Setup Screen 3 (Analog Input Type

Select)

Use Setup Screen 3 (Parameter P03) to select the
input signal type for the discrete I/O interface analog
inputs (Ai). Press buttons T5/T6 to change the
setting. The options are:
• 0 = VoLt: Analog voltage inputs are voltage type (0
- 10 V). This selection is the default.
• 1 = CUrr: Analog current inputs are current type
(4 - 20 mA).
This setting applies to Current Setpoint and Voltage
Setpoint analog inputs for the Discrete I/O interface.
See
Discrete I/O, page
20, for more information.
3A3657C
Setup Screen 4 (Analog Output Type
Select)
Use Setup Screen 4 (Parameter P04) to select the
output signal type for the discrete I/O interface analog
outputs (Ao). Press buttons T5/T6 to change the
setting. The options are:
• 0 = VoLt: Analog outputs are voltage type (0-10V).
This selection is the default.
• 1 = CUrr: Analog outputs are current type
(4-20mA).
This setting applies to Actual Spraying Current and
Actual Spraying Voltage analog outputs for the
discrete I/O interface. See
more information.
Setup
Discrete I/O, page
20, for
45