Controller Connections

Connections

1. Connect the ground wire to the ground
connection (GG). Connect the other end to a true
earth ground. This connection is required for all
installations.
2. Connect the supplied controller input power cord
to the input power connection (DD) and secure
with the connector screw. This connection is
required for all installations.
Controller Input Power Connection
Controller
Pre-wired Power Cable Connection
Controller
Connector (F)
18
Pin No.
1
2
3
PE
Power Cord
Cable
Electrical Schematic for this cable:
The controller can operate at 100–240 VAC
(50–60 Hz). Connect the leads to a power
source according to local electrical codes. Pin
3 on the input power connection is the system
interlock. Pin 3 must have line voltage applied to
satisfy the system interlock. When the system
interlock pin is connected to line voltage, the
icon will appear on the controller. See
Screen Areas, page
3. Connect the 7-pin end of the power cable to the
applicator power cable connection (FF) on the
controller. Connect the 4–pin end of the power
cable to the rotary applicator. Follow instructions
in the rotary applicator manual. This connection
is required for all installations.
Function
Neutral conductor power supply
Phase (100-240 VAC)
System Interlock ON/OFF
(100-240 VAC) = ON
Grounding PE
Cable
38.
Wire Marking
1
2
3
Green/Yellow
Applicator
Power Supply Connector
3A3657C