4 Option Components
Table 4.1 Male 8-way Ethernet Modular Connector (Customer-Supplied)
Male EtherNet 8-Way Modular Connector
*1
Not used for 10 Mbps and 100 Mbps networks.

Option LED States

The option has four LEDs:
• Bi-color Status LEDs:
– Module status (MS) red/green
– Network status (NS) red/green
• Ethernet LEDs (2 each):
– Network speed-10/100 yellow
– Link status and network activity-Link/Act green
A - 1000-Series
B - GA500, GA700, GA800, CR700, and CH700
*1
LED label has transparent background and white letters. Please make sure that you use the correct label for HV600.
Wait 2 seconds minimum for the power-up diagnostic process to complete before you verify the LED states. The
operational status of the option LEDs after the power-up diagnostic LED sequence is complete are described in
Table
4.2. The statuses with a number in parenthesis are the number of pulses of 250 ms ON and 250 ms OFF.
When pulses of ON and OFF are completed for the number of times, LED will be 500 ms OFF, then repeat the
cycle of ON and OFF for the number of times.
Refer to
Table 4.3
for more information about the LEDs.
LED Name
MS (visible through drive cover)
10
Figure 4.2 Option LED Labels
Table 4.2 Option LED States
Indication
Color
Status
-
OFF
Green
ON
Green
Flashing (1)
Green
Flashing (2)
Red
ON
Red
Flashing (1)
Red
Flashing (2)
Red
Flashing (3)
Pin
1 (Pair 2)
2 (Pair 2)
3 (Pair 3)
4 (Pair 1)
5 (Pair 1)
6 (Pair 3)
7 (Pair 4)
8 (Pair 4)
C - HV600
*1
Operating Status
Power supply off
Option operating
Diagnostics
Configuration tool
Default MAC or fatal error occurred.
Invalid Station Name programmed
No IP (non-fatal)
No station name (non-fatal)
YASKAWA SIEP C730600 89E PROFINET Technical Manual
Description
Transmit data (TXD) +
Transmit data (TXD) -
Receive data (RXD) +
*1
Not used 
*1
Not used 
Receive data (RXD) -
*1
Not used 
*1
Not used 
Description
There is no power to the drive.
The option is operating normally and
initialization is complete.
Diagnostic data available.
Identified by a configuration tool.
The default MAC address is programmed
or the option detected an unrecoverable
error.
The device has an invalid Station name.
You must use a valid station name from the
PLC software or web page and rewrite it.