Controller Display And Features; Icons - Graco ProBell Electrostatic Controller Instructions And Parts

Table of Contents

Advertisement

Controller Display and Features

Controller Display and Features
Screen Areas
There are five areas on the screen used for
numerical information. Six additional areas provide
non-numerical information.
Designation
Function
A1–A4
Displays actual values,
preset values, and system
parameters. Flashes when the
possible range is exceeded.
Displays Preset number, error
A5
diagnosis codes, and status
information.
A6
REMOTE operation enabled
A7
Electrostatics active/triggered
A8
System interlock connection
satisfied
38
A9
SAFE POSITION Interlock
satisfied
A10
24 VDC Interlock satisfied
A11
Electrostatic Enable input is
Active

Icons

Icon
Explanation
Electrostatic voltage (displayed
in kV)
Electrostatic current (displayed
in μA)
Electrostatics activate/trigger
REMOTE operation active.
Blinks when the keyboard lock is
active
System interlock satisfied
Display backlight illumination
(0–8)
Maintenance reminders
Static arc setting
Dynamic arc setting
One of the maintenance counters
has reached 0.
3A3657C

Advertisement

Table of Contents
loading

Table of Contents