Convotherm 4 Series Installation Manual page 99

Combi oven
Table of Contents

Advertisement

6 Installation
Installing the water supply
1.
2.
3.
4.
5.
6.
7.
8.
Flush through the customer's water supply pipe (Z).
Fit the sediment filter (X) and, if necessary, a water treat‐
ment system (W).
Fit a separate shut-off device (Y) for each appliance.
If a backflow preventer (V) or double check valve (DCV)
are required (see connection diagram), fit the relevant de‐
vice in the water supply line.
Connect the appliance as shown in the connection draw‐
ing.
Flush through the sediment filter by operating the recoil
hand shower.
Once the water supply has been installed, close the shut-
off device.
Inform the user about the service intervals for the filters,
and the water treatment system if applicable.
99