.
Please connect the base station acc. to the following figure.
Leuze electronic
IT 1911i ER-3
Base station IT 1911i
KB 232-1 IT 190x
Power supply unit
KB JST-HS-300
MA 204i
Profibus gateway
MA 208i
Ethernet gateway
MA 248i
Profinet gateway
IT1911i