1.2

HV-2000C Controller Specifications

PARAMETER
Size
Drop Parameters
Recipes
Nozzle Heater
First Drop Compensation
Interface
Input/Output
Operating Temperature
Input Pressure
Input Power
Advanjet Software
Approvals
1.3

Technical Assistance

For technical assistance:
Phone:
+1 760-294-3392
Web:
www.advanjet.com
E-mail:
info@advanjet.com
3A5856A
SPECIFICATION
Width: 254.0 mm (10.00 in)
Height: 152.5 mm (6.00 in)
Depth: 341.4 mm (13.44 in)
Weight: 3200 g (7.05 lbs)
Refill time and Dwell (0.1 msec resolution)
Number of drops (programmable from 1 to 1M)
6 independent recipes, manual or remote triggers
Heating to 70 C Max
± 1.0 C @ 50 C
PID control using platinum RTD, Auto tuning
24 VDC, 5.7 W, 100 Ω
Programmable shutoff timer
2 alarms for process control
2 levels with programmable time interval
RS-232 Serial Port
LCD Display with Keypad
TTL level triggers
15 °C to 50 °C (59 °F to 122 °F)
0.6 MPa (90 psi) - maximum
100 – 240 VAC, 50/60 Hz, 115 W
Fuse: 5x20 mm, Fast-acting, 1.6 amp, 250 VAC
Windows XP, Vista, Windows 7 and Windows 8