Check Accumulator - Norwood Kwik-Till HSD2500 Operator's Manual

3-section drawn high speed disk
Table of Contents

Advertisement

ANNUALLY

Check Accumulator

1. Unfold the machine into the Field Position.
Till Folding & Unfolding" on page 4-11)
2. Lower the disks to the ground by retracting the Front
Wheel Cylinders A and Rear Roller Cylinders B .
(See Fig. # 5-40)
Fig. # 5-40 Lower Disks to the Ground
3. Relieve all the hydraulic pressure by placing the tractor
SCV levers to the FLOAT POSITION
running for the Main Frame Lift & Wing Fold cylinders.
4. The machine should now be in the "Field Lowered Po-
sition"
(See Fig. # 3-53)
WARNING
Only qualified and trained personnel should perform this
procedure. Always wear personal protective equipment.
WARNING
HIGH PRESSURE VESSEL
Avoid injury from high pressure escaping
hydraulic fluid.
• Relieve pressure from hydraulic system before
servicing
• Precharge with dry nitrogen gas only.
Failure to comply could result in serious injury or
death.
(See "Kwik-
A
B
with engine
.
5 - MAINTENANCE
5. The accumulator pressure should be checked annually.
6. Operational dry nitrogen pressure levels are between
700-800 psi (4826-5516 kPa) (48.3-55.2 bar). If levels
are below this range, recharge the accumulator with dry
nitrogen.
7. If pressure is 0 psi (0 kPa) (0 bar), replace the accumulator
due to an internal bladder rupture.
Always use dry inert gas (Dry Nitrogen - N2) for pre-
charging.
NEVER USE AIR OR OXYGEN, DUE TO THE DANGER
OF COMBUSTION / EXPLOSION
Fig. # 5-41 Nitrogen Check Port Location
5-29