Operation

Run Mode

The controller is in Run Mode providing the following cir-
cumstances are present:
The controller is not in SETUP MODE.
An Alarm is not active.
Timer Mode: Pump ON
The display indicates the amount of time remaining in
the pump cycle, counting down the Pump ON time value
(see Time Control (on:ti) ON Setup, page 7).
The Pump output is enabled.
Pump ON time is shown in MM:SS (minutes:sec-
onds).
Timer Mode: Pump OFF
The display indicates the amount of time remaining in
the pump OFF cycle, counting down the Pump OFF time
value (see Programming OFF Time Duration, page 8).
The Time OFF LED illuminates and the pump output
is disabled during the Pump OFF time.
Pump OFF time is shown in HH:MM (hours:minutes)
or MM:SS if the time remaining is less than an hour.
334662B

Test Mode

To enter Test Mode:
1. Press the LEFT and
RIGHT ARROW
buttons together for
3 seconds.
2. The unit will cycle ON for 45 seconds and OFF for
15 seconds until the Test Mode is exited.
3. To exit Test Mode, press the Reset
button once.
Setup