Troubleshooting; Error Codes - Graco ProBell Electrostatic Controller Instructions And Parts

Table of Contents

Advertisement

Troubleshooting

Error Codes

The Electrostatic Controller is monitored constantly. If a error is detected, an error message is indicated
with a error code.
The error codes are shown in red on the A5 display.
The four most recent error codes are stored by the order of their appearance. Each error in the list must be
acknowledged with the
The table below shows all possible error codes for the Electrostatic Controller.
Code
Description
Electrostatics
H11
Applicator
Failure
H12
High Voltage
Overvoltage
H13
Applicator
Supply
Overvoltage
H15
Arc detection
static limit
H16
Arc detection
dynamic limit
3A3657C
key. If an error code is shown, the
Criteria
The controller does not detect
a current from the applicator, or
detects a current that is too low.
Measured voltage output is
greater than 105 kV.
Applicator voltage is too high.
The static arc detection
threshold is exceeded. A
grounded object came too
close to the applicator.
Dynamic arc detection
threshold exceeded. A
grounded object approached
the applicator at too high of a
speed.
key cannot be used for other functions
Controller
Solution
Action
Stop
• Verify applicator power
cable connection, perform
Power Cable Continuity, page
replace cable if needed.
• Replace applicator power cable or
applicator power supply if needed.
Stop
• Verify system grounding.
• Verify applicator power cable
connection and perform
Power Cable Continuity, page
• Replace applicator power cable or
applicator power supply if needed.
Stop
• Verify applicator power
cable connection, perform
Power Cable Continuity, page
replace cable if needed.
• Replace applicator power cable or
applicator power supply if needed.
Stop
• Verify closest distances to parts.
• Verify paint conductivity.
• Verify spraying parameters associated
with static arc detection, see
Run Screen 2 (Arc Limits), page
Stop
• Verify fastest approach to parts.
• Verify paint conductivity.
• Verify spraying parameters associated
with dynamic arc detection, see
Run Screen 2 (Arc Limits), page
Troubleshooting
64, and
64.
64, and
52.
52.
61