Operation

Operation

System Start-up

Press on to turn on the controller. The controller
always starts up to the last configured settings.
The controller has two sets of screens, Run and
Setup. This section includes information on the Run
screens, used to operate the electrostatic applicator.
See
Setup Screens, page
completed initial setup.
Press and hold
to toggle between the Run
screens and the Setup screens.
NOTE: When viewing Run Screens, after 5 seconds
have elapsed since the last keystroke, the display will
revert to Run Screen 1.
50
41, If you have not yet

Presets

The Electrostatic Controller has 251 (P000-P250)
user-defined Presets. There are four values
associated with each Preset. These are:
• Voltage setpoint
• Current setpoint
• Static arc limit
• Dynamic arc limit
Voltage and current setpoints are specified on
Run Screen 1 (Electrostatic Readings), page
Arc limits are specified on
Run Screen 2 (Arc Limits), page
NOTE: Only Presets P000-P003 are accessible
through the discrete I/O interface. The CAN interface
runs in preset P000 only. All Presets (P000-P250)
are accessible in local mode.
51.
52.
3A3657C