Analog Inputs; Analog Outputs - Graco ProBell Electrostatic Controller Instructions And Parts

Table of Contents

Advertisement

Analog Inputs

The analog inputs are used to set certain parameters
remotely by a PLC. The inputs can be configured
to be either voltage or current inputs. This setting
applies to all inputs simultaneously.
Electrical Specifications
Use Parameter P03 (See
Setup Screen 3 (Analog Input Type Select), page
to select the input signal type.
Voltage input mode, P03 = 0
Parameter
Nominal input range
Input impedance
Maximum allowed input
voltage
Reverse polarity
protection
Accuracy
Recommended source
impedance
Current input mode, P03 = 1
Parameter
Nominal input range
Input impedance
Maximum allowed input
voltage
Reverse polarity
protection
Input current limit
Accuracy
3A3657C
45)
Value
0 – 10 VDC
4.7 kΩ
30 VDC
Yes
1% typical
< 10 Ω
Value
4 – 20 mA (sinking)
100 Ω
30 V
Yes
Yes, 25 mA
1% typical

Analog Outputs

The analog outputs are used to communicate
actual values to other devices, such as a PLC. The
outputs can be configured to be either voltage or
current outputs. This setting applies to all outputs
simultaneously. The analog outputs require an
external 24 VDC voltage to be connected to Output
External Power (discrete I/O interface, pin 16).
Electrical Specifications
Use Parameter P04 (See
Output Type Select), page
signal type.
Voltage output mode, P04 = 0
Parameter
Output voltage range
Output impedance
Short circuit protection
Accuracy
Current output mode, P04 = 1
Parameter
Output current range
Output impedance
Short circuit protection
Accuracy
Maximum load
resistance
Minimum load resistance 0 Ω (0–20 VDC)
Discrete I/O
Setup Screen 4 (Analog
45) to select the output
Value
0 – 10 VDC
< 10 Ω (sourcing)
0 – 30 VDC
1% typical
Value
4 – 20 mA
< 10 Ω (sourcing)
0 – 30 V
1% typical
1 kΩ (0–20 VDC)
25