4. Connect the Discrete I/O cable to the Discrete
I/O cable connection (EE) on the controller. The
Discrete I/O cable is required for any installation
that involves integration. Two discrete I/O
interlock connections are supplied and must
be satisfied. (See
Interlocks, page 7
Discrete I/O, page
20, for a more detailed
explanation of each pin.
5. Connect the Graco CAN cables to the CAN
cable connections (HH) on the controller. CAN
communication is required for remote operation
with Graco modules to allow remote configuration
and operation of the controller.
NOTE: CAN communication is Graco proprietary
and will not work with other types of CAN.
Discrete I/O cable Connection
Controller
Cable
See
Discrete I/O, page 20
3A3657C
.) See
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
for more information.
NOTE: If CAN communication is used, connect
supplied ferrites to CAN cables near the
electrostatic controller (see below).
Function
Preset Select 1 Input
Preset Select 2 Input
Error Reset Input
Remote Enable/Disable Input
Electrostatics Enable Input
Safe-to-Move Output
Error Output
I/O Ground
Current Setpoint Input
Voltage Setpoint Input
Reserved Input
I/O Ground
Actual Spraying Current Output
Actual Spraying Voltage Output
Electrostatics Discharged Output
Output External Power (24 VDC)
I/O Ground
SAFE POSITION Interlock Input
24 VDC Interlock Input
Controller Connections
Wire Color
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
Black
Purple
Gray/Pink
Red/Blue
White/Green
Brown/Green
White/Yellow
Yellow/Brown
White/Gray
Gray/Brown
Pink/Brown
and
Pink/White
19