Conversion Of The Cpa Valve Terminal To Different Pressure Zones - Festo CPA VI Series Manual

Compact performance valve terminal pneumatics
Hide thumbs Also See for CPA VI Series:
Table of Contents

Advertisement

5. Maintenance and conversion
5.4.3 Conversion of the CPA valve terminal to different pressure
zones
5-20
In order to convert the CPA valve terminal to two press-
ure zones, you will require the following components:
– a sub-base with pressure zone separation
CPA10-AW-ZP or CPA14-AW-ZP
For every further pressure zone you will also require:
– a sub-base with pressure zone separation
– an additional pressure supply plate CPA10-DP-U-AW
or CPA14-DP-U-AW
In the case of CPA valve terminals with MP, CP or AS-i
connection we recommend that the conversion be car-
ried out from the right hand side. The tie rod screws are
more easily acccessible on the right hand end plate.
The method of replacing the sub-bases and fitting the
additional pressure supply plate is described under "Re-
placing the end plate, sub-base or manifold block" or
"Replacing the reserve plate or additional pressure sup-
ply plate" in this chapter.
CPA... 9808A

Advertisement

Table of Contents
loading