3. Installation
3-4
Basic instructions
– Connecting
1. Push tube (B) as far as possible into the tube
of the pin-type connectoror into the screw
connector. If necessary, press down locking
ring (A).
2. Group the tubing together for a clearer overview
of the system using either:
- tube straps or
- multiple hose holders
– Disconnecting
1. Press down the locking ring (A) of the Pin-type
connector or of the screw connector.
2. Pull out tube (B).
3. Seal non-required connections with blind plugs
or threaded blind plugs (C).
Connecting
Disconnecting
Pin-txpe connector
!
Pin-type adapter
QS screw connector
Fig. 3/1: Tubing variants
(A)
!
(C)
(B)
CPA... 9808A