DS-77xxNXI-I4/16P/4S NVR User Manual
NUCLEUS − Click Custom to configure the NUCLEUS settings. Enter the employee no. shift no. and the
terminal no. in the field. The matching message sent from the POS device will be used as the valid POS
data.
NUCLEUS protocol must be used for RS-232 connection communication.
6. Set the connection mode to TCP Connection, UDP Connection, Multicast, RS-232, USB-to-RS-232, or
Sniff, and click Parameters to configure the parameters for each connection mode.
TCP Connection
1) When using TCP Connection, the port must be set from 1 to 65535, and the port for each POS
machine must be unique.
2) Set the Allowed Remote IP Address of the device sending the POS message.
UDP Connection
1) When using a UDP connection, the port must be set from 1 to 65535, and the port for
each POS machine must be unique.
2) Set the Allowed Remote IP Address of the device sending the POS message.
USB-to-RS-232 Connection − Configure the USB-to-RS-232 convertor port parameters, including the
port serial number, baud rate, data bit, stop bit, parity, and flow ctrl.
UM DS-77xxNXI-I4/16P/4S 050619NA
Figure 15-4 TCP Connection Settings
139