Standby Mode

Standby mode is when the electrostatics are off
because the system is not ready to perform a
spraying operation. During standby mode, the
following conditions may exist:
• The system is powered down
• Fluid is being loaded
The controller deactivates the electrostatics (if
electrostatics are activated), or prevents the
electrostatics from being activated, when any or a
combination of the following signals are inactive:
Standby Timing Diagram
System Interlock Input
24 VDC Interlock Input
SAFE POSITION Interlock Input
Electrostatic Enable Input
Electrostatics
: = Input
: = Output
3A3657C
Operation Modes and Timing Diagrams
• System interlock (power connector)
• 24 VDC Interlock
• Electrostatic Enable
NOTE: The SAFE POSITION input does not
deactivate electrostatics if they are already on. The
SAFE POSITION input only prevents electrostatics
from being activated.
All input signals shown here must be active
for the controller to enable electrostatics. See
Signals, page