5. Maintenance and conversion
)
Number*
Starting basis: valve terminals
with an even number of valve
locations
- 1
2 basis tie rods and
2 long tie rod screws
- 2
2 basis tie rods
- 3
2 basis tie rods and
2 long tie rod screws
> - 3
2 basis tie rods or.
2 long tie rod screws
)
*
number of valve locations to be removed
5-26
Components for removing valve locations
When valve locations are removed, the tie rods must
be adapted accordingly.
You will require:
Components
Basis tie rod
(graduation: 2, 4, 6 to 22)
If necessary, short tie rod screw (for valve termi-
nals with an even number of valve locations)
Long tie rod screw (for valve terminals with an
odd number of valve locations)
The table below shows the tie rod components which
you will require to adapt the length of the tie rod.
Starting basis: valve terminals
with an odd number of valve
locations
2 short tie rod screws
2 basis tie rods
2 basis tie rods and
2 short tie rod screws
2 basis tie rods or
2 short tie rod screws
Typ
CPA..-ZA-2
.
.
CPA..-ZA-22
CPA..-ZA-SK
CPA..-ZA-SL
CPA... 9808A