Festo CPA VI Series Manual page 93

Compact performance valve terminal pneumatics
Hide thumbs Also See for CPA VI Series:
Table of Contents

Advertisement

5. Maintenance and conversion
)
Number*
Starting basis: valve terminals
with an even number of valve
locations
+ 1
2 long tie rod screws
+ 2
2 tie rod extensions
+ 3
2 tie rod extensions and
2 long tie rod screws
> + 3
2 basis tie rods or
2 long tie rod screws
)
*
number of valve locations to be added
CPA... 9808A
Components for adding valve locations
You will require:
Components
Sub-base
or
sub-base for separation of pressure zones
Manifold plate (single solenoid valve location)
or
valve plate (double solenoid valve)
Basis tie rod
(graduation: 2, 4, 6 to 22)
If necessary, tie rod extension (for 2 additional
valve locations)
If necessary, short tie rod screw (for valve termi-
nals with an even number of valve locations)
Long tie rod screw (for valve terminals with an
odd number of valve locations)
The table below shows the tie rod components which
you will require for adding valve locations.
Starting basis: valve terminals
with an odd number of valve
locations
2 tie rod extensions and
2 short tie rod screws
2 tie rod extensions
2 basis tie rods and
2 short tie rod screws
2 basis tie rods or
2 short tie rod screws
Typ
CPA..-AW
CPA..-AW-ZP
CPA..-EV1
CPA..-EV2
CPA..-ZA-2
.
.
CPA..-ZA-22
CPA..-ZA-2Z
CPA..-ZA-SK
CPA..-ZA-SL
5-25